The MOTOR-CD Trial

NCT ID: NCT05363930

Last Updated: 2023-09-14

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

128 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-05-07

Study Completion Date

2022-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Both single-balloon enteroscopy (SBE) and novel motorized spiral enteroscopy (NMSE) are effective techniques for small bowel endoscopy in suspected Crohn's disease (CD). Small bowel endoscopy is indicated for confirming diagnosis when CD is suspected based on clinical features along with cross-sectional small bowel imaging (computed tomography enterography/enteroclysis: CTE or magnetic resonance enterography/enteroclysis: MRE) or capsule endoscopy (CE). It not only helps in diagnosing CD, but it also helps in excluding CD, diagnosing alternate conditions and taking a surgical decision if a tight stricture is found. The pilot study done by the investigators in 177 suspected CD patients (37.2% female, 7-75 years) undergoing total 201 device assisted enteroscopy (DAE) showed that NMSE scores over SBE with regards to small bowel evaluation with complete small bowel coverage and shorter procedure time. The investigators aim to validate this findings by comparing technical performance and diagnostic yield between NMSE (Olympus Medical, Tokyo, Japan) and SBE (Olympus Medical Systems Corporation, Tokyo, Japan) for small bowel evaluation. Additionally the investigators plan to compare depth of insertion, total enteroscopy rates, procedure time, adverse event rates between the two modalities.

To date, no study has compared both modalities in suspected Crohn's disease (CD) requiring small bowel evaluation in a randomized manner. Hence the investigators intend to perform a randomized controlled study based on these preliminary finding with appropriate matching and parallel study design in larger numbers.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Study design

Study population Consecutive patients with suspected Crohn's disease requiring small bowel endoscopy based on abnormal imaging or capsule endoscopy shall be recruited.

Study settings:

The proposed study would be conducted in a high volume tertiary GI centre (Asian Institute of Gastroenterology) performing nearly more than 500 SBE/NMSE procedures per year with an well established inflammatory bowel disease (IBD) registry with more than 7000 IBD patients under follow up.

The study is approved by the institutional review boards and ethics committee. Written informed consent would be taken from each participants and the study would conform to the 1975 Declaration of Helsinki ethical guidelines.

Data collection A survey administration software (google forms) would be used to collect the participant data \[age, sex, comorbidities, clinical features, smoking status, history of intestinal resection, type of DAE, indication of DAE, CT/MRE location and characteristic of lesions, capsule endoscopy findings, depth of insertion, time taken for the procedure, total enteroscopy rates, enteroscopy finding details, cause of failure if any, DAE findings, histopathology details, impact on management, adverse events, hospital stay and any therapeutic procedure performed e.g. endoscopic balloon dilation (EBD) with details\]. Follow-up details for newly diagnosed CD cases would be collected via physical visit or telephonic communication.

Technique and instruments Single balloon enteroscopy: All SBE procedures will be performed with single balloon video-enteroscope (Olympus Medical Systems, Tokyo, Japan) under monitored anaesthesia (deep sedation with propofol). Initially antegrade/retrograde enteroscopy would be performed based on anticipated location in CT failing which enteroscopy would be done from opposite route to reach the lesion. If the desired lesion is not reached via antegrade/retrograde route, hemoclips would be applied or tattooing would be done followed by enteroscopy from opposite direction on the same day under the same anaesthesia using the same overtube. Fluoroscopy would be used in select cases with anticipated therapeutic procedure. All the procedures were done after minimum of 8 hours of fasting and bowel preparation was given with 4 litres of polyethylene glycol (PEG) for all. Duration of procedure would be calculated from the time of introduction of the enteroscope to time of removal. The depth of insertion would be measured using the push and pull technique. If the desired lesion is not reached by a single route and was deemed possible to reach by the other route, the area of maximal insertion shall be marked by India ink tattooing or hemoclip application followed by completion of bidirectional enteroscopy on the same or next working day.

Novel motorized spiral enteroscopy: All the NMSE (Olympus Medical Systems Corporation, Tokyo, Japan) procedures would be performed under general anaesthesia with nasotracheal intubation under fluoroscopic guidance. Four litres of PEG was given to all patients with at least 8 hours of fasting prior to NMSE. Initially antegrade enteroscopy would be performed failing which retrograde enteroscopy would be done to reach the lesion. If the desired lesion is not reached via antegrade route, hemoclips would be applied or tattooing would be done followed by retrograde enteroscopy on the same day under the same anesthesia using the same overtube. The time of procedure will be calculated from insertion of NMSE to its withdrawal. The depth of insertion would be measured by sequential withdrawal technique as described earlier.

All the enteroscopy procedures were performed by four small bowel endoscopists all of whom have performed at least 200 deep enteroscopy. At least 8 biopsies were taken from area of interest during DAE and sent for histopathological analysis. In selected cases, additional samples were sent for detection of tubercular bacilli using mycobacterium tuberculosis (MTB)-polymerase chain reaction (PCR) if clinically tuberculosis was considered as differential diagnosis. Histopathological findings were recorded under the following headings for diagnosing CD: chronic inflammation, architectural distortion and presence of granulomas.

Definitions:

Technical success shall be defined as enteroscope introduction beyond duodenojejunal (DJ) flexure or ileocecal valve via antegrade and retrograde route respectively. The diagnostic yield with DAE shall be defined as the percentage of procedures which confirmed/excluded lesions found on prior cross-sectional imaging (CTE/MRE) or found new/alternate diagnosis explaining the clinical condition. Depth of maximal insertion (DMI) will be defined as the point beyond which DAE advancement was not feasible. Major adverse events are perforation, pancreatitis, bleeding requiring transfusion or procedure related hospitalization. Minor adverse events are superficial mucosal injury, self limiting sore throat/nausea/vomiting, minor bleeding (without need for blood transfusion) or pain abdomen (not requiring hospital admission). Total enteroscopy will be defined as examination of small bowel from DJ flexure to ileocecal valve. Total enteroscopy would be achieved by either uni-directional (antegrade or retrograde route) or bi-directional enteroscopy (using both antegrade and retrograde route). The histopathological diagnosis of CD will be confirmed if non-caseating micro-granulomas are found with either of both of the other two histological features (chronic inflammation and architectural distortion) and alternate diagnosis like small bowel tuberculosis is ruled out based on clinical, radiologic and other relevant findings. Presence of both chronic inflammation and architectural distortion, non-caseating granuloma/chronic inflammation/ architectural distortion alone will be considered suggestive of CD in the appropriate clinical settings.

Sample size

Based on the pilot study by the investigators, diagnostic yield for deep enteroscopy with NMSE and SBE (97.8% and 83.2% respectively, the estimated sample size is total 124 (62 in each group) keeping type 1 error as 0.05 and power as 80%.

Randomisation

Randomisation will be done based on web based randomisation services

Timeline: 2 years Recruitment of 124 suspected CD patients requiring small bowel evaluation over maximum 2 years.

Patient privacy An organised database for the purpose of this study will be formed based on google form with anonymised data set (i.e. name, address, and full post code will be removed, together with any other information which, in conjunction with other data held by or disclosed to the recipient, could identify the patient) which would be entered by clinical research assistant.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Crohn's Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Single balloon enteroscopy

Patients with suspected Crohn's disease requiring small bowel enteroscopy based on clinical features, laboratory investigation and in cross-sectional imaging (computed tomography/magnetic resonance enterography or enteroclysis/ video capsule endoscopy

Group Type ACTIVE_COMPARATOR

Single balloon enteroscopy

Intervention Type DEVICE

Single balloon enteroscopy will be performed with single balloon video-enteroscope (Olympus Medical Systems, Tokyo, Japan) under monitored anaesthesia (deep sedation with propofol). Initially antegrade/retrograde enteroscopy would be performed based on pre-procedure localization failing which enteroscopy would be done from opposite route to reach the lesion. Hemoclips would be applied or tattooing would be done followed by enteroscopy from opposite direction on the same day under the same anaesthesia using the same overtube. Duration of procedure would be calculated from the time of introduction of the enteroscope to time of removal. The depth of insertion would be measured using the push and pull technique.

Novel Motorized Spiral Enteroscopy

Patients with suspected Crohn's disease requiring small bowel enteroscopy based on clinical features, laboratory investigation and in cross-sectional imaging (computed tomography/magnetic resonance enterography or enteroclysis/ video capsule endoscopy

Group Type ACTIVE_COMPARATOR

Novel motorized spiral enteroscopy

Intervention Type DEVICE

Novel motorized spiral enteroscopy (Olympus Medical Systems Corporation, Tokyo, Japan) procedures would be performed under general anaesthesia with nasotracheal intubation under fluoroscopic guidance. Four litres of PEG was given to all patients with at least 8 hours of fasting prior to NMSE. Initially antegrade enteroscopy would be performed failing which retrograde enteroscopy would be done to reach the lesion. If the desired lesion is not reached via antegrade/retrograde route, hemoclips would be applied or tattooing would be done followed by enteroscopy from opposite direction on the same day under the same anesthesia using the same overtube. The time of procedure will be calculated from insertion of NMSE to its withdrawal. The depth of insertion would be measured by sequential withdrawal technique.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Novel motorized spiral enteroscopy

Novel motorized spiral enteroscopy (Olympus Medical Systems Corporation, Tokyo, Japan) procedures would be performed under general anaesthesia with nasotracheal intubation under fluoroscopic guidance. Four litres of PEG was given to all patients with at least 8 hours of fasting prior to NMSE. Initially antegrade enteroscopy would be performed failing which retrograde enteroscopy would be done to reach the lesion. If the desired lesion is not reached via antegrade/retrograde route, hemoclips would be applied or tattooing would be done followed by enteroscopy from opposite direction on the same day under the same anesthesia using the same overtube. The time of procedure will be calculated from insertion of NMSE to its withdrawal. The depth of insertion would be measured by sequential withdrawal technique.

Intervention Type DEVICE

Single balloon enteroscopy

Single balloon enteroscopy will be performed with single balloon video-enteroscope (Olympus Medical Systems, Tokyo, Japan) under monitored anaesthesia (deep sedation with propofol). Initially antegrade/retrograde enteroscopy would be performed based on pre-procedure localization failing which enteroscopy would be done from opposite route to reach the lesion. Hemoclips would be applied or tattooing would be done followed by enteroscopy from opposite direction on the same day under the same anaesthesia using the same overtube. Duration of procedure would be calculated from the time of introduction of the enteroscope to time of removal. The depth of insertion would be measured using the push and pull technique.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Patients with suspected of known IBD requiring small bowel endoscopy
2. Ability to give a signed informed consent.
3. Age ≥18 years -65 years -

Exclusion Criteria

1. Patient not fit for general anaesthesia
2. Pediatric Patients (\<18 years)
3. Pregnant or lactating mother
4. Post operative cases
5. Not willing to participate
Minimum Eligible Age

18 Years

Maximum Eligible Age

65 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Asian Institute of Gastroenterology, India

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Asian Institute of Gastroenterology

Hyderabad, Telangana, India

Site Status

Countries

Review the countries where the study has at least one active or historical site.

India

References

Explore related publications, articles, or registry entries linked to this study.

Pal P, Ramchandani M, Banerjee R, Viswakarma P, Singh AP, Reddy M, Rughwani H, Patel R, Sekaran A, Kanaganti S, Darisetty S, Nabi Z, Singh J, Gupta R, Lakhtakia S, Pradeep R, Venkat Rao G, Tandan M, Reddy DN. Technical performance and diagnostic yield of motorised spiral enteroscopy compared with single-balloon enteroscopy in suspected Crohn's disease: a randomised controlled, open-label study (the MOTOR-CD trial). Gut. 2023 Oct;72(10):1866-1874. doi: 10.1136/gutjnl-2023-329885. Epub 2023 May 17.

Reference Type DERIVED
PMID: 37197904 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

MCD 1; version:1.0

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.