The Pediatric Artificial Pancreas (PEDAP) Trial of Control-IQ Technology in Young Children in Type 1 Diabetes

NCT ID: NCT04796779

Last Updated: 2023-06-28

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

102 participants

Study Classification

INTERVENTIONAL

Study Start Date

2021-04-21

Study Completion Date

2022-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to learn whether an investigational automated insulin delivery system ("study system") for young children (2 yo to less than 6 yo) with type 1 diabetes can safely improve blood glucose (sometimes called blood sugar) control.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Participants will be randomized to closed loop control (CLC) system (t:slim X2 with Control-IQ Technology) or to standard of care where the children will continue to use his or her personal insulin pump or multiple daily injections. Both groups will use a continuous glucose monitor (CGM) throughout the study. The study system will also use a study insulin pump and a software algorithm to automatically give insulin and control blood glucose. This system is also sometimes called a "closed-loop" system.

This study will take about 6-7 months for the child to complete. Study visits can be completed from home via videoconference (e.g. Zoom) without visiting the clinic or in-person at the clinic.

A subset of participants will be asked to join an ancillary study with Meal Bolus and Exercise challenges during the extension phase. Data collected from the start of each of these challenges until the following morning will be excluded from the analysis of the extension phase.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Type 1 Diabetes

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

CLC Group

Participants who skip or successfully complete the run-in will be randomly assigned 2:1 to the use of closed-loop control (CLC group) system using Tandem t:slim X2 with Control-IQ Technology vs Standard of Care (SC group) for 3 weeks. Participants randomized to the intervention group will use the Tandem t:slim X2 with Control-IQ Technology v1.0 during the first 13 weeks of the study (RCT phase, weeks 1-13) and then use Tandem t:slim X2 insulin pump with Control-IQ Technology v1.5 for the remaining 13 weeks of the study (extension phase, weeks 14-26).

Group Type EXPERIMENTAL

Tandem t:slim X2 with Control-IQ Technology Pro

Intervention Type DEVICE

The Tandem t:slim X2 with Control-IQ Technology Pro is an "artificial pancreas" (AP) application that uses advanced closed loop control algorithms to automatically manage blood glucose levels for people with Type 1 Diabetes. The system modulates insulin to keep blood glucose in a targeted range. The system components include the t:slim X2 with Control-IQ Technology and the Dexcom G6 CGM. The system is very similar to the commercially available t:sli X2 with Control-IQ but modified to accept the lower weight and Total Daily Insulin of the studied population.

Tandem t:slim X2 with Control-IQ Technology V1.5

Intervention Type DEVICE

The Tandem t:slim X2 with Control-IQ Technology V1.5 is an "artificial pancreas" (AP) application that uses advanced closed loop control algorithms to automatically manage blood glucose levels for people with Type 1 Diabetes. The system modulates insulin to keep blood glucose in a targeted range. The system components include the t:slim X2 with Control-IQ Technology and the Dexcom G6 CGM. The system is derived from the commercially available t:slim X2 with Control-IQ, with additional features.

SC Group

Participants who skip or successfully complete the run-in will be randomly assigned 2:1 to the use of closed-loop control (CLC group) system using Tandem t:slim X2 with Control-IQ Technology vs Standard of Care (SC group) for 3 weeks. Participants randomized to the SC group will use their existing insulin therapy in conjunction with study Dexcom G6 CGM during the first 13 weeks of the study (RCT phase, weeks 1-13). The SC group will then transition to using the Tandem t:slim X2 insulin pump with Control-IQ Technology v1.5 and study Dexcom G6 CGM for the remaining 13 weeks of the study (weeks 14-26).

Group Type ACTIVE_COMPARATOR

Standard Care (SC)

Intervention Type DEVICE

Standard of Care consists in the participant existing insulin therapy (prior to enrollment) in conjunction with a study Dexcom G6 CGM. Existing insulin therapies are defined as multiple daily injections of insulin (MDI) or use of an insulin pump without hybrid closed-loop control capabilities (low-glucose suspend or predictive low-glucose suspend functionality is permitted).

Tandem t:slim X2 with Control-IQ Technology V1.5

Intervention Type DEVICE

The Tandem t:slim X2 with Control-IQ Technology V1.5 is an "artificial pancreas" (AP) application that uses advanced closed loop control algorithms to automatically manage blood glucose levels for people with Type 1 Diabetes. The system modulates insulin to keep blood glucose in a targeted range. The system components include the t:slim X2 with Control-IQ Technology and the Dexcom G6 CGM. The system is derived from the commercially available t:slim X2 with Control-IQ, with additional features.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Tandem t:slim X2 with Control-IQ Technology Pro

The Tandem t:slim X2 with Control-IQ Technology Pro is an "artificial pancreas" (AP) application that uses advanced closed loop control algorithms to automatically manage blood glucose levels for people with Type 1 Diabetes. The system modulates insulin to keep blood glucose in a targeted range. The system components include the t:slim X2 with Control-IQ Technology and the Dexcom G6 CGM. The system is very similar to the commercially available t:sli X2 with Control-IQ but modified to accept the lower weight and Total Daily Insulin of the studied population.

Intervention Type DEVICE

Standard Care (SC)

Standard of Care consists in the participant existing insulin therapy (prior to enrollment) in conjunction with a study Dexcom G6 CGM. Existing insulin therapies are defined as multiple daily injections of insulin (MDI) or use of an insulin pump without hybrid closed-loop control capabilities (low-glucose suspend or predictive low-glucose suspend functionality is permitted).

Intervention Type DEVICE

Tandem t:slim X2 with Control-IQ Technology V1.5

The Tandem t:slim X2 with Control-IQ Technology V1.5 is an "artificial pancreas" (AP) application that uses advanced closed loop control algorithms to automatically manage blood glucose levels for people with Type 1 Diabetes. The system modulates insulin to keep blood glucose in a targeted range. The system components include the t:slim X2 with Control-IQ Technology and the Dexcom G6 CGM. The system is derived from the commercially available t:slim X2 with Control-IQ, with additional features.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Clinical diagnosis, based on investigator assessment, of type 1 diabetes for at least 6 months and using insulin for at least 6 months
2. Familiarity and use of a carbohydrate ratio for meal boluses.
3. Age ≥2 and \<6 years old
4. Living with one or more parent/legal guardian knowledgeable about emergency procedures for severe hypoglycemia and able to contact emergency services and study staff.
5. Investigator has confidence that the parent can successfully operate all study devices and is capable of adhering to the protocol
6. Willingness to switch to lispro (Humalog) or aspart (Novolog) if not using already, and to use no other insulin besides lispro (Humalog) or aspart (Novolog) during the study for participants using a study-provided Tandem pump during the study.

• Study will not be providing insulin; therefore, participants will need to have access to either lispro or aspart
7. Total daily insulin dose (TDD) at least 5 U/day
8. Body weight at least 20 lbs.
9. Willingness not to start any new non-insulin glucose-lowering agent during the course of the trial (see section 2.3)
10. Participant and parent(s)/guardian(s) willingness to participate in all training sessions as directed by study staff.
11. Parent/guardian proficient in reading and writing English.

Exclusion Criteria

1. Concurrent use of any non-insulin glucose-lowering agent (including Glucagon-like peptide-1 \[GLP-1\] agonists, Symlin, Dipeptidyl peptidase-4 \[DPP-4\] inhibitors, Sodium-glucose Cotransporter-2 (SGLT-2) inhibitors, sulfonylureas).
2. Hemophilia or any other bleeding disorder
3. History of \>1 severe hypoglycemic event with seizure or loss of consciousness in the last 3 months
4. History of \>1 DKA event in the last 6 months not related to illness, infusion set failure, or initial diagnosis
5. History of chronic renal disease or currently on hemodialysis
6. History of adrenal insufficiency
7. Hypothyroidism that is not adequately treated
8. Use of oral or injectable steroids within the last 8 weeks
9. Known, ongoing adhesive intolerance
10. Plans to receive blood transfusions or erythropoietin injections during the course of the study
11. A condition, which in the opinion of the investigator or designee, would put the participant or study at risk (specified in the study procedure manual)
12. Currently using any closed-loop system, or using an insulin pump that is incompatible with use of the study CGM
13. Participation in another pharmaceutical or device trial at the time of enrollment or during the study
14. Employed by, or having immediate family members employed by Tandem Diabetes Care, Inc., or having a direct supervisor at place of employment who is also directly involved in conducting the clinical trial (as a study investigator, coordinator, etc.); or having a first-degree relative who is directly involved in conducting the clinical trial
Minimum Eligible Age

24 Months

Maximum Eligible Age

71 Months

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)

NIH

Sponsor Role collaborator

Jaeb Center for Health Research

OTHER

Sponsor Role collaborator

Tandem Diabetes Care, Inc.

INDUSTRY

Sponsor Role collaborator

Marc Breton

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Marc Breton

Principal Investigator

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

John Lum, MS

Role: STUDY_DIRECTOR

Jaeb Center for Health Research

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Stanford University

Stanford, California, United States

Site Status

Barbara Davis Center, University of Colorado

Aurora, Colorado, United States

Site Status

University of Virginia Center for Diabetes Technology

Charlottesville, Virginia, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Wadwa RP, Reed ZW, Buckingham BA, DeBoer MD, Ekhlaspour L, Forlenza GP, Schoelwer M, Lum J, Kollman C, Beck RW, Breton MD; PEDAP Trial Study Group. Trial of Hybrid Closed-Loop Control in Young Children with Type 1 Diabetes. N Engl J Med. 2023 Mar 16;388(11):991-1001. doi: 10.1056/NEJMoa2210834.

Reference Type BACKGROUND
PMID: 36920756 (View on PubMed)

Beck RW, Kanapka LG, Breton MD, Brown SA, Wadwa RP, Buckingham BA, Kollman C, Kovatchev B. A Meta-Analysis of Randomized Trial Outcomes for the t:slim X2 Insulin Pump with Control-IQ Technology in Youth and Adults from Age 2 to 72. Diabetes Technol Ther. 2023 May;25(5):329-342. doi: 10.1089/dia.2022.0558. Epub 2023 Apr 12.

Reference Type DERIVED
PMID: 37067353 (View on PubMed)

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol

View Document

Document Type: Statistical Analysis Plan

View Document

Document Type: Informed Consent Form

View Document

Related Links

Access external resources that provide additional context or updates about the study.

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

1U01DK127551-01

Identifier Type: NIH

Identifier Source: secondary_id

View Link

RFA-DK-19-036

Identifier Type: OTHER_GRANT

Identifier Source: secondary_id

200433

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.