The Effectiveness of FRAME FR for AVF Repair in High-Flow Reduction & Stabilization, A Prospective Trial
NCT ID: NCT04795401
Last Updated: 2023-09-13
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
21 participants
INTERVENTIONAL
2021-04-06
2024-04-05
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
High flow fistulas significantly increase the risk for the development of high output cardiac failure, skin breakdown, bleeding, hand ischemia, and other systemic complications. In cases of high flow AVF, venous reconstruction procedures, banding and/or plication, are often required to limit venous diameter and flow. The longevity of this procedure is limited as the reconstructed segment remodels and re-dilates due to ongoing arterial pressure. Banding and plication are both procedures that are designed to increase resistance to flow. Banding is performed by wrapping a segment of polytetrafluoroethylene (PTFE) around the outflow tract of the fistula, or by placing a suture around the fistula near the arterial anastomotic area to create a narrowing. Fistula plication involves narrowing of a short segment of the proximal venous outflow tract, usually accomplished by suturing or stapling the fistula for 2-6 cm. One of the notable systemic effects of a hemodialysis AVF is an acute decrease in systemic vascular resistance with a simultaneous increase in venous return to the heart, and thus an increase of the cardiac output. Cardiac failure occurs more frequently in patients with an access flow QA\>2 l/min and CPR≥20%. Another adverse systemic effect of AV fistulas is pulmonary hypertension. The increased flow volume to the heart from an AV fistula yields an increase in pulmonary pressures. This can limit pulmonary vasodilation and result in pulmonary hypertension.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Hemodialysis Vascular Access Imaging Study
NCT02374762
Identifying Risk Factors (RF) for Early Haemodialysis Arteriovenous Fistula Failure (eAVFF)
NCT05552482
Trial Comparing the Incidence of Steal Syndrome in the Two Types of anTEcubitaL Fossa Arteriovenous fistuLa AVF
NCT02297451
Randomized Fistula Study
NCT00808561
Collateral Ligation in Failing Fistulas
NCT03365089
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
FRAME Group
Patients will be enrolled during their hospitalization/consultation in vascular surgery department. After asking questions, his given free, informed and written consent will be collected, and recorded in his medical file by the investigator.
During this hospitalization, the pre-procedure forming part of the usual care is carried out. The specific acts of research are: Cardiac echocardiography and Quality of life survey SF-36 The plication procedure will be performed according to the FRAME FR. All pre-, peri-, and post- operative routine patient management will be carried out as usual.
Follow up visits will be held at 6, 12 months post procedure. All follow up visits will include the assessments as usual.
The specific acts of research are as follows: Cardiac echocardiography at 12 months and quality of life survey SF-36.
FRAME FR IFU
The surgeon will use the medical device FRAME to perform the plication procedure. The device will be selected and implanted according to the product IFU.
Control Group
Control group corresponds to the historical patients over a period of time sufficient to have at least 20 patients according to inclusion criteria. The information form will be sent to each patient eligible for the study by post. Without any feedback from him within 30 days, it is considered that the patient does not object to the use of its data.
As part of this research, no additional examination will be performed. The data used correspond to the data collected in the usual care of patients.
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
FRAME FR IFU
The surgeon will use the medical device FRAME to perform the plication procedure. The device will be selected and implanted according to the product IFU.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patient with a fistula flow \>1.5l/min
* Patient with a hemodialysis AVF and heart failure symptoms and who may require a reduction in flow even if \<1.5l/min
* Patient whose AVF flows \<1.5l/min and who may require a flow reduction for a reduction of edema in case of central vein stenosis or symptom of steal syndrome
* Patient referred by a cardiologist for high output cardiac failure
* Patient who is able and willing to comply with the study follow up requirements
* French speaking patient
* Patient who is affiliated to a social security system
* Patient who is able and willing to give his informed written consent.
Exclusion Criteria
* Patient with AV Fistula composite (constructed or prosthetic graft and vein
* Patient with stents within the operative portion of the fistula
* Patients with known central venous stenosis or occlusion
* Patients with a hand ischemia
* Patient with wall thickness \>2 mm, with separation or thrombus within the operative portion of the fistula that cannot be removed, as determined intraoperatively
* Hypercoagulability, on chronic anticoagulation
* Pregnant and breastfeeding women
* Concomitant life-threatening disease, likely to limit life expectancy to less than two years
* Inability to tolerate or comply with required guideline based upon post-operative drug regimen
* Inability to tolerate or comply with required follow-ups
* Concurrent participation in an interventional (drug or device) study for which the follow-up is not completed
* Patient unable or unwilling to perform all the requested tasks
* Patient under tutorship or curatorship
* Patient deprived of liberty.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Fondation Hôpital Saint-Joseph
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Alexandros MALLIOS, MD
Role: PRINCIPAL_INVESTIGATOR
Fondation Hôpital Saint-Joseph
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Groupe Hospitalier Paris Saint-Joseph
Paris, , France
Countries
Review the countries where the study has at least one active or historical site.
Related Links
Access external resources that provide additional context or updates about the study.
Amerling et al. Arteriovenous Fistula Toxicity. Blood Purif 2011; 31: 113-120.
Sheaffer et al. Minimally Invasive Limited Ligation Endoluminal-Assisted Revision (MILLER): A Review of the Available Literature and Brief Overview of Alternate Therapies in Dialysis Associated Steal Syndrome. J. Clin. Med. 2018, 7, 128.
Reddy YNV, Obokata M, Dean PG, et al. Long-term cardiovascular changes following creation of arteriovenous fistula in patients with end stage renal disease. Eur Heart J 2017; 38:1913
Basile et al. The relationship between the flow of arteriovenous fistula and cardiac output in haemodialysis patients
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
FRAME-FR
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.