Conventional Instrumentation, Computer Navigation, and Robotic Assistance Techniques in TKA
NCT ID: NCT05629715
Last Updated: 2024-08-13
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
WITHDRAWN
NA
INTERVENTIONAL
2025-06-01
2027-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Advanced techniques that utilize computer navigation or robotic-arm assistance have been developed in an attempt to avoid malalignment. Both technologies were created with the goal of improving the precision of implant positioning and implant sizing in order to improve lower limb alignment and joint line alignment. The OrthoAlign KneeAlign computer assisted navigation system is a commercially available device that uses gyroscopic limb position sensing technology mounted to intramedullary and extramedullary jigs to measure bone resection cuts in TKA that ultimately dictate implant position. The Zimmer Biomet ROSA Knee System is a commercially available, FDA-approved robotic assistant for performing TKA. It uses pre-operative x-rays to create a three-dimensional image of the patient's knee anatomy, which is used to create a pre-operative template of the implants to be used and provides intra-operative guidance for bone cuts during the TKA. The robotic system also assesses the soft tissue envelope around the knee and can assist with the soft tissue balancing of the knee arthroplasty. Alternatively, it can also be used in an imageless mode where bone cuts are performed based on intra-operative mapping using anatomic landmarks. To date, there have been no prospective studies comparing the implant positioning and patient outcomes directly of the KneeAlign system with the ROSA system and conventional TKA instrumentation techniques.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Surgical Outcomes of the Accelerometer-based Navigation System for Total Knee Arthroplasty
NCT04037228
Navio With Total Knee Arthroplasty
NCT03317834
Application of Computer-assisted Navigation in Total Knee Arthroplasty: A Randomized Pair-matched Double-blind Trial
NCT00982956
Prospective Clinical Study Evaluating Tibiofemoral Rotational Alignment Using Intraoperative Sensing During Total Knee Arthroplasty (TKA)
NCT02286739
Study to Evaluate Patient Outcomes and Safety and Effectiveness of Robotic Assisted Unicompartmental Knee Replacements Versus Conventional Unicompartmental Knee for Subjects With Primary Arthritis of the Knee Joint Involving One (UKA) Compartment (Medial or Lateral)
NCT06036212
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The primary objective of this study is to collect and compare clinical and surgical data using the commercially available ROSA Knee System instrumentation or OrthAlign KneeAlign system compared with conventional TKA instrumentation. The hypothesis is that the ROSA Knee System and KneeAlign system will demonstrate greater accuracy and more consistent component position and greater patient reported outcome scores compared to conventional TKA surgery. The investigators suspect that the ROSA system may be more accurate and precise than the KneeAlign system.
A maximum of 300 subjects in each arm (900 total) are to be enrolled in this study. In order to minimize selection bias, the investigator will randomize the instrumentation technique used. Randomization will be accomplished via a random number generator in a 1:1:1 ratio. The subject will know which treatment arm they are in at the time of study consent. They will be ineligible for the study if they ask to change treatment arms. The Principal Investigator and Co-Investigators will be skilled in TKA and experienced implanting Persona or Legion TKA system. Two of the investigators will only be using the Persona TKA system as this is their current standard of practice. One of the other investigators will use the Legion TKA system as this is their standard of practice. In order to avoid potential selection bias, each investigator will offer study participation to each consecutive eligible patient presenting as a candidate for primary TKA using the aforementioned implants. All study subjects will undergo preoperative clinical evaluations prior to their TKA.
An a priori power analysis was conducted using G\*Power 3.1 Data Analysis program to determine the sample size based on a Cohen's f-statistic of 0.25. Power was set at 0.95 and with an alpha of 0.05. Total sample size based on these parameters was 252 patients. Considering that three surgeons, who perform approximately 250 TKAs per year each, will be involved, the investigators estimate that an ability to enroll approximately one-third of all eligible patients seeking TKA and, thus, set a goal for 300 patients to account for patient attrition after study initiation.
Through the use of either conventional, computer navigated or robotic techniques, standard operating procedures will be followed and all surgical procedures will be performed under aseptic conditions. Investigators will implant all commercially available components in compliance with corresponding labeling requirements, and in accordance with appropriate surgical technique(s).
Post-surgical management for study subjects will follow the investigator's standard of care for patients undergoing TKA (e.g., prophylactic antibiotic therapy, prevention of deep vein thrombosis, prevention of pulmonary embolism, etc.). Post-surgical rehabilitative therapy will be as prescribed by the investigator. Post-operative clinical evaluation will be conducted at approximately 6 weeks, 3 months, 6 months and 1 year post-operatively. Subjects will be followed post-operatively for 1 year.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
ROSA
Subjects randomly assigned to this arm will undergo a primary total knee arthroplasty procedure using the ROSA Knee System.
ROSA Knee System
The Zimmer Biomet ROSA Knee System is a commercially available, FDA approved robotic assistant for performing TKA. It uses preoperative x-rays to create a three-dimensional image of the patient's knee anatomy which is used to create a preoperative template of the implants to be used and provides intraoperative guidance for bone cuts during the TKA. The robotic system also assesses the soft tissue envelope around the knee and can assist with the soft tissue balancing of the knee arthroplasty. Alternatively, it can also be used in an imageless mode where bone cuts are performed based on intra-operative mapping using anatomic landmarks.
KneeAlign
Subjects randomly assigned to this arm will undergo a primary total knee arthroplasty procedure using the KneeAlign navigation system.
KneeAlign Computer Assisted Navigation System
The OrthAlign KneeAlign computer assisted navigation system is a commercially available device that uses gyroscopic limb position sensing technology mounted to intramedullary and extramedullary jigs to measure bone resection cuts in TKA that ultimately dictate implant position.
Conventional
Subjects randomly assigned to this arm will undergo a primary total knee arthroplasty procedure using conventional instrumentation.
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
ROSA Knee System
The Zimmer Biomet ROSA Knee System is a commercially available, FDA approved robotic assistant for performing TKA. It uses preoperative x-rays to create a three-dimensional image of the patient's knee anatomy which is used to create a preoperative template of the implants to be used and provides intraoperative guidance for bone cuts during the TKA. The robotic system also assesses the soft tissue envelope around the knee and can assist with the soft tissue balancing of the knee arthroplasty. Alternatively, it can also be used in an imageless mode where bone cuts are performed based on intra-operative mapping using anatomic landmarks.
KneeAlign Computer Assisted Navigation System
The OrthAlign KneeAlign computer assisted navigation system is a commercially available device that uses gyroscopic limb position sensing technology mounted to intramedullary and extramedullary jigs to measure bone resection cuts in TKA that ultimately dictate implant position.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Independent of study participation, patient is a candidate for commercially available Persona or Legion knee components implanted in accordance with product labeling
* Patient has participated in this study-related Informed Consent process
* Patient is willing and able to provide written Informed Consent by signing and dating the Institutional Review Board (IRB) or Ethics Committee (EC) approved Informed Consent form
* Patient is willing and able to complete scheduled study procedures and follow-up evaluations
Exclusion Criteria
* Patient has undergone contralateral unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA) within the last 18 months
* Hip pathology with significant bone loss (e.g., avascular necrosis of the femoral head with collapse, severe dysplasia of the femoral head or the acetabulum)
* Hip pathology severely limiting range of motion (e.g., arthrodesis, severe contracture, chronic severe dislocation)
* Patient is pregnant or considered a member of a protected population (e.g., prisoner, mentally incompetent, etc.)
* Patient has previously received partial or total knee arthroplasty for the ipsilateral knee
* Patients with active knee joint infections (determined clinically at time of pre-op evaluation)
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of California, Los Angeles
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Erik N. Zeegen, MD
Associate Professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
UCLA Santa Monica Medical Center
Santa Monica, California, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IRB#21-002140
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.