Remote Glucose Monitoring in Hospital Settings

NCT ID: NCT04797208

Last Updated: 2023-02-13

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

30 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-01-09

Study Completion Date

2023-08-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Use of real-time continuous glucose monitoring (RT-CGM) systems in inpatient settings especially during the COVID-19 pandemic, may allow hospital staff to remotely monitor glucose while reducing viral exposure and preserving use of PPE. RT-CGM may be of benefit to inpatients with unstable glycaemia and at risk of severe hypoglycaemia, as it can automatically alert the treating clinical team of hypo and hyperglycaemia. This is of clinical relevance as up to 45% of inpatients with diabetes were found to have asymptomatic hypoglycaemia events in hospital, especially overnight. It may therefore provide a safer method of monitoring glycaemia in hospital compared to conventional bedside capillary glucose testing, by minimising the likelihood of hyper- and hypoglycaemic events and their known associated worse outcomes.

The aim of this pilot study is to to demonstrate that use of Dexcom G6 RT-CGM may provide a safer and effective method of monitoring glycemia in hospital. Data from this pilot study will be used to design and implement a larger multi-centre pivotal trial.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Hyperglycaemia in hospitalized patients is becoming a common clinical problem due to the increasing prevalence of diabetes mellitus. Hyperglycaemia in this cohort can also occur in patients with previously undiagnosed diabetes, or during acute illness in those with previously normal glucose tolerance. A growing body of evidence currently suggest that the degree of hyperglycaemia upon admission and the duration of hyperglycaemia during their illness are associated with adverse outcomes. In-patient hyperglycaemia is now widely recognised as a poor prognostic marker in terms of morbidity and mortality, increased length of stay and cost to the healthcare system. Analysis of data from nine randomised controlled trials and ten observational studies reported that treatment of hyperglycaemia in non-critically ill patients was associated with reduction in the risk of infection (relative risk, 0.41;95% confidence interval, 0.21-0.77).

The current management of inpatient hyperglycaemia in non-critical care is still far from ideal, and vary widely between different centres . The discordance between clinical evidence and practice is due to a number of factors which could potentially undermine patient care and safety. Of these, hypoglycaemia remains one the biggest barriers to managing in-patient hyperglycaemia. Hypoglycaemia is associated with increased length of stay (up to 2.3 times higher) and inpatient mortality. A recent meta-analyses reported that intensive glycaemic control on non-critical care patients is associated with a trend of increased risk of hypoglycaemia. Optimal glycaemic inpatient glucose targets still remain an intensely debated subject. Consensus from the American Association of Clinical Endocrinologists (AACE) and American Diabetes Association (ADA) recommended specified targets for hospitalised patients, of fasting or pre-meal blood glucose \<7.8mmol/l and random blood glucose \<10mmol/l.

Outpatient use of real-time continuous glucose monitoring (RT-CGM) is gradually increasing. Its implementation in the outpatient setting has been supported by robust scientific and clinical studies, showing benefits in glycaemic control, minimising hypoglycaemia and improving patient experience. Extending use of RT-CGM systems to inpatient settings especially during the COVID-19 pandemic may allow hospital staff to remotely monitor glucose while reducing viral exposure through frequent patient contact and preserving personal protective equipment (PPE). RT-CGM may be of benefit to inpatients with unstable glycemia (i.e. COVID-19 patients receiving dexamethasone therapy) and at risk of severe hypoglycemia, as it can automatically alert the treating clinical team of hypo- and hyperglycemia. Use of RT-CGM in hospital could therefore potentially benefits patients by improving their glycaemic control, and healthcare professionals working in busy general ward settings by providing remote real-time glucose monitoring from the patient every 10 minutes.

The main objective of this study is to assess the efficacy of RT-CGM in maintaining glucose levels within the target range (5.6 to 10.0 mmol/l) compared to conventional glucose monitoring in hospitalised insulin-treated T2D. Other objectives include evaluating safety of RT-CGM in terms of reducing the incidence of hypoglycaemia, severe hyperglycaemia, and collecting feedback of participants and healthcare professionals using RT-CGM in the general ward settings.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Diabetes Mellitus, Type 2 Hyperglycemia Stress Hypoglycemia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Real-Time CGM

This group will have a subcutaneous RT-CGM inserted by a member of the research team. CGM's low and high glucose alerts will be activated. The treating clinical team will be able to remotely monitor glucose data and be notified of low glucose alerts through the linked handset. Hyper- and hypo-glycemia management including insulin dose adjustments by the treating clinical team, will be guided by sensor glucose levels and trends according to written guidelines during the study. Glucose level during and post-hypoglycaemia treatment will be confirmed by capillary blood glucose (CBG) measurements (using the NovaStat® glucometer or similar CE-marked glucose meter).

Group Type EXPERIMENTAL

Real-Time CGM

Intervention Type DEVICE

Participants will be wearing a real-time continuous glucose sensor which will enable their glucose levels to be remotely monitored. High and Low glucose alerts will also be available.

Capillary blood glucose with masked CGM

This group will have their glucose monitored in hospital using the NovaStat® glucometer or similar CE-marked glucose meter) and insulin dose adjusted by the treating clinical team as per usual hospital guidelines. A masked subcutaneous CGM will be inserted by a member of the research team to collect glucose values (glucose values will not be displayed and no glucose alerts will be available). This will removed at the end of the study by the research team.

Group Type ACTIVE_COMPARATOR

Capillary blood glucose testing with masked CGM

Intervention Type DEVICE

Participants will have their glucose monitored in hospital in the conventional manner using the NovaStat® glucometer or similar CE-marked glucose meter) and insulin dose adjusted by the treating clinical team as per usual hospital guidelines. A masked subcutaneous CGM will be inserted for data collection only.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Real-Time CGM

Participants will be wearing a real-time continuous glucose sensor which will enable their glucose levels to be remotely monitored. High and Low glucose alerts will also be available.

Intervention Type DEVICE

Capillary blood glucose testing with masked CGM

Participants will have their glucose monitored in hospital in the conventional manner using the NovaStat® glucometer or similar CE-marked glucose meter) and insulin dose adjusted by the treating clinical team as per usual hospital guidelines. A masked subcutaneous CGM will be inserted for data collection only.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Aged 18 years or older
2. Diagnosed with Type 2 diabetes
3. Currently receiving treatment with subcutaneous insulin alone, or in combination with oral glucose-lowering medication(s)
4. At least one CBG level \> 10mmol/l
5. Have the ability to consent in English

Exclusion Criteria

1. Autoimmune type 1 diabetes
2. Known or suspected allergy against insulin
3. Current or planned pregnancy or breast feeding
4. Current in-patient in intensive care unit
5. Planned surgery during study period
6. Any physical or psychological disease or medication(s) likely to interfere with the conduct of the study and interpretation of the study results, as judged by the study clinician.
7. Likely discharge earlier than 72 hours
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Manchester Academic Health Science Centre

OTHER

Sponsor Role collaborator

Manchester University NHS Foundation Trust

OTHER_GOV

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Manchester Royal Infirmary

Manchester, Greater Manchester, United Kingdom

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

United Kingdom

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Mohammed Nazir

Role: CONTACT

0161 901 3560

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Mohammed Nazir

Role: primary

0161 901 3560

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

B01121

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

RT-CGM in Young Adults at Risk of DKA
NCT04039763 RECRUITING NA
Examining The Role of CGM in T2DM
NCT01614262 COMPLETED NA
Time in Glucose Hospital Target
NCT05135676 COMPLETED NA