AI Algorithms to Automate the TMI by VMAT Optimization Using WB-CT/MRI and Synthetic WB-CT - The AuToMI Project
NCT ID: NCT04976205
Last Updated: 2026-01-21
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
60 participants
INTERVENTIONAL
2021-06-15
2025-08-08
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Actually, the time required to optimize a TMI/TMLI plan is 10 days. Therefore, the simulation Computed Tomography (CT) is performed many days before the BMT. Furthermore, the lymph-nodes are defined only on CT images.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Optimization of Radiotherapy in Treatment of Painful Bone Metastasis
NCT00610272
Exploring Photon-Counting CT for Enhanced Target Delineation and Dose Accuracy in Personalized Radiotherapy - ANTHEM
NCT07098247
A Phase II Single-arm Study of Total Body Irradiation With Linac Based VMAT and IGRT
NCT04509765
Biological Image Guided Antalgic Stereotactic Body Radiotherapy of Bone Metastases
NCT01429493
Short Course Radiotherapy in Complicated Bone Metastases Palliation
NCT03455231
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The TBI target is represented by the whole BM, and eventually the whole lymphatic system, liver, spleen. Usually, a very simple geometry is adopted, with patient positioned on a dedicated couch at 3-4 meters away from the linear accelerator to fully cover the target with a single beam, avoiding field junctions.
The increased life expectancy revealed the occurrence of important toxicities because of full doses received by organs at risk (OARs) and this limited the use of TBI as stated by the 2018 ILGROG guidelines. Many groups have, therefore, explored the possibility of sophisticated techniques for reducing the dose to healthy tissues while increasing the dose to the BM. These newer approaches aim to generate total marrow (lymph-node) irradiation (TMI/TMLI), sparing as much as possible non-skeletal and non-lymphoid structures.
Preliminary clinical data on phase I/II trials support the use of TMI/TMLI as part of conditioning for BMT for relapsed-refractory acute leukemia patients and multiple myeloma. However, TMI/TMLI adoption is still very limited to few skilled hospitals due to the extreme difficulty in the planning that needs many days.
The evaluation of TMI/TMLI with Volumetric Modulated Arc Therapy (VMAT) was started in our institute in 2009 and we treated around 90 patients in 10 years.
VMAT-TMI/TMLI requires multiple arcs from isocenters with different positions to fully include the patient length. Therefore, many field junctions between arcs with different isocenters should be managed. Furthermore, the CT length does not allow to acquire the patient in a single CT scan. Two CT series must be acquired and co-registered.
Actually, the time required to optimize a TMI/TMLI plan is 10 days. Therefore, the simulation Computed Tomography (CT) is performed many days before the BMT. Furthermore, the lymph-nodes are defined only on CT images.
Deep learning (DL) artificial intelligence (AI) algorithms in medical imaging and RT are rapidly expanding. DL focused on lesion detection and classification by features extraction. Image segmentations using fully convolutional network (FCN), holistically nested network (HNN) or other customized network architectures were implemented in many regions.
Over the past decades, the use of magnetic resonance imaging (MRI) to support RT has increased. MRI provides excellent soft-tissue imaging that could improve the target definition. The lymph-nodes contouring, based on MRI, will result in smaller target, enabling a better sparing of healthy tissues. Moreover, MRI significantly reduces inter/intra-observer contouring variability. At this aim, new generation MRI consoles with larger bore size, flat tabletops and dedicated imaging protocols with reduced image distortion to \<1 mm were developed. Moreover, newly developed gradient-echo 3D sequences, and dedicated coils, can be used for producing a whole body WB-MRI acquisition in a few minutes. Furthermore, synthetic CT from MRI was proposed and implemented in some regions (i.e. brain and prostate) to substitute the CT for providing electron density information for dose planning calculation.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
TMI/TMLI
The standard planning optimization for TMI/TMLI preview a two-free-breathing-CT scan without contrast will be performed for simulation at day -15(-10) to the BMT. The same day a WB-MRI will be acquired for lymph-nodes delineation. WB-MRI scans will be performed using a 1.5T MR scanner. The two CT will be co-registered to the WB-MRI.
CTV will be manually defined as the bones excluding mandible and hands (CTVBones), the spleen (CTVSpleen), and lymph nodes (CTVLN) using both MRI and CT images. The day -3 (4) to the BMT, further two-CT series will be acquired and co-registered to the first CTs for dose verification. Pre-treatment quality assurance (QA) will be performed the day before the treatment using the standard internal procedure.
The treatment will be performed the day before the BMT.
Total Marrow (Lymph-node) Irradiation
To the standard procedure for TMI/TMLI target definition, based on simulation WB-CT acquired 10/15 days before BMT, we acquire: WB- magnetic resonance imaging (MRI) the same day of the simulation WB-CT. A verification WB-CT will be performed 3/4 days before the delivery. Plans will be optimized with Volumetric Modulated Arc Therapy (VMAT) technique.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Total Marrow (Lymph-node) Irradiation
To the standard procedure for TMI/TMLI target definition, based on simulation WB-CT acquired 10/15 days before BMT, we acquire: WB- magnetic resonance imaging (MRI) the same day of the simulation WB-CT. A verification WB-CT will be performed 3/4 days before the delivery. Plans will be optimized with Volumetric Modulated Arc Therapy (VMAT) technique.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Adult patients aged ≥18 years
* Diagnosis of Hematological disease
* Eligibility for allogeneic stem cell transplantation as center guidelines
* TMI/TLI as part of the conditioning regimen
Exclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Istituto Clinico Humanitas
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
IRCCS Humanitas Research Center
Rozzano, Milano, Italy
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Dei D, Lambri N, Sopranzi C, Galdieri C, Franzese C, Scorsetti M, Mancosu P. Impact of reduced interval from simulation CT to treatment delivery on dosimetric and positioning accuracy for total marrow lymph-node irradiation. Strahlenther Onkol. 2025 Jun 13. doi: 10.1007/s00066-025-02415-x. Online ahead of print.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2928
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.