Myoelectric Activity Following Colorectal Surgery and Return of Bowel Function
NCT ID: NCT05298774
Last Updated: 2025-08-03
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
77 participants
INTERVENTIONAL
2022-06-01
2024-09-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
These pilot prospective, open clinical studies suggests that myoelectrical activity, measured on the abdominal surface with a noninvasive wireless patch system, carries predictive value in determining time to feeding and time to flatus following open abdominal surgery. Having such information in advance of clinical measures could facilitate timely interventions, be it early feeding or delaying feeding as dictated by the patient's unique recovery profile. The G-Tech Wireless Patch System would provide a unique insight into the process allowing for a tailored protocol that could improve patient satisfaction and optimize recovery. The system could also enable feedback on the impact to the overall gastrointestinal myoelectrical activity of medications, particularly opioids, used for pain management that are known to inhibit gastrointestinal function by disrupting the normal recovery patterns of colonic motility.23-25 While it remains to be seen, in addition to predicting time to flatus/bowel movement early on, the ability to continue monitoring the patient may allow one to predict onset of secondary complications, such as wound infections or anastomotic leaks, that are associated with ileus. Similarly, given the wireless noninvasive nature of the system the patients could be discharged home with the patches, whereby they would serve as a remote monitoring tool. This could be particularly useful in cases where the patients may have been discharged early and may be at a high risk for readmission. The system would then send updates/alerts to the care team for management and potentially avoid preventable readmissions.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Gastrointestinal Stimulation As a Treatment of Postoperative Ileus Following Extensive Surgery
NCT05752071
Tibial Nerve Stimulation and Postoperative Ileus
NCT02815956
Observe Intestinal Tract Cleaness of Senile Constipation Patients Used Gastrointestinal External Stimulation
NCT06417424
Low Pressure Pneumoperitoneum and Postoperative Ileus
NCT05344417
Acupuncture to Prevent Postoperative Bowel Paralysis (Paralytic Ileus)
NCT00065234
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Clinically, the markers of gastrointestinal recovery are noted by passage of flatus, defecation and the ability to tolerate solid food without significant nausea and vomiting. Passage of stool or flatus - considered a surrogate for intestinal and anastomotic continuity - is often used as the trigger to start stepwise dietary orders with the patient's ability to tolerate each step marking their readiness for the subsequent meal. Fast-track and Enhanced Recovery After Surgery (ERAS) programs that promote early feeding in advance of these clinical markers, along with opioid sparing techniques and use of minimally invasive procedures have been shown to be safe and beneficial for many patients by demonstrating earlier recovery and shorter length of stay. However, it has also been shown that, for as many as 25% of cases, the strategy does not work as noted earlier, with the need for reinsertion of the nasogastric tube and reinstating nil per os status. In a recent study of 513 consecutive colorectal patients who were on an ERAS protocol, 128 patients (24.7%) needed postoperative reinsertion of nasogastric tube at the 3.9±2.9 postoperative day. This suggests that, while early postoperative feeding is beneficial to patients in whom recovery is on track, it does not work in cases where patients are not ready for it.
At present, there is no reliable measurement that can predict gastrointestinal recovery/diet readiness for patients in advance of these clinical markers that may allow for interventions or fast-track programs to facilitate timely recovery. Auscultation for return of bowel sounds, long part of the standard of care, is controversial in its usefulness to indicate recovery. Bowel sounds have shown to have poor correlation with flatus/defecation and have proved unsuccessful in guiding diet interventions.
Smooth muscle electrical activity on the other hand is directly related to gastrointestinal function and motility. Researchers have previously shown a 1:1 correlation between electrical and mechanical (contractile) events in the colon with internally placed electrode-strain gauge force transducers. Electrical activity in the colon has been reported across a wide range of frequencies ranging from 0 to 40 cycles per min (cpm)). Condon et. al have documented the progressive return of colonic electrical related to resolution of postoperative ileus and clinical recovery following surgery. These measurements have been performed using electrodes placed internally during surgery, a major impediment towards broader use of such technology.
G-Tech Medical has developed a noninvasive wireless patch system that measures electrical activity from the gastrointestinal smooth muscles on the abdominal surface. This technology has been studied as part of several non-significant risk IRB approved studies in both adults and pediatric populations to evaluate the patterns of gastrointestinal myoelectrical signals following surgery. The studies demonstrate that signals measured by the G-Tech Wireless patches correlate with clinical markers of postoperative recovery such as time to feeding and time to flatus following pancreaticoduodenectomy and general abdominal surgeries respectively. The study in patients undergoing pancreaticoduodenectomy procedures was conducted in collaboration with researchers at Stanford University. The study demonstrated that measurement of gastric activity beginning immediately after pancreaticoduodenectomy with the G-Tech Wireless Patch System, based on the measured spectral peak near 3 cpm, could distinguish patients with shorter or longer times to diet readiness. The study demonstrated the potential utility of the G-Tech Patch System in providing objective data to identify patients who are progressing as well as, or better than expected, and those who are at risk for delayed gastric emptying. In another open, prospective study, researchers examined the use of the G-Tech Wireless Patch System in predicting time to first flatus by looking at colonic myoelectrical activity following general abdominal surgeries.21 Patients with early flatus had stronger early colonic activity than patients with late flatus. At 36 h post-surgery, a linear fit of time to flatus vs cumulative colonic myoelectrical activity predicted first flatus as much as 5 days (± 22 h) before occurrence.
These pilot prospective, open clinical studies suggests that myoelectrical activity, measured on the abdominal surface with a noninvasive wireless patch system, carries predictive value in determining time to feeding and time to flatus following open abdominal surgery. Having such information in advance of clinical measures could facilitate timely interventions, be it early feeding or delaying feeding as dictated by the patient's unique recovery profile. The G-Tech Wireless Patch System would provide a unique insight into the process allowing for a tailored protocol that could improve patient satisfaction and optimize recovery. The system could also enable feedback on the impact to the overall gastrointestinal myoelectrical activity of medications, particularly opioids, used for pain management that are known to inhibit gastrointestinal function by disrupting the normal recovery patterns of colonic motility. While it remains to be seen, in addition to predicting time to flatus/bowel movement early on, the ability to continue monitoring the patient may allow one to predict onset of secondary complications, such as wound infections or anastomotic leaks, that are associated with ileus. Similarly, given the wireless noninvasive nature of the system the patients could be discharged home with the patches, whereby they would serve as a remote monitoring tool. This could be particularly useful in cases where the patients may have been discharged early and may be at a high risk for readmission. The system would then send updates/alerts to the care team for management and potentially avoid preventable readmissions.
The purpose of the Phase 1 study is to determine if the myoelectrical measurements made by the G-Tech Wireless Patch System correlate with clinical markers of postoperative recovery such as passage of flatus/bowel movement, oral tolerance of diet and discharge readiness. Subsequently the data will be studied to establish which information in the signals is important in determining when to feed patients and possibly discharge them.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Postoperative recovery with G-tech WPS
G-tech WPS
G-tech WPS patches applied and activated within 4 hours of surgery
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
G-tech WPS
G-tech WPS patches applied and activated within 4 hours of surgery
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Eighteen (18) years of age or older
3. Subject is willing and able to follow all study requirements
4. Subject has undergone or will undergo a laparoscopic or open colorectal surgery with resection and anastomosis
Exclusion Criteria
2. Known allergy to medical grade adhesive.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
G-Tech Corporation
INDUSTRY
Yale University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Yale New Haven Hospital
New Haven, Connecticut, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol, Statistical Analysis Plan, and Informed Consent Form
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2000032548
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.