Feasibility Trial of Magnetic-assisted Colonoscope Platform

NCT ID: NCT05213741

Last Updated: 2023-04-20

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

10 participants

Study Classification

INTERVENTIONAL

Study Start Date

2024-05-31

Study Completion Date

2024-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Colorectal cancer (CRC) screening program can reduce colon cancer-related mortality. Current CRC screening methods include stool occult blood and DNA testing, blood based tests and radiologic tests. Colonoscopy is considered the gold standard to detect colorectal neoplasms. Previous studies have estimated that cancer mortality to be 68% to 88% lower among persons who undergo screening colonoscopy than among those who do not. However, colonoscopy is an invasive examination, and 10% to 20% of patients fail to tolerate the procedure; therefore, greatly reduces the success rate of completion of colon examination.

External controllability of capsule endoscope by means of an applied magnetic field is a possible solution to the maneuvering problem. However, there is no effective system with straight forward clinical applicability till now. This is ascribable to a lack of reliable magnetic instrumentation suitable for such a purpose. We have reported that magnetic field navigator (MFN) can effectively control the locomotion of capsule endoscope. We have demonstrated the feasibility and safety of magnetic-assisted capsule endoscope for the examination of upper gastrointestinal tract. In this study, we develop a magnetic-assisted capsule colonoscope by combination of the integrated circuit complementary metal-oxide-semiconductor imaging sensor, light-emitting diode, and magnetic control technology. This magnetic-assisted capsule colonoscope operation system includes a MFN Platform, high-end hand-controlled joystick, combined circuit component, control interface and software. This magnetic-assisted capsule colonoscope operation system creates a friendly operating environment for the operators, and may establishe a novel screening system for the colon.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

1. Preparation before examination: All subjects must take bowel cleansing drugs as instructed before magnetically controlled colonoscopy After starting to drink laxatives, subjects should continue their daily activities .
2. Magnetically Controlled Colonoscopy procedure:

No anesthesia will be used during the magnetically controlled colonoscopy in this experiment.

The subjects lie down on the magnetic control colonoscopy platform. After the magnetically controlled colonoscopy enters the rectum from the subject's anus, the external magnetron is used to assist and guide the pre-colonoscopy after the magnetically controlled colonoscopy enters the rectum from the subject's anus, and the external magnetron is used to assist and guide the colonoscopy go ahead. During the inspection process, the physician monitors the operation of the magnetically controlled colonoscope throughout the process, and the physician can adjust the movement of the colonoscope when necessary.

Whole colorectal examination is defined as the colonoscope must be inserted into the ileocecal region, and the cecum must be photographed.
3. Pain assessment during examination:

During the colonoscopy, the researchers will conduct a questionnaire to the patients to assess the pain..

The evaluation method is based on the Verbal Scale to evaluate the maximum discomfort, from 0 to 10 points; ; Among them, 0 points are painless, 10 points are the most severe.

If the patient's pain assessment score is greater than 5 and the patient cannot tolerate colonoscopy, the examination will be terminated.

If there are difficulties during the examination, and the magnetic-controlled colonoscopy cannot complete the examination within 1 hours, the examination shall be terminated.
4. After the colonoscopy is completed, the researcher conducts an overall pain assessment to the subjects by means of a questionnaire. On the day after the colonoscopy, the researcher asked the subjects whether they would like to accept the next colonoscopy follow-up examination by means of a questionnaire.
5. After the magnetic-controlled colonoscopy, the images and time recorded by the colonoscopy will be interpreted by computer-captured images, and the completion rate of the magnetic-controlled colonoscopy will be analyzed.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Colonoscopy Colorectal Cancer

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

DEVICE_FEASIBILITY

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Magnetic-assisted colonoscopy group

Participants in this group will recieve magnetic-assisted colonoscopic examination

Group Type EXPERIMENTAL

Autonomous navigation of a magnetic colonoscope

Intervention Type DEVICE

The proposed magnetic-assisted colonoscope system consists of an megnetic field nevigator, magnetic-assisted colonoscope, and image receiving decoder. All participants will receive the magnetic-assisted colonoscopic examination by using this proposed magnetic-assisted colonoscope system

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Autonomous navigation of a magnetic colonoscope

The proposed magnetic-assisted colonoscope system consists of an megnetic field nevigator, magnetic-assisted colonoscope, and image receiving decoder. All participants will receive the magnetic-assisted colonoscopic examination by using this proposed magnetic-assisted colonoscope system

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

Aged 20-65 health volunteers without any contraindication

Exclusion Criteria

1. Person allergy to polyethylene glycol.
2. Phenylkentouria
3. Congestive heart failure (NYHA grade 3)
4. Renal function impairment.
5. Difficulty in swallowing, GI perforation, GI bleeding, toxic enterocolitis, toxic colitis, megacolon, diverticulitis, peritonitis
6. Body weight less than 20kg
7. Wrist more than 120cm
8. Gastrointestinal tract obstruction
9. Pregnant woman.
10. Person with electrical medical implantation such as pacemaker, cochlear implant or other medical devices.
11. Person implanted with metal medical device such as metal implantation, metallic stent, metallic denture, metallic valve, metallic joint, metallic joint or plate.
12. Person with history of abdominal surgery.
13. Person with cancer.
14. Person with bleeding tendency
15. Person with asthma
16. History of cardiac infraction, pulmonary embolism, stroke in recent 6 months
17. Heart failure with NYHA grades 4
Minimum Eligible Age

20 Years

Maximum Eligible Age

65 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Ministry of Health and Welfare, Taiwan

OTHER_GOV

Sponsor Role collaborator

Taipei Medical University WanFang Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Fat-Moon Suk

Attending physician

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

FAT-MOON SUK, M.D.

Role: PRINCIPAL_INVESTIGATOR

Taipei Medical University Wan Fang Hospital

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

FAT-MOON SUK, M.D.

Role: CONTACT

+886229307930 ext. 1541

References

Explore related publications, articles, or registry entries linked to this study.

Lien GS, Liu CW, Jiang JA, Chuang CL, Teng MT. Magnetic control system targeted for capsule endoscopic operations in the stomach--design, fabrication, and in vitro and ex vivo evaluations. IEEE Trans Biomed Eng. 2012 Jul;59(7):2068-79. doi: 10.1109/TBME.2012.2198061. Epub 2012 May 7.

Reference Type BACKGROUND
PMID: 22581127 (View on PubMed)

Yang CS, Suk FM, Chen CN, Chuang CL, Jiang JA, Liu CW, Lien GS. Colonoscopy with magnetic control system to navigate the forepart of colonoscope shortens the cecal intubation time. Surg Endosc. 2014 Aug;28(8):2480-3. doi: 10.1007/s00464-014-3460-7. Epub 2014 Mar 20.

Reference Type BACKGROUND
PMID: 24648105 (View on PubMed)

Huang HE, Yen SY, Chu CF, Suk FM, Lien GS, Liu CW. Autonomous navigation of a magnetic colonoscope using force sensing and a heuristic search algorithm. Sci Rep. 2021 Aug 13;11(1):16491. doi: 10.1038/s41598-021-95760-7.

Reference Type BACKGROUND
PMID: 34389760 (View on PubMed)

Lien GS, Wu MS, Chen CN, Liu CW, Suk FM. Feasibility and safety of a novel magnetic-assisted capsule endoscope system in a preliminary examination for upper gastrointestinal tract. Surg Endosc. 2018 Apr;32(4):1937-1944. doi: 10.1007/s00464-017-5887-0. Epub 2017 Oct 25.

Reference Type BACKGROUND
PMID: 29071416 (View on PubMed)

Yen SY, Huang HE, Lien GS, Liu CW, Chu CF, Huang WM, Suk FM. Automatic lumen detection and magnetic alignment control for magnetic-assisted capsule colonoscope system optimization. Sci Rep. 2021 Mar 19;11(1):6460. doi: 10.1038/s41598-021-86101-9.

Reference Type BACKGROUND
PMID: 33742067 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

N202004113

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

National Colorectal Polyp Care
NCT03712059 COMPLETED