Rectal Spacer for Prostate Cancer Radiation Image Guidance

NCT ID: NCT05650021

Last Updated: 2025-12-09

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

17 participants

Study Classification

INTERVENTIONAL

Study Start Date

2024-03-08

Study Completion Date

2025-09-15

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of the study is to determine if a radiopaque hydrogel rectal spacer, SpaceOAR Vue®, can be used in place of fiducial markers when aligning patients for radiotherapy. The investigator hypothesizes that the alignment of the patient based on the rectal spacer will be similar to the alignment of the patient with fiducial markers.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

In 2021 it is estimated that there will be 248,530 new cases of prostate cancer. Treatment options for prostate cancer are broad and based primarily on the risk category of prostate cancer as well as the life expectancy of the patient. For patients with intermediate and high-risk prostate cancer, there are a multitude of treatment options including radical prostatectomy, external beam radiation, brachytherapy, a combination of external beam and brachytherapy, and with strong consideration of androgen deprivation therapy (ADT) for patients receiving radiation who have higher risk disease. Furthermore, external beam radiotherapy can be delivered in a variety of dose / fractionation schedules, such as conventionally fractionated courses over 8-9 weeks, moderately hypofractionationed courses over 4-6 weeks, and stereotactic body radiation therapy (SBRT) over just 5 treatments. Since the prostate location is variable and dependent on rectal and bladder filling, on any given treatment day the prostate may shift \> 1cm relative to bony anatomy. A current state of the art image guided radiotherapy (IGRT) includes the use of cone beam CT (CBCT) for alignment of the prostate based on internal 3D anatomy. Since this technology lacks soft tissue contrast, the implantation of at least three non-colinear fiducial markers in the prostate is commonly utilized to help with daily IGRT to reproducibly align the prostate for radiotherapy. The use of three fiducials ensures that alignment of the three points at the time of CBCT accurately triangulates the location of the prostate gland in three-dimensional space.

Another major advance prostate radiotherapy is the use of rectal hydrogel spacer to displace the anterior rectal wall posteriorly away from the high doses of radiation prescribed to the prostate. A phase III trial of hydrogel rectal spacer during prostate radiotherapy found decreased toxicity and improved bowel quality of life at 3 years for patients receiving the spacer. Subsequently, the device (SpaceOAR®) was FDA approved in April 2015. The first generation of spaceOAR® is only discernable on MRI, which most commonly necessitates a prostate MRI after placement to assist with radiotherapy planning. The second generation of SpaceOAR®, deemed SpaceOAR Vue ®, is an iodinated version of the hydrogel that is visible on CT scan and thus obviates the need for a post-procedural MRI scan for radiotherapy treatment planning. In July 2019 the SpaceOAR Vue® device received 510(k) clearance indicating that it is substantially equivalent to predicate devices and can thus be marketed for use in the United States. SpaceOAR Vue® is now offered to patients with prostate cancer undergoing radiotherapy to decrease rectal toxicity.

The placement of fiducial markers and rectal hydrogel spacers are relatively well tolerated, though they are both still invasive procedures that carry a small, but tangible amount of risk due to transperineal or transrectal needle placement. Approximately 1/3 of patients will have at least one new symptom after fiducial marker placement, most commonly increased urinary frequency, hematuria, rectal bleeding, dysuria, hematospermia, pain, obstruction, or fever. Most of these side effects are grade 2, though 0.5-1.5% of patients have been shown to have a grade 3 complication from fiducial marker placement. With placement of rectal hydrogel, mild transient procedural adverse events such as perineal discomfort was noted in 10% of patients receiving spaceOAR. The investigator proposes that SpaceOAR Vue® may be used not only as a radiopaque rectal spacer, but also as a three-dimensional fiducial marker. This would obviate the need for fiducial marker placement resulting in improved patient experience, less procedural invasiveness, and decreased procedural toxicity.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Prostate Cancer

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

SpaceOAR Vue and fiducial marker

After enrollment, patients will be treated per the standard of care, including the use of daily CBCT for image guided radiotherapy. The investigator will review the CBCT on the first day of treatment and align in such a way that the fiducials match up but also that the radio-opaque SpaceOAR lines up to within 5mm. If the SpaceOAR does not line up to within 5mm, the investigator will consider an intervention such as having the patient get off the table to pass gas, have a bowel movement, additional counseling about diet and bowel movement habits, or potentially even re-simulation. These daily CBCT images are aligned to the CT simulation images by way of aligning the fiducial markers on the respective imaging data sets. The CBCT images acquired during their first five fractions of radiotherapy will be imported into MIM software.

Group Type OTHER

SpaceOAR Vue

Intervention Type DEVICE

CBCT images acquired during the first five fractions of radiotherapy

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

SpaceOAR Vue

CBCT images acquired during the first five fractions of radiotherapy

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Fiducial marker

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* To be eligible for the study, you must have already had SpaceOAR and fiducial markers placed before undergoing prostate radiotherapy, or you should have a plan to have them placed.
* Untreated cT1 - cT3 prostate cancer

Exclusion Criteria

* Extracapsular extension of prostate cancer
* Prior prostatectomy
Eligible Sex

MALE

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Milton S. Hershey Medical Center

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Joseph Miccio

Assistant Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Joseph Miccio, MD

Role: PRINCIPAL_INVESTIGATOR

Penn State Caner Institute

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Penn State Cancer Institute

Hershey, Pennsylvania, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

PSCI-21-158

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

SpaceIT Hydrogel System for Perirectal Spacing
NCT06451614 ACTIVE_NOT_RECRUITING NA