Precision of the Icare200 for Measuring Intraocular Pressure
NCT ID: NCT05147610
Last Updated: 2022-07-25
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
171 participants
INTERVENTIONAL
2021-12-01
2022-07-21
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
There are also many other devices that can be used to measure IOP, including those using rebound tonometry like the Icare 200.
The rebound tonometer would systematize IOP screening because of its ease of use, provided its measurements are reliable. In this prospective study, investigators will be measuring participant's IOP with Goldmann Applanation Tonometry, Icare 200 Tonometer and Air Puff Tonometry to see if there is an agreement in IOP between the different devices. Investigators will also look if there is a concordance between central corneal thickness and IOP. Moreover, investigators will look if there is a IOP concordance between the 3 different devices for hight BMI people. Indeed, higher body mass index tend to have difficulties with proper positioning at the slit lamp that may lead to inaccurate GAT measurements. Additionally, stress level of the patients with different tonometry devices will be recorded using a visual analog scale.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
ICare Self-tonometry - A Head-to-head Comparison to the Gold Standard Goldmann Tonometer
NCT01733550
iCare® Home vs Goldmann Applanation Tonometry
NCT04911387
Assessment of Home Tonometry in Glaucoma
NCT03057301
Intraocular Pressure Data Collection With Tonometers
NCT06450587
Goldmann Applanation Tonometry, Dynamic Contour Tonometry, and Corvis ST Tonometer
NCT02624427
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Rebound tonometers determine intraocular pressure by bouncing a small plastic tipped metal probe against the cornea.
As IOP increases, impact time decreases and rebound increases. It is portable, does not require the use of eye drops and is particularly suitable for children and non-cooperative patients. The examination is painless and can be performed without contact anesthesia. Different versions of tonometer using this principle exist. With the Icare 200 six measurements are taken. The 2 extreme values are eliminated and the average of the 4 remaining values gives the IOP.
In healthy subjects, the Icare tonometer gives results comparable to those of the Goldmann tonometer (1) with differences of less than 3 mmHg in 80% of cases (2).
In the literature, the type of rebound tonometer differs from that used in our study. Most of the previous studies compare the Icare RT01i, the Icare PRO, the Icare ONE, the Icare HOME or even the Icare 100 which are much older versions.
The Icare 200, the most recent model dating from 2018, has benefited from technical improvements. Intraocular pressure can be taken in any position.
Only one article in the literature has studied the diagnostic performance of Icare200 to date. In this study, Icare200 was compared with the Perkins tonometer in 2 groups of people, one group of healthy subjects and one group of patients with congenital glaucoma.
To date, we have no studies investigating the diagnostic performance of the iCare200 compared to the Goldmann tonometer. It is the interest of this study to compare the relationship of the IOP measurements obtained by Icare 200, Air Puff Tonometer and Goldmann Applanation Tonometry.
For this we have chosen to carry out a prospective study. We have chosen to include consenting adult patients consulting in ophthalmology consultation at Clermont-Ferrand University Hospital. This results in a large panel of patients with different IOP in order to observe enough IOP variability.
IOP measurements appear to correlate with corneal pachymetry (3). So, we chose to organize 4 subgroups according to pachymetry estimated by TONOREF III (high pachymetry, i.e. corneal thickness greater than 560um; low pachymetry, i.e. corneal thickness less than 500um; normal pachymetry, i.e. corneal thickness between 500 and 560um and subnormal pachymetry, i.e. corneal thickness between 500 and 520um).
Patient anxiety during tonometry will be measured using a visual analogue scale.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
patients requiring an IOP (intra-Ocular Pression) measurement
group representing adults patients in ophthalmologic consultation requiring an IOP measurement
Intraocular pression
First, measurement of the eye pressure by air-puff tonometry and estimation of the pachymetries with the TONOREF III.
Secondly, measurement of the eye pressure by GAT. Thirdly, measurement of the eye pressure by Icare 200.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Intraocular pression
First, measurement of the eye pressure by air-puff tonometry and estimation of the pachymetries with the TONOREF III.
Secondly, measurement of the eye pressure by GAT. Thirdly, measurement of the eye pressure by Icare 200.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Able to give informed consent
* Being affiliated with a social security system
Exclusion Criteria
* Participants who are unable to have IOP measured by air puff Tonometry
* Age younger than 18 years
* Inability to sit
* Corneal ulcer
* Refractive surgery
* Corneal Astigmatism \>3D
* Participants who wear contact lenses
* Pregnancy
* Unable to give consent
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University Hospital, Clermont-Ferrand
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Adrien Coutu
Role: PRINCIPAL_INVESTIGATOR
University Hospital, Clermont-Ferrand
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
CHU de Clermont-Ferrand
Clermont-Ferrand, , France
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2021-A00556-35
Identifier Type: OTHER
Identifier Source: secondary_id
RBHP 2021 COUTU
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.