Feasibility of Thin Cp-EBUS Scope BF-UC290F for the Diagnosis of PPLs

NCT ID: NCT05512533

Last Updated: 2025-06-05

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

31 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-09-02

Study Completion Date

2023-07-12

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of the study is to evaluate the diagnostic value and safety of Thin Convex Probe Endobronchial Ultrasound (TCP-EBUS) Scope for peripheral pulmonary lesions (PPLs)

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This study will determine the feasibility of the novel thin convex probe endobronchial ultrasound (TCP-EBUS) Scope for the diagnosis of peripheral pulmonary lesions. The primary end point is to clarify the feasibility of using the thin convex probe EBUS scope to biopsy peripheral pulmonary lesions. The secondary objective is to evaluate operation time, sample adequacy, factors affecting the diagnosis rate, etc. The safety, insertion ability, and operability of the thin convex probe EBUS would also be evaluated.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Peripheral Pulmonary Lesions

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

BF-UC290F for diagnosing PPLs

Thin EBUS endoscope is inserted and used to visualize peripheral pulmonary lesions, and biopsies will be conducted by EBUS-TBNA.

Group Type EXPERIMENTAL

Linear Ultrasound Bronchoscope BF-UC290F (Olympus)

Intervention Type DEVICE

A thin Olympus EBUS bronchoscope BF-UC290F will be used for all endobronchial ultrasound examinations, and biopsies will be conducted with EBUS needles - the ViziShot 2 22G (Olympus).

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Linear Ultrasound Bronchoscope BF-UC290F (Olympus)

A thin Olympus EBUS bronchoscope BF-UC290F will be used for all endobronchial ultrasound examinations, and biopsies will be conducted with EBUS needles - the ViziShot 2 22G (Olympus).

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients older than 18 years old.
* Chest imaging shows the presence of peripheral pulmonary lesions (surrounded by pulmonary parenchyma and located below the segmental bronchus as seen radiographically.) suspicious of malignancy, 0.8-5cm in greatest diameter in need of bronchoscopic biopsy for clinical purposes, and the investigators consider it possible to be biopsied with BF-UC290F (the bronchus adjacent or leading to the PPLs are close to 5mm in diameter, thus BF-UC290F is able to arrival/access).
* Patients without contraindications of bronchoscopy.
* Patients have good medical adherence and signed informed consent.

Exclusion Criteria

* Peripheral pulmonary lesion is pure ground-glass opacity.
* Visible lumen lesions during bronchoscopy
* The lesions were adjacent to the central airway (trachea, left and right main bronchus, and right middle bronchus), and the biopsies by the Thin Convex Probe EBUS Scope BF-UC290F were conducted without leaf bronchus entry
* The investigators believe that patient has other conditions that are not suitable for the study.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Shanghai Chest Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Jiayuan Sun

Director, Department of Endoscopy

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Jiayuan Sun, MD., PhD.

Role: PRINCIPAL_INVESTIGATOR

Shanghai Chest Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Shanghai Chest Hospital

Shanghai, Shanghai Municipality, China

Site Status

Countries

Review the countries where the study has at least one active or historical site.

China

References

Explore related publications, articles, or registry entries linked to this study.

Zhi X, Wang L, Chen J, Zheng X, Li Y, Sun J. Scoring model of convex probe endobronchial ultrasound multimodal imaging in differentiating benign and malignant lung lesions. J Thorac Dis. 2020 Dec;12(12):7645-7655. doi: 10.21037/jtd-2020-abpd-005.

Reference Type BACKGROUND
PMID: 33447457 (View on PubMed)

Fujino K, Ujiie H, Kinoshita T, Lee CY, Igai H, Inage T, Motooka Y, Gregor A, Suzuki M, Yasufuku K. First Evaluation of the Next-Generation Endobronchial Ultrasound System in Preclinical Models. Ann Thorac Surg. 2019 May;107(5):1464-1471. doi: 10.1016/j.athoracsur.2018.11.068. Epub 2019 Jan 2.

Reference Type BACKGROUND
PMID: 30610852 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

SHCHE202208

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Thin EBUS Pilot Study
NCT04745962 COMPLETED