Feasibility Trial of Magnetic-assisted Colonoscope Platform
NCT ID: NCT05213741
Last Updated: 2023-04-20
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
10 participants
INTERVENTIONAL
2024-05-31
2024-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
External controllability of capsule endoscope by means of an applied magnetic field is a possible solution to the maneuvering problem. However, there is no effective system with straight forward clinical applicability till now. This is ascribable to a lack of reliable magnetic instrumentation suitable for such a purpose. We have reported that magnetic field navigator (MFN) can effectively control the locomotion of capsule endoscope. We have demonstrated the feasibility and safety of magnetic-assisted capsule endoscope for the examination of upper gastrointestinal tract. In this study, we develop a magnetic-assisted capsule colonoscope by combination of the integrated circuit complementary metal-oxide-semiconductor imaging sensor, light-emitting diode, and magnetic control technology. This magnetic-assisted capsule colonoscope operation system includes a MFN Platform, high-end hand-controlled joystick, combined circuit component, control interface and software. This magnetic-assisted capsule colonoscope operation system creates a friendly operating environment for the operators, and may establishe a novel screening system for the colon.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Multiple Screening Methods for the Detection of Chinese Colorectal Advanced Adenomatous Polyps and Cancer
NCT03411707
Clinical Application of an Automated Liquid Biopsy Platform for Early Detection of Colorectal Cancer
NCT03476122
Evaluation of a Point-of-care Testing Instrument for Fecal Immunochemical Test
NCT05232721
A Comparison of Different Fecal Occult Blood Test for Colorectal Cancer Screening
NCT04454099
Quality of Life of Colorectal Cancer Screenees in the Period Between Colonoscopy and Next Clinic Visit for Final Report: Does Real-time Endoscopic Optical Diagnosis Improve Their Quality of Life
NCT04684355
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
2. Magnetically Controlled Colonoscopy procedure:
No anesthesia will be used during the magnetically controlled colonoscopy in this experiment.
The subjects lie down on the magnetic control colonoscopy platform. After the magnetically controlled colonoscopy enters the rectum from the subject's anus, the external magnetron is used to assist and guide the pre-colonoscopy after the magnetically controlled colonoscopy enters the rectum from the subject's anus, and the external magnetron is used to assist and guide the colonoscopy go ahead. During the inspection process, the physician monitors the operation of the magnetically controlled colonoscope throughout the process, and the physician can adjust the movement of the colonoscope when necessary.
Whole colorectal examination is defined as the colonoscope must be inserted into the ileocecal region, and the cecum must be photographed.
3. Pain assessment during examination:
During the colonoscopy, the researchers will conduct a questionnaire to the patients to assess the pain..
The evaluation method is based on the Verbal Scale to evaluate the maximum discomfort, from 0 to 10 points; ; Among them, 0 points are painless, 10 points are the most severe.
If the patient's pain assessment score is greater than 5 and the patient cannot tolerate colonoscopy, the examination will be terminated.
If there are difficulties during the examination, and the magnetic-controlled colonoscopy cannot complete the examination within 1 hours, the examination shall be terminated.
4. After the colonoscopy is completed, the researcher conducts an overall pain assessment to the subjects by means of a questionnaire. On the day after the colonoscopy, the researcher asked the subjects whether they would like to accept the next colonoscopy follow-up examination by means of a questionnaire.
5. After the magnetic-controlled colonoscopy, the images and time recorded by the colonoscopy will be interpreted by computer-captured images, and the completion rate of the magnetic-controlled colonoscopy will be analyzed.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DEVICE_FEASIBILITY
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Magnetic-assisted colonoscopy group
Participants in this group will recieve magnetic-assisted colonoscopic examination
Autonomous navigation of a magnetic colonoscope
The proposed magnetic-assisted colonoscope system consists of an megnetic field nevigator, magnetic-assisted colonoscope, and image receiving decoder. All participants will receive the magnetic-assisted colonoscopic examination by using this proposed magnetic-assisted colonoscope system
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Autonomous navigation of a magnetic colonoscope
The proposed magnetic-assisted colonoscope system consists of an megnetic field nevigator, magnetic-assisted colonoscope, and image receiving decoder. All participants will receive the magnetic-assisted colonoscopic examination by using this proposed magnetic-assisted colonoscope system
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
2. Phenylkentouria
3. Congestive heart failure (NYHA grade 3)
4. Renal function impairment.
5. Difficulty in swallowing, GI perforation, GI bleeding, toxic enterocolitis, toxic colitis, megacolon, diverticulitis, peritonitis
6. Body weight less than 20kg
7. Wrist more than 120cm
8. Gastrointestinal tract obstruction
9. Pregnant woman.
10. Person with electrical medical implantation such as pacemaker, cochlear implant or other medical devices.
11. Person implanted with metal medical device such as metal implantation, metallic stent, metallic denture, metallic valve, metallic joint, metallic joint or plate.
12. Person with history of abdominal surgery.
13. Person with cancer.
14. Person with bleeding tendency
15. Person with asthma
16. History of cardiac infraction, pulmonary embolism, stroke in recent 6 months
17. Heart failure with NYHA grades 4
20 Years
65 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Ministry of Health and Welfare, Taiwan
OTHER_GOV
Taipei Medical University WanFang Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Fat-Moon Suk
Attending physician
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
FAT-MOON SUK, M.D.
Role: PRINCIPAL_INVESTIGATOR
Taipei Medical University Wan Fang Hospital
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
References
Explore related publications, articles, or registry entries linked to this study.
Lien GS, Liu CW, Jiang JA, Chuang CL, Teng MT. Magnetic control system targeted for capsule endoscopic operations in the stomach--design, fabrication, and in vitro and ex vivo evaluations. IEEE Trans Biomed Eng. 2012 Jul;59(7):2068-79. doi: 10.1109/TBME.2012.2198061. Epub 2012 May 7.
Yang CS, Suk FM, Chen CN, Chuang CL, Jiang JA, Liu CW, Lien GS. Colonoscopy with magnetic control system to navigate the forepart of colonoscope shortens the cecal intubation time. Surg Endosc. 2014 Aug;28(8):2480-3. doi: 10.1007/s00464-014-3460-7. Epub 2014 Mar 20.
Huang HE, Yen SY, Chu CF, Suk FM, Lien GS, Liu CW. Autonomous navigation of a magnetic colonoscope using force sensing and a heuristic search algorithm. Sci Rep. 2021 Aug 13;11(1):16491. doi: 10.1038/s41598-021-95760-7.
Lien GS, Wu MS, Chen CN, Liu CW, Suk FM. Feasibility and safety of a novel magnetic-assisted capsule endoscope system in a preliminary examination for upper gastrointestinal tract. Surg Endosc. 2018 Apr;32(4):1937-1944. doi: 10.1007/s00464-017-5887-0. Epub 2017 Oct 25.
Yen SY, Huang HE, Lien GS, Liu CW, Chu CF, Huang WM, Suk FM. Automatic lumen detection and magnetic alignment control for magnetic-assisted capsule colonoscope system optimization. Sci Rep. 2021 Mar 19;11(1):6460. doi: 10.1038/s41598-021-86101-9.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
N202004113
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.