Safety and Efficacy of a Multi-branched Thoracoabdominal Stent Graft System for Thoracoabdominal Aortic Aneurysm.
NCT ID: NCT05054985
Last Updated: 2025-06-22
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
NA
73 participants
INTERVENTIONAL
2021-11-12
2028-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Thoracoabdominal Aortic Stent System for Endovascular Treatment of Thoracoabdominal Aortic Dissecting Aneurysm.
NCT05803564
Safety and Efficacy of Multiple Overlapping Uncovered Stents for Pararenal Aortic Aneurysm Repair
NCT01985906
A Triple-branched Stent Graft for Aute Debakey Type I Dissection Surgery
NCT06492980
Study on the Trans-Carotid Artery Occlusion Shunt System
NCT06924593
Clinical Trial of BAO-G Technique in Complex Aortic Aneurysm Endovascular Repair (BAO-G-02)
NCT07141251
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Intervention arm
Patients with thoracoabdominal aortic aneurysms, and passed the screening and signed the informed consent form.
Multi-Branched Thoracoabdominal Stent Graft System
Patients who meet all the inclusion criteria and don't meet the exclusion criteria will be implanted with multi-branched thoracoabdominal stent graft system .
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Multi-Branched Thoracoabdominal Stent Graft System
Patients who meet all the inclusion criteria and don't meet the exclusion criteria will be implanted with multi-branched thoracoabdominal stent graft system .
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Diagnosed as thoracoabdominal aortic aneurysm (based on modified Crawford classification and 2019 European Guidelines for the Treatment of Aortic aneurysm) and should meet at least one of the following conditions;
1. Maximum diameter of thoracoabdominal aortic aneurysm\>50mm;
2. The diameter has increased by more than 5mm in recent 6 months or the by more than 10mm in recent 1 year;
3. anatomical criteria
1. The proximal anchoring region (aorta or implanted graft) was 17\~36 mm in diameter and ≥25 mm in length;
2. Distal anchoring region (aorta or implanted graft): If the distal anchoring region is in the iliac artery, the anchoring region has a diameter range of 7\~25 mm and a length of ≥15 mm; If the distal anchoring area is in the abdominal aorta, the diameter of the anchoring area ranges from 12\~36mm and the length≥ 20mm;
3. The diameter of the vessel anchoring area of the visceral branch ranges from 6\~13 mm and the length ≥15 mm;
4. The diameter of renal artery anchoring area ranges from 4.5\~9mm, and the length ≥15 mm;
5. Appropriate iliac, femoral and upper limb artery access;
4. Patients who can understand the purpose of the trial, voluntarily participate and sign the informed consent, and are willing to complete the follow-up according to the requirements of the protocol;
Exclusion Criteria
2. Thoracoabdominal aortic dissection;
3. Mycotic or infectious thoracoabdominal aortic aneurysm;
4. Patients whose systemic or local infection may increase the risk of intravascular graft infection;
5. Superior mesenteric, celiac, or renal artery occlusion;
6. Requiring simultaneous coverage and embolization of bilateral internal iliac arteries;
7. Severe stenosis, calcification, or mural thrombus in the anchoring area of the stent tend to have difficulty in attachment of the stent-graft or affect the patency of the stent;
8. A history of acute coronary syndrome within 6 months; Acute coronary syndrome is defined as an acute ischemic syndrome of the heart resulting from the rupture or erosion of unstable intracoronary atherosclerotic plaques followed by fresh thrombosis, including ST-segment elevation myocardial infarction, non-ST-segment elevation myocardial infarction, and unstable angina pectoris.
9. Transient ischemic attack (TIA) or ischemic/haemorrhagic stroke within 3 months;
10. Preoperative liver renal function abnormalities (ALT or AST ≥ 5 times the upper limit of normal value), or serum creatinine ≥ 150 μmol/L;
11. Severe pulmonary insufficiency who cannot tolerate general anaesthesia;
12. Severe coagulation dysfunction;
13. Undergone major surgical or interventionic surgery within 30 days before surgery;
14. A history of allergy to contrast agents, anticoagulants, antiplatelet drugs, stents, and conveyor materials (nitinol, polyester, PTFE, nylon);
15. Connective tissue diseases such as systemic lupus erythematosus, Marfan's syndrome, Adam's syndrome, or Behcet's disease;
16. takayasu arteritis;
17. Serious vital organ dysfunction or other serious disease;
18. Planning pregnancy, pregnancy, or breastfeeding;
19. Patients who participated in other clinical trials and was not discontinued or withdrawn within the first 3 months of the screening period of this trial.
20. Life expectancy less than 1 year;
21. Patients who, in the judgment of the investigator, are not eligible for endotherapy.
18 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Lifetech Scientific (Shenzhen) Co., Ltd.
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Wei Guo, Professor
Role: PRINCIPAL_INVESTIGATOR
Chinese PLA General Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Chinese PLA General Hospital
Beijing, Beijing Municipality, China
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Wei Guo
Role: primary
References
Explore related publications, articles, or registry entries linked to this study.
Ge Y, Zhang H, Rong D, Liu F, Jia X, Xiong J, Ma X, Wang L, Fan T, Guo W. Protocol for GUo's renovisceral Artery reconstruction-1: a prospective, multicentre, single-arm clinical trial to evaluate the safety and efficacy of a multibRANched sTEnt graft systEm for thoracoabdominal aortic aneurysm (GUARANTEE study). BMJ Open. 2022 Mar 23;12(3):e059401. doi: 10.1136/bmjopen-2021-059401.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
XJ-TAAA-01
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.