3D OPTIMIZED WMN MPRAGE Increased Detection of Focal Spinal Cord Lesion in Multiple Sclerosis (WHINUME)

NCT ID: NCT05227092

Last Updated: 2025-06-29

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Clinical Phase

NA

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-08-02

Study Completion Date

2026-05-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The aim of this study is to compare the 3D OPTIMIZED MPRAGE WMN sequence to "conventional sequences" used in spinal cord analysis.

The patients will be explored at the cervical level with the conventional 2D sagittal T2 FSE, 2D sagittal STIR, 2D sagittal PSIR, 3D T1 MPRAGE sequences, and the sequence of interest 3D sagittal OPTIMIZED WMN MPRAGE and 3D axial OPTIMIZED WMN MPRAGE. At the thoracic level, with the conventional 2D sagittal T2 FSE, 2D sagittal STIR, 3D T1 MPRAGE sequences and the sequence of interest 3D sagittal OPTIMIZED WMN MPRAGE.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Multiple sclerosis is a common inflammatory disease of the central nervous system and the leading cause of non-traumatic physical disability in young adults.

Spinal cord involvement is common, affecting approximately 90% of patients, and can be revealed by sensory loss, neuropathic pain, spasticity, motor weakness, and bladder and bowel dysfunction. Spinal cord imaging plays an important role in the diagnosis of the disease, but also in the prognosis, particularly with regard to the location and severity of the damage.

Due to the location, small size and mobility of the spinal cord, its imaging raises technical problems and fewer studies have focused on spinal cord involvement in MS than on brain involvement.

Currently, the 2D sagittal T2 FSE sequence is the imaging of choice for spinal cord analysis. Numerous sequences have been developed recently, some of which show an increase in sensitivity at the cervical level, such as short tau inversion recovery (STIR) and phase sensitive inversion recovery (PSIR). The lesion load assessed on these conventional sequences lacks correlation with clinical status, probably due to a multifactorial mechanism of disability in MS, but also probably due to the limitations of the resolution of current sequences.

WHINUME study will investigate at the spinal cord level the interest of an optimised MP-RAGE sequence cancelling the spinal cord white matter signal. The hypothesis is that this sequence could have a good sensitivity, specificity and reproducibility between readers for the detection of spinal cord lesions compared to other sequences at the cervical level but also at the thoracic level. Therefore, it could replace the conventional sequences currently available.

This study will prospectively include 60 patients with multiple sclerosis confirmed by the McDonald 2017 criteria. All patients will sign a consent form. The 3D OPTIMIZED MPRAGE WMN will be compared to conventional sequences.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Multiple Sclerosis

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

3D OPTIMIZED WMN MPRAGE

* At the cervical level the conventional data set: 2D Sagittal T2 FSE/ 2D Sagittal STIR / 2D Sagittal PSIR / 3D MPRAGE and the 3D OPTIMIZED MPRAGE WMN data set with sagittal and axial acquisition.
* At the thoracic level the conventional data set: 2D Sagittal T2 FSE/ 2D Sagittal STIR / 3D MPRAGE and the 3D Sagittal OPTIMIZED MPRAGE WMN data set.

Group Type EXPERIMENTAL

3D OPTIMIZED WMN MPRAGE

Intervention Type DEVICE

* At the cervical level the conventional data set: 2D Sagittal T2 FSE/ 2D Sagittal STIR / 2D Sagittal PSIR / 3D MPRAGE and the 3D OPTIMIZED MPRAGE WMN data set with sagittal and axial acquisition.
* At the thoracic level the conventional data set: 2D Sagittal T2 FSE/ 2D Sagittal STIR / 3D MPRAGE and the 3D Sagittal OPTIMIZED MPRAGE WMN data set.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

3D OPTIMIZED WMN MPRAGE

* At the cervical level the conventional data set: 2D Sagittal T2 FSE/ 2D Sagittal STIR / 2D Sagittal PSIR / 3D MPRAGE and the 3D OPTIMIZED MPRAGE WMN data set with sagittal and axial acquisition.
* At the thoracic level the conventional data set: 2D Sagittal T2 FSE/ 2D Sagittal STIR / 3D MPRAGE and the 3D Sagittal OPTIMIZED MPRAGE WMN data set.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients older than 18 years old
* CIS or RRMS
* Medullary symptomatology less than 6 months
* With or without an objective lesion on a subsequent MRI scan
* Signed the Informed Consent

Exclusion Criteria

* Pregnant or potentially pregnant women
* Breastfeeding woman
* Contraindications to MRI
* Other diagnosis (Neuro-myelitis spectrum disease or Progressive Multiple Sclerosis)
* Surgical history on the spinal cord or lumbar spine
* Patient under legal protection
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University Hospital, Bordeaux

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

CHU de Bordeaux

Bordeaux, , France

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

France

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Vincent Dousset, MD, PhD

Role: CONTACT

+335 56 79 56 04

Amaury Ravache, MD

Role: CONTACT

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Vincent Dousset, Md, PhD

Role: primary

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CHUBX 2021/59

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

MS-ResearchBiomarkerS
NCT05204459 RECRUITING