FLUOPANC-trial - Fluorescence-guided Surgery of Pancreatic and Bileduct Tumors Using cRGD-ZW800-1
NCT ID: NCT05518071
Last Updated: 2024-06-24
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE2
20 participants
INTERVENTIONAL
2022-11-09
2024-05-23
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Hypofractionated Stereotactic Body Radiation & Fluorouracil or Capecitabine for Locally Advanced Pancreatic Cancer
NCT03073785
Near-infrared Image Guided Surgery in Pancreatic Adenocarcinoma
NCT02743975
Chemotherapy in Treating Patients With Locally Advanced or Metastatic Cancer of the Pancreas or Bile Duct
NCT00010088
68Ga-FAPI-46 in Staging of Pancreatic Adenocarcinoma
NCT06911021
Fluorouracil, Gemcitabine, and Radiation Therapy in Treating Patients With Cancer of the Pancreas
NCT00003216
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Aims of the study:
* To assess the feasibility, safety and tolerability of cRGD-ZW800-1 for the visualization of pancreatic carcinomas, perihilar or distal cholangiocarcinomas and if present associated metastatic lymph nodes and their distant metastases in real-time using specific NIR fluorescence imaging systems.
* Determining the optimal dose and dose interval of a single intravenous bolus injection of cRGD-ZW800-1 for intraoperative NIR imaging
Study design:
Open label, dose-ranging and optimal dose-(interval) selection study, with a two-factorial design. In total 20 patients diagnosed with a malignant tumor of the pancreas, or distal/hilar bile ducts, which are eligible for surgical resection with or without neoadjuvant treatment will be enrolled. These patients will be distributed over four dosing-, and one expansion cohort: Cohort 1 (0.05mg/kg, 2-4h before intervention), Cohort 2 (0.05mg/kg, 14-24h before intervention), Cohort 3 (0.025mg/kg, 2-4h before intervention), Cohort 4 (0.025mg/kg, 14-24h before intervention) and Cohort 5 (expansion cohort). Patients are included if they met the inclusion/exclusion criteria and will be screened during pre-operative work-up for surgery.
Study population: Patients with or without neoadjuvant treatment eligible for surgical resection at the Leiden University Medical Center (LUMC) of histologically proven malignant tumors of the pancreas head, neck and tail. As well as patients with histologically proven tumors of the peri-hilar and distal bile ducts (extrahepatic cholangiocarcinomas) with or without neoadjuvant treatment.
Intervention: Single bolus injection of cRGD-ZW800-1 2-24h before surgery. Intra-operative in-vivo assessment of NIR-fluorescence of tumor, lymph nodes, possible distant metastasis and anatomical related structures. After resection ex-vivo assessment of NIR-fluorescence of all resected tissue, on gross-macroscopy, bread loafs and microscopic slides.
Investigational drug: Intravenous single bolus injection of the targeted NIR fluorophore cRGD-ZW800-1. This targeted 800nm zwitterionic fluorophore developed by the Hospital Pharmacy Department of LUMC consists of the fluorophore ZW800-1 conjugated to the cRGD peptide.
Imaging: Intraoperative imaging will be performed with at least one of the following CE-marked near-infrared (NIR) fluorescence imaging systems: Quest Spectrum imaging platform (v2/3.0) for open-procedures, the Olympus or Karl-Storz system for the diagnostic laparoscopy or the Intuitive Surgical Da Vinci Xi (Firefly-mode) for minimally invasive robot-assisted procedures. With a NIR-imaging system a potential fluorescent signal of the tumor can be evaluated. Furthermore, the Quest Spectrum platform will also be used for evaluation of ex-vivo fluorescence of resected tissue on the back table (Back table imaging) and pathology department (ex-vivo imaging), which shall be performed during and after every procedure.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Cohort 1 - N=4 (0.05mg/kg, 2-4h before intervention)
CRGD-ZW800-1
Intravenous single bolus injection of the targeted NIR fluorophore cRGD-ZW800-1. This targeted 800nm zwitterionic fluorophore developed by the Hospital Pharmacy Department of LUMC consists of the fluorophore ZW800-1 conjugated to the cRGD peptide
Intraoperative near-infrared fluorescence imaging
Intraoperative imaging will be performed with at least one of the following CE-marked near-infrared (NIR) fluorescence imaging systems: Quest Spectrum imaging platform (v2/3.0) for open-procedures, the Olympus or Karl-Storz system for the diagnostic laparoscopy or the Intuitive Surgical Da Vinci Xi (Firefly-mode) for minimally invasive robot-assisted procedures. With a NIR-imaging system a potential fluorescent signal of the tumor can be evaluated. Furthermore, the Quest Spectrum platform will also be used for evaluation of ex-vivo fluorescence of resected tissue on the back table (Back table imaging) and pathology department (ex-vivo imaging), which shall be performed during and after every procedure.
Cohort 2 - N=4 (0.05mg/kg, 14-24h before intervention)
CRGD-ZW800-1
Intravenous single bolus injection of the targeted NIR fluorophore cRGD-ZW800-1. This targeted 800nm zwitterionic fluorophore developed by the Hospital Pharmacy Department of LUMC consists of the fluorophore ZW800-1 conjugated to the cRGD peptide
Intraoperative near-infrared fluorescence imaging
Intraoperative imaging will be performed with at least one of the following CE-marked near-infrared (NIR) fluorescence imaging systems: Quest Spectrum imaging platform (v2/3.0) for open-procedures, the Olympus or Karl-Storz system for the diagnostic laparoscopy or the Intuitive Surgical Da Vinci Xi (Firefly-mode) for minimally invasive robot-assisted procedures. With a NIR-imaging system a potential fluorescent signal of the tumor can be evaluated. Furthermore, the Quest Spectrum platform will also be used for evaluation of ex-vivo fluorescence of resected tissue on the back table (Back table imaging) and pathology department (ex-vivo imaging), which shall be performed during and after every procedure.
Cohort 3 - N=4 (0.025mg/kg, 2-4h before intervention)
CRGD-ZW800-1
Intravenous single bolus injection of the targeted NIR fluorophore cRGD-ZW800-1. This targeted 800nm zwitterionic fluorophore developed by the Hospital Pharmacy Department of LUMC consists of the fluorophore ZW800-1 conjugated to the cRGD peptide
Intraoperative near-infrared fluorescence imaging
Intraoperative imaging will be performed with at least one of the following CE-marked near-infrared (NIR) fluorescence imaging systems: Quest Spectrum imaging platform (v2/3.0) for open-procedures, the Olympus or Karl-Storz system for the diagnostic laparoscopy or the Intuitive Surgical Da Vinci Xi (Firefly-mode) for minimally invasive robot-assisted procedures. With a NIR-imaging system a potential fluorescent signal of the tumor can be evaluated. Furthermore, the Quest Spectrum platform will also be used for evaluation of ex-vivo fluorescence of resected tissue on the back table (Back table imaging) and pathology department (ex-vivo imaging), which shall be performed during and after every procedure.
Cohort 4 - N=4 (0.025mg/kg, 14-24h before intervention)
CRGD-ZW800-1
Intravenous single bolus injection of the targeted NIR fluorophore cRGD-ZW800-1. This targeted 800nm zwitterionic fluorophore developed by the Hospital Pharmacy Department of LUMC consists of the fluorophore ZW800-1 conjugated to the cRGD peptide
Intraoperative near-infrared fluorescence imaging
Intraoperative imaging will be performed with at least one of the following CE-marked near-infrared (NIR) fluorescence imaging systems: Quest Spectrum imaging platform (v2/3.0) for open-procedures, the Olympus or Karl-Storz system for the diagnostic laparoscopy or the Intuitive Surgical Da Vinci Xi (Firefly-mode) for minimally invasive robot-assisted procedures. With a NIR-imaging system a potential fluorescent signal of the tumor can be evaluated. Furthermore, the Quest Spectrum platform will also be used for evaluation of ex-vivo fluorescence of resected tissue on the back table (Back table imaging) and pathology department (ex-vivo imaging), which shall be performed during and after every procedure.
Expansion cohort - N=4 (optimal dose, optimal dose-interval)
CRGD-ZW800-1
Intravenous single bolus injection of the targeted NIR fluorophore cRGD-ZW800-1. This targeted 800nm zwitterionic fluorophore developed by the Hospital Pharmacy Department of LUMC consists of the fluorophore ZW800-1 conjugated to the cRGD peptide
Intraoperative near-infrared fluorescence imaging
Intraoperative imaging will be performed with at least one of the following CE-marked near-infrared (NIR) fluorescence imaging systems: Quest Spectrum imaging platform (v2/3.0) for open-procedures, the Olympus or Karl-Storz system for the diagnostic laparoscopy or the Intuitive Surgical Da Vinci Xi (Firefly-mode) for minimally invasive robot-assisted procedures. With a NIR-imaging system a potential fluorescent signal of the tumor can be evaluated. Furthermore, the Quest Spectrum platform will also be used for evaluation of ex-vivo fluorescence of resected tissue on the back table (Back table imaging) and pathology department (ex-vivo imaging), which shall be performed during and after every procedure.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
CRGD-ZW800-1
Intravenous single bolus injection of the targeted NIR fluorophore cRGD-ZW800-1. This targeted 800nm zwitterionic fluorophore developed by the Hospital Pharmacy Department of LUMC consists of the fluorophore ZW800-1 conjugated to the cRGD peptide
Intraoperative near-infrared fluorescence imaging
Intraoperative imaging will be performed with at least one of the following CE-marked near-infrared (NIR) fluorescence imaging systems: Quest Spectrum imaging platform (v2/3.0) for open-procedures, the Olympus or Karl-Storz system for the diagnostic laparoscopy or the Intuitive Surgical Da Vinci Xi (Firefly-mode) for minimally invasive robot-assisted procedures. With a NIR-imaging system a potential fluorescent signal of the tumor can be evaluated. Furthermore, the Quest Spectrum platform will also be used for evaluation of ex-vivo fluorescence of resected tissue on the back table (Back table imaging) and pathology department (ex-vivo imaging), which shall be performed during and after every procedure.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patients scheduled and eligible for open/robotic resection because of (histologically proven) pancreatic carcinoma with or without neoadjuvant treatment. As well as patients scheduled and eligible for resection because of (histologically proven) distal or perihilar cholangiocarcinoma with or without neoadjuvant treatment.
* All women of childbearing potential and all males must practice effective contraception during the study and be willing and able to continue contraception for at least 30 days after their last dose of study treatment.
* Patients should be capable and willing to give informed consent before study specific procedures;
Exclusion Criteria
* Patients with renal insufficiency (eGFR\<60 ml/min/1,73 m2);
* Patients with a previous kidney transplantation in the medical history;
* Pregnant women, or women giving breast feeding;
* Patients who are immunocompromised and do not have the ability to respond normally to an infection due to an impaired or weakened immune system, caused by either a pre-existing disease or concomitant medications (excluding intended neoadjuvant treatment);
* Presence of any psychological, familial, sociological or geographical condition potentially hampering compliance with the study protocol and follow-up schedule; those conditions should be discussed with the patient before registration in the trial;
* Any condition that the investigator considers to be potentially jeopardizing the patients well-being or the study objectives.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Leiden University Medical Center
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Alexander Vahrmeijer
dr. A.L. Vahrmeijer, MD, PhD
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Leiden University Medical Center
Leiden, , Netherlands
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
de Valk KS, Deken MM, Handgraaf HJM, Bhairosingh SS, Bijlstra OD, van Esdonk MJ, Terwisscha van Scheltinga AGT, Valentijn ARPM, March TL, Vuijk J, Peeters KCMJ, Holman FA, Hilling DE, Mieog JSD, Frangioni JV, Burggraaf J, Vahrmeijer AL. First-in-Human Assessment of cRGD-ZW800-1, a Zwitterionic, Integrin-Targeted, Near-Infrared Fluorescent Peptide in Colon Carcinoma. Clin Cancer Res. 2020 Aug 1;26(15):3990-3998. doi: 10.1158/1078-0432.CCR-19-4156. Epub 2020 Apr 28.
Handgraaf HJM, Boonstra MC, Prevoo HAJM, Kuil J, Bordo MW, Boogerd LSF, Sibinga Mulder BG, Sier CFM, Vinkenburg-van Slooten ML, Valentijn ARPM, Burggraaf J, van de Velde CJH, Frangioni JV, Vahrmeijer AL. Real-time near-infrared fluorescence imaging using cRGD-ZW800-1 for intraoperative visualization of multiple cancer types. Oncotarget. 2017 Mar 28;8(13):21054-21066. doi: 10.18632/oncotarget.15486.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2019-004217-14
Identifier Type: EUDRACT_NUMBER
Identifier Source: secondary_id
NL 71219.058.22
Identifier Type: OTHER
Identifier Source: secondary_id
P21.128
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.