Prostate-Rectal Separation With PEG Hydrogel and Its Effect on Decreasing Rectal Dose
NCT ID: NCT02212548
Last Updated: 2021-06-14
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
30 participants
INTERVENTIONAL
2012-03-31
2016-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Rectal Spacer Hydrogel Before Radiation Therapy in Reducing Radiation Dose to the Rectum in Patients With Prostate Cancer
NCT05224869
Using Rectal Hydrogel Spacer for Salvage SABR in Prostate Cancer
NCT05597852
Post-marketing Surveillance Regarding Efficacy and Safety of SpaceOARâ„¢
NCT01999660
Rectal Spacer for Prostate Cancer Radiation Image Guidance
NCT05650021
Rectal Spacers in Prostate Cancer Patients Undergoing Radiation Therapy
NCT06599476
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
In order to compare the effect of the PEG hydrogel (SpaceOAR) on the dose of radiation received by the rectum, two radiotherapy plans will be created. One planning CT scan will therefore be performed prior to the injection of the PEG hydrogel and one one week following injection of the hydrogel. The two treatment plans will be created by the same radiation therapist.
As the hydrogel is clearly visible on MRI and not on CT scans, we will obtain a pelvic MRI scan following injection of the hydrogel.. The MRI scans will be used in planning and fused to the planning CT scans to aid voluming.
Treatment:
Patients will undergo standard prostate cancer planning and treatment using image guided dose escalated IMRT as per the RNSH Department protocol and guidelines to a dose of 80Gy in 40 fractions 14.
Rectal Dose Analysis:
Two plans with dose-volume histograms will be created, one using the planning CT scan from prior to the PEG hydrogel (SpaceOAR) injection and one using the planning CT and MRI performed one week post hydrogel injection. MRI scans will be obtained on the same day as the CT simulation using the same bladder filling and rectal emptying protocols. Each patient will have two plans created by the same Radiation Therapist. This will allow for comparison between the 2 plans. The patient will be treated according to the post PEG hydrogel injection plan, with the initial plan for comparison purposes only. The volume of rectum receiving 80Gy, 75Gy, 70Gy, 65Gy, 60Gy, 40Gy, 35Gy and 25Gy will be compared with the two plans.
Patient assessment:
Patients will be assessed immediately post injection of the hydrogel, 24hrs later by telephone and 1 week later by telephone to determine if there has been any adverse event related to the PEG hydrogel (SpaceOAR) injection. This will include questions regarding pain or discomfort, infection, bleeding, and changes in bowel or bladder function. Information about every adverse event will be collected and recorded on the appropriate case report form. Adverse events will be described by duration (start and end dates), severity grade, and action taken. A follow-up report will follow the initial report within 5 working days. Any reports where the adverse event has not resolved at this time will be followed up to resolution of the event or until it becomes chronic and a statement is made to this effect.
During radiotherapy treatment patients will be assessed weekly in the clinic and their toxicity will be recorded using the modified RTOG and National Cancer Institute Common Terminology Criteria (v4.0) for adverse events.
Patients will be reviewed in the clinic 3 months, 9 months, 15 months and 21 months post completion of treatment and rectal toxicity will be assessed using the modified RTOG and National Cancer Institute Common Terminology Criteria (v4.0) for adverse events.
Adverse events:
An adverse event is any undesirable experience associated with the use of a medical product in a patient. All adverse events will be appropriately reported by duration (start and end dates), severity grade, and action taken on the appropriate case report form.
Grade 1 or mild events are easily tolerated. Grade 2 or moderate events cause enough discomfort to interfere with usual activity.
Grade 3 or severe events result in inability to carry out usual activities. Grade 4 events are life threatening or disabling. The serious adverse event will be documented and medically assessed by the investigator. As the PEG hydrogel cannot be removed following injection, patients will be treated medically and symptomatically. A follow-up report will follow the initial report within 5 working days. Any reports where the adverse event has not resolved at this time will be followed up to resolution of the event or until it becomes chronic and a statement is made to this effect.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Hydrogel
The patient will be in the dorsal lithotomy position and prepared and draped. A transrectal ultrasound (TRUS) will be used for alignment of the needle and to ensure safe delivery. The hydrogel precursor and accelerator solutions will be mixed and connected to the Y connector that has been flushed with saline and to a syringe holder that ensures both syringe barrels are injected at the same time. After aspirating to ensure the tip of the needle is not intravascular, the perirectal space will be adequately dissected from the apex to midgland by injecting saline into the space between denonvilliers fascia and the anterior rectal space under TRUS guidance. Maintaining the needle position and angulation, the saline syringe is disconnected and the hydrogel system connected. After aspirating to ensure the needle tip is not in a blood vessel and under TRUS guidance, the 'PEG Hydrogel (SpaceOAR) is injected in a smooth, continuous technique.
PEG Hydrogel (SpaceOAR)
A single injection of PEG hydrogel (SpaceOAR) through the perineum under transrectal ultrasound guidance while under general anaesthetic.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
PEG Hydrogel (SpaceOAR)
A single injection of PEG hydrogel (SpaceOAR) through the perineum under transrectal ultrasound guidance while under general anaesthetic.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Eligible for prostate radiotherapy, either for definitive treatment or to aid local control in patients with known metastatic disease.
Exclusion Criteria
2. Complications following prostate biopsy including infection
3. Urinary retention symptoms
4. Bleeding disorder
5. Renal impairment
6. Anal fistula or perianal abscess
MALE
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Royal North Shore Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Professor Thomas Eade
Dr.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Thomas Eade, MD
Role: PRINCIPAL_INVESTIGATOR
Royal North Shore Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Northern Sydney Cancer Centre, Royal North Shore Hospital
St Leonards, New South Wales, Australia
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Juneja P, Kneebone A, Booth JT, Thwaites DI, Kaur R, Colvill E, Ng JA, Keall PJ, Eade T. Prostate motion during radiotherapy of prostate cancer patients with and without application of a hydrogel spacer: a comparative study. Radiat Oncol. 2015 Oct 24;10:215. doi: 10.1186/s13014-015-0526-1.
van Gysen K, Kneebone A, Alfieri F, Guo L, Eade T. Feasibility of and rectal dosimetry improvement with the use of SpaceOAR(R) hydrogel for dose-escalated prostate cancer radiotherapy. J Med Imaging Radiat Oncol. 2014 Aug;58(4):511-6. doi: 10.1111/1754-9485.12152. Epub 2014 Mar 3.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Hydrogel
Identifier Type: -
Identifier Source: org_study_id