Real Time ST-segment Deviation Detection in High-risk Patients Detected by Wireless Single-lead ECG

NCT ID: NCT05171595

Last Updated: 2022-01-12

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

698 participants

Study Classification

OBSERVATIONAL

Study Start Date

2018-02-20

Study Completion Date

2020-06-09

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study primarily aims to describe the frequency of significant ST-deviations, defined as ECG-ST-deviations \<-0.255 or \>0.245 mV for a minimum duration of 30 minutes as measured by a single-lead ECG in patients admitted with AECOPD or following major abdominal surgery. Secondarily we will describe the frequency of ST-deviations \<-0.255 or \>0.245 mV for a minimum duration of 1, 10 and 20 minutes, respectively, as well as for patients with ST-deviations \<-0.1 or \>0.1 mV for a minimum duration of 1, 10, 20 and 30 minutes, respectively. Lastly, we will investigate the association between ST-deviations and subsequent myocardial injury while adjusting for known risk factors.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Background:

Assesment of wireless ECG-monitoring devices is essential for patient monitoring as it enables activity and out-of-hospital monitoring. Former studies have found a random variation for ST-deviations between wireless single-lead ECG and 12-lead ECG, which suggests that clinical monitoring of ST-deviations by single-lead ECG must be corrected for this to minimize false positive cases. Thus, we aimed to assess how a corrected limit of agreement for ST-deviations affects the ability to detect true myocardial ischemia by comparing thresholds to troponin elevations.

Methods:

This study sought to analyze data from two WARD cohort studies (NCT03491137) and (NCT03660501). Patients were included at Rigshospitalet and Bispebjerg Hospital from February 2018 to September 2020. The Surgery and COPD studies consisted of 505 and 202 patients, respectively, who were hospitalized with AECOPD or scheduled for elective major abdominal surgery lasting \> 2 hours. All patients were monitored with wireless equipment, which continuously measured vital signs. The continuous wireless monitoring used in this study consisted of a single-lead ECG patch (Isansys Life Touch patch) which consists of two ECG electrodes placed on the left side of the patients' thorax. The patch measures respiratory rate (RR), heart rate (HR), heart rate variability (HRV) and electrocardiogram (ECG)s. Another monitoring device was the plasma concentration of high-sensitive cardiac troponin T (hsTnT, Cobas 8000, e801 module, Diagnostics Roche). In this study, patients were divided into a myocardial injury group with TnT elevations (of 20-64 ng/L with an absolute change of ≥ 5 ng/L, or a hsTnT level ≥65 ng/L, both evaluated as due to ischemic etiology) and a group with no myocardial injury.

Analysis:

Baseline characteristics of patients undergoing major abdominal surgery and patients admitted with AECOPD with and without myocardial injury will be summarized in frequency tables including Using descriptive statistics, we will describe the occurrence of ST-segment deviations in the single-lead (Lifetouch) ECG in patients with and without myocardial injury as well as the association between ST-deviation and subsequent myocardial injury, which will be adjusted for known risk factors; age, gender, BMI, daily smoker (never-, previous-, current smoker), alcohol consumption (none, below- or above recommendations), ASA classification (ASA 1,2,3,4), history of myocardial infarction, history of diabetes mellitus, history of chronic heart failure. Furthermore, the sensitivity and specificity of continuous wireless single-lead ECG with the applied threshold of \<-0.255 mV and \> 0.245 mV will be determined. Receiver operating characteristics (ROC) analyses will be made to determine which type of ST-deviation and which specific threshold value was most sensitive for TnT elevations. Through ROC analyses it will also be examined how different variations of durations affect the thresholds' sensitivity and specificity. Statistical analysis will be performed using statistical software SPSS.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Myocardial Injury

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

no myocardial injury

In this study, patients were divided into groups of myocardial injury, where patients had TnT elevations (of 20-64 ng/L with an absolute change of ≥ 5 ng/L, or a hsTnT level ≥65 ng/L, both evaluated as due to ischemic etiology) and a group with no myocardial injury.

Lifetouch single-lead ECG monitoring

Intervention Type DEVICE

The continuous wireless monitoring is a single-lead ECG patch (Isansys Life Touch patch) which consists of two ECG electrodes placed on the left side of the patients' thorax. The patch measures respiratory rate (RR), heart rate (HR), heart rate variability (HRV) and electrocardiogram (ECG)s.

high-sensitive TnT measurements

Intervention Type DIAGNOSTIC_TEST

Another monitoring device in the study was the plasma concentration of high-sensitive cardiac troponin T (hsTnT).

Myocardial injury

In this study, patients were divided into groups of myocardial injury, where patients had TnT elevations (of 20-64 ng/L with an absolute change of ≥ 5 ng/L, or a hsTnT level ≥65 ng/L, both evaluated as due to ischemic etiology) and a group with no myocardial injury.

Lifetouch single-lead ECG monitoring

Intervention Type DEVICE

The continuous wireless monitoring is a single-lead ECG patch (Isansys Life Touch patch) which consists of two ECG electrodes placed on the left side of the patients' thorax. The patch measures respiratory rate (RR), heart rate (HR), heart rate variability (HRV) and electrocardiogram (ECG)s.

high-sensitive TnT measurements

Intervention Type DIAGNOSTIC_TEST

Another monitoring device in the study was the plasma concentration of high-sensitive cardiac troponin T (hsTnT).

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Lifetouch single-lead ECG monitoring

The continuous wireless monitoring is a single-lead ECG patch (Isansys Life Touch patch) which consists of two ECG electrodes placed on the left side of the patients' thorax. The patch measures respiratory rate (RR), heart rate (HR), heart rate variability (HRV) and electrocardiogram (ECG)s.

Intervention Type DEVICE

high-sensitive TnT measurements

Another monitoring device in the study was the plasma concentration of high-sensitive cardiac troponin T (hsTnT).

Intervention Type DIAGNOSTIC_TEST

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

WARD-COPD:

* ≥ 18 years
* Patients admitted to emergency departments or pulmonary wards with AECOPD as admission diagnosis with suspected acute exacerbation of COPD
* The diagnosis had to be sustained in the patient record at the time of inclusion
* Expected admittance longer than 24 hours
* Possibility of an investigator to include the patient within 24 hours from admission

WARD-Surgery:

* ≥ 60 years
* Elective major abdominal cancer surgery
* Estimated surgical duration ≥ 2 hours.

Exclusion Criteria

WARD-COPD:

* Patients who were not expected to cooperate to wear the monitoring equipment
* Unable to give informed consent
* Patients who were withheld active treatment
* Implanted cardioverter defibrillator or pacemaker
* Severe allergy for plaster/silicone

WARD-Surgery:

* Implanted cardioverter defibrillator or pacemaker
* Allergy to study devices
* Severe cognitive impairment assessed by MMSE
* Inability to cooperate wearing the wireless monitoring equipment
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Rigshospitalet, Denmark

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Jonathan Attilla Koefoed Starling

Medical Student

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Rigshospitalet, Department of Anesthesiology, Centre for Cancer and Organ Diseases, University of Copenhagen, Blegdamsvej 9, 2200 Copenhagen, Denmark

Copenhagen, , Denmark

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Denmark

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

ST-Deviation WARD

Identifier Type: -

Identifier Source: org_study_id