Real Time ST-segment Deviation Detection in High-risk Patients Detected by Wireless Single-lead ECG
NCT ID: NCT05171595
Last Updated: 2022-01-12
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
698 participants
OBSERVATIONAL
2018-02-20
2020-06-09
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Routine Mini-invasive Electrophysiology Study for Patients Feeling Tachycardia, With a Negative Holter ECG
NCT00251121
Smartphone Twelve Lead Electrocardiogram Utility In ST-Elevation Myocardial Infarction
NCT02498405
Ultra-high-frequency ECG for Prediction of Left Ventricular Remodeling
NCT04908033
Evaluation of Electrocardiographic Measurements by High Density Electrode ECG
NCT04921501
Using Heart Electrical Signals to Study How Well Treatments Prevent Dangerous Heart Rhythms in Active People
NCT07014579
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Assesment of wireless ECG-monitoring devices is essential for patient monitoring as it enables activity and out-of-hospital monitoring. Former studies have found a random variation for ST-deviations between wireless single-lead ECG and 12-lead ECG, which suggests that clinical monitoring of ST-deviations by single-lead ECG must be corrected for this to minimize false positive cases. Thus, we aimed to assess how a corrected limit of agreement for ST-deviations affects the ability to detect true myocardial ischemia by comparing thresholds to troponin elevations.
Methods:
This study sought to analyze data from two WARD cohort studies (NCT03491137) and (NCT03660501). Patients were included at Rigshospitalet and Bispebjerg Hospital from February 2018 to September 2020. The Surgery and COPD studies consisted of 505 and 202 patients, respectively, who were hospitalized with AECOPD or scheduled for elective major abdominal surgery lasting \> 2 hours. All patients were monitored with wireless equipment, which continuously measured vital signs. The continuous wireless monitoring used in this study consisted of a single-lead ECG patch (Isansys Life Touch patch) which consists of two ECG electrodes placed on the left side of the patients' thorax. The patch measures respiratory rate (RR), heart rate (HR), heart rate variability (HRV) and electrocardiogram (ECG)s. Another monitoring device was the plasma concentration of high-sensitive cardiac troponin T (hsTnT, Cobas 8000, e801 module, Diagnostics Roche). In this study, patients were divided into a myocardial injury group with TnT elevations (of 20-64 ng/L with an absolute change of ≥ 5 ng/L, or a hsTnT level ≥65 ng/L, both evaluated as due to ischemic etiology) and a group with no myocardial injury.
Analysis:
Baseline characteristics of patients undergoing major abdominal surgery and patients admitted with AECOPD with and without myocardial injury will be summarized in frequency tables including Using descriptive statistics, we will describe the occurrence of ST-segment deviations in the single-lead (Lifetouch) ECG in patients with and without myocardial injury as well as the association between ST-deviation and subsequent myocardial injury, which will be adjusted for known risk factors; age, gender, BMI, daily smoker (never-, previous-, current smoker), alcohol consumption (none, below- or above recommendations), ASA classification (ASA 1,2,3,4), history of myocardial infarction, history of diabetes mellitus, history of chronic heart failure. Furthermore, the sensitivity and specificity of continuous wireless single-lead ECG with the applied threshold of \<-0.255 mV and \> 0.245 mV will be determined. Receiver operating characteristics (ROC) analyses will be made to determine which type of ST-deviation and which specific threshold value was most sensitive for TnT elevations. Through ROC analyses it will also be examined how different variations of durations affect the thresholds' sensitivity and specificity. Statistical analysis will be performed using statistical software SPSS.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
no myocardial injury
In this study, patients were divided into groups of myocardial injury, where patients had TnT elevations (of 20-64 ng/L with an absolute change of ≥ 5 ng/L, or a hsTnT level ≥65 ng/L, both evaluated as due to ischemic etiology) and a group with no myocardial injury.
Lifetouch single-lead ECG monitoring
The continuous wireless monitoring is a single-lead ECG patch (Isansys Life Touch patch) which consists of two ECG electrodes placed on the left side of the patients' thorax. The patch measures respiratory rate (RR), heart rate (HR), heart rate variability (HRV) and electrocardiogram (ECG)s.
high-sensitive TnT measurements
Another monitoring device in the study was the plasma concentration of high-sensitive cardiac troponin T (hsTnT).
Myocardial injury
In this study, patients were divided into groups of myocardial injury, where patients had TnT elevations (of 20-64 ng/L with an absolute change of ≥ 5 ng/L, or a hsTnT level ≥65 ng/L, both evaluated as due to ischemic etiology) and a group with no myocardial injury.
Lifetouch single-lead ECG monitoring
The continuous wireless monitoring is a single-lead ECG patch (Isansys Life Touch patch) which consists of two ECG electrodes placed on the left side of the patients' thorax. The patch measures respiratory rate (RR), heart rate (HR), heart rate variability (HRV) and electrocardiogram (ECG)s.
high-sensitive TnT measurements
Another monitoring device in the study was the plasma concentration of high-sensitive cardiac troponin T (hsTnT).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Lifetouch single-lead ECG monitoring
The continuous wireless monitoring is a single-lead ECG patch (Isansys Life Touch patch) which consists of two ECG electrodes placed on the left side of the patients' thorax. The patch measures respiratory rate (RR), heart rate (HR), heart rate variability (HRV) and electrocardiogram (ECG)s.
high-sensitive TnT measurements
Another monitoring device in the study was the plasma concentration of high-sensitive cardiac troponin T (hsTnT).
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* ≥ 18 years
* Patients admitted to emergency departments or pulmonary wards with AECOPD as admission diagnosis with suspected acute exacerbation of COPD
* The diagnosis had to be sustained in the patient record at the time of inclusion
* Expected admittance longer than 24 hours
* Possibility of an investigator to include the patient within 24 hours from admission
WARD-Surgery:
* ≥ 60 years
* Elective major abdominal cancer surgery
* Estimated surgical duration ≥ 2 hours.
Exclusion Criteria
* Patients who were not expected to cooperate to wear the monitoring equipment
* Unable to give informed consent
* Patients who were withheld active treatment
* Implanted cardioverter defibrillator or pacemaker
* Severe allergy for plaster/silicone
WARD-Surgery:
* Implanted cardioverter defibrillator or pacemaker
* Allergy to study devices
* Severe cognitive impairment assessed by MMSE
* Inability to cooperate wearing the wireless monitoring equipment
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Rigshospitalet, Denmark
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Jonathan Attilla Koefoed Starling
Medical Student
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Rigshospitalet, Department of Anesthesiology, Centre for Cancer and Organ Diseases, University of Copenhagen, Blegdamsvej 9, 2200 Copenhagen, Denmark
Copenhagen, , Denmark
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ST-Deviation WARD
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.