Dexcom Hybrid Closed Loop Insulin Pump Study in Type 1 Diabetes
NCT ID: NCT05059860
Last Updated: 2025-09-18
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
30 participants
OBSERVATIONAL
2023-06-09
2025-05-23
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The Tandem t:slim X2™ insulin pump has recently become available in NHS Scotland and can link with the Dexcom G6 continuous glucose monitoring (CGM) system.
The Tandem Control IQ hybrid closed loop system is made up of the Tandem insulin pump communicating wirelessly with the Dexcom G6 CGM. The algorithm within the pump then automatically controls the background (basal) insulin infusion rate. Manually delivered bolus insulin is still required for meals. This system is designed to finely tune insulin delivery and increase the amount of time that glucose is in the target range, reducing hypoglycaemia and hyperglycaemia.
Insulin pumps are funded by NHS Scotland, but the Dexcom G6 continuous glucose monitoring system is not, so this hybrid closed loop system is not currently routinely available in NHS Scotland.
The purpose of this study is to gain experience of this system and investigate how effective and acceptable the hybrid closed loop system is for people in Scotland. Participants will be provided with the Dexcom G6 CGM device to link to their current pump to create the hybrid closed loop system for the duration of the study.
30 people with Type 1 diabetes who have been using the Tandem pump for at least one month will be invited to participate.
The study will include a screening visit, a 30 day run-in period, 52 week treatment period and 12 week follow-up period. Diabetes control will be measured using HbA1c and downloaded information from the hybrid closed loop system. Participants will also complete questionnaires and a reflective diary.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Use of Control-IQ Technology 2.0 in Adults, Children, and Preschoolers With Type 1 Diabetes
NCT05683392
The Real-World Control-IQ Glycemic Control and Quality of Life Study in Type 1 Diabetes in France
NCT07211126
A Randomized Trial Evaluating Control-IQ+ Technology in Adults With Type 2 Diabetes
NCT05785832
Control-IQ Technology for High Insulin Users With Type 1 Diabetes (Higher-IQ)
NCT05422053
The International Diabetes Closed Loop (iDCL) Trial: Clinical Acceptance of the Artificial Pancreas
NCT03563313
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
People with Type 1 diabetes cannot make insulin to control their blood glucose. Insulin is therefore required as treatment. This is given subcutaneously by injection or using an infusion pump. Both background insulin is required and boluses of insulin given when carbohydrate is eaten.
It is difficult to accurately calculate and deliver the correct amount of insulin. More recently standard treatment involved giving one of two injections of long acting insulin and more frequent injections of fast acting insulin when carbohydrate is ingested. The dose of insulin is determined by measuring the ambient glucose level, knowing the amount of carbohydrate in any meal and predicting activity during the subsequent four or five hours.
Insulin pumps can be used to provide a pre-tuned variable background insulin infusion with manual intervention to deliver boluses of insulin with food.
In Scotland many people have now replaced finger prick glucose testing with flash glucose monitoring. This uses a small subcutaneous needle that senses subcutaneous glucose levels and, when scanned this sensor will provide a measure of subcutaneous glucose and information on the last 8 hours of glucose values (Flash Glucose monitoring). This system does not currently link to an insulin pump.
The Tandem insulin pump has recently become available in NHS Scotland for those already established on pump therapy.
The Dexcom G6 continuous glucose monitoring (CGM) system provides continuous glucose monitoring (without requiring any scanning by the patient) but is not currently funded within NHS Scotland, except for special circumstances. This system does communicate via bluetooth with the T-slim insulin pump.
The Tandem Control IQ insulin delivery system uses the link between the dexcom glucose sensor and pump to control the background insulin delivery and has been shown to work well in those studied. Patients still have to administer insulin when ingesting carbohydrate. This system is described as a hybrid closed loop system.
Problems that can potentially occur using this system include loss of communication between sensor and pump (bluetooth or wired connection), the algorithm not working or glucose readings out with the set ranges resulting in the automatic system turning off.
It is also unknown how acceptable the 'loss of control' is to a more general diabetes population as individuals with diabetes are used to making all the insulin dose decisions very frequently across each day. Confidence in these systems, both by patients and clinicians will be vital if these are to be introduced into more general use.
Therefore, the potential for these systems to have a major impact for people with diabetes is clear, but further understanding of the effectiveness and acceptability of such systems in the Scottish population is required.
The Investigator's aim is to investigate the effect of this system compared to current 'best practice' in Scotland, to gain experience in using this system and to investigate the acceptability of this system in the Scottish population.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_CONTROL
PROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Tandem Control IQ Hybrid Closed Loop Insulin Delivery System
The Tandem Control IQ hybrid closed loop insulin delivery system is made up of an externally worn Tandem insulin pump which communicates wirelessly to the Dexcom G6 CGM worn as a patch on the skin. The CGM measures glucose levels transmitting them into the computer within the pump. The computer then calculates how much insulin is required then dose delivery completes the cycle. The Control-IQ™ advanced technology adjusts insulin delivery to avoid glycaemic excursions, while still allowing the user to manually bolus at mealtimes.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Established on the Tandem pump for at least 1 month, using novorapid or humalog insulin
* HbA1c 40-90 mmol/mol inclusive within the previous 30 days or taken at screening
* Total daily dose of insulin 10-100 units
* Willing to attend study visits and complete all study assessments
* Able to give informed consent
Exclusion Criteria
* Any disorder which, in the investigators' opinion might jeopardise the patient's safety or compliance with the protocol
* Life expectancy less than one year
* Severe renal impairment (eGFR \<30ml/min)
* Weight \<25kg
* Patients prescribed hydroxycarbamide
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
DexCom, Inc.
INDUSTRY
NHS Lothian
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
John McKnight
Role: PRINCIPAL_INVESTIGATOR
NHS Lothian
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Professor John McKnight
Edinburgh, Lothian, United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
299847
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.