Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
19 participants
INTERVENTIONAL
2021-09-01
2024-04-08
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Safety and Efficacy of Remote Programming of Nucleus Cochlear Implants
NCT02644343
A Computational Approach to Optimal Deactivation of Cochlear Implant Electrodes
NCT05219474
Usability of the CP950 Sound Processor
NCT02727842
Status Telemetry for Cochlear Implantations
NCT06223724
Place-based Cochlear Implant Mapping
NCT05558514
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Cochlear implant programming (also called "mapping") is done using a set of generally-accepted default settings without taking into account individual differences of precisely where CI electrodes are physically located in the cochlea. For this reason, CI users commonly experience a place-pitch mismatch between the stimulation by an electrode in response to a given frequency and the actual frequency specified by the original cochlear location. CI users vary widely in their ability to adapt to place-pitch mismatch; some adapt completely, others partially, and others not at all. The length of time in which an individual takes to adapt is also highly variable. Bilateral CI users may have differing adaptation between ears, leading to distortion of sound localization and speech in noise perception abilities.
Flat Panel Computed Tomography (FPCT) is an imaging technique that consistently produces high quality images with identification of the delicate cochlear structures and the cochlear implant (CI) electrode contacts. FPCT imaging of the cochlea, combined with 3D curved multiplanar reconstruction (MPR) software, has been shown to yield reliable cochlear duct length measurements. With these resources, measurements of cochlear length and determination of intracochlear electrode location relative to standardized cochlear landmarks can be produced. These data are then utilized to create individualized frequency allocation tables relevant to the actual physical location of CI electrode contacts.
In this study, FPCT imaging, 3D curved MPR, and applied mathematics are used to quantify the difference between theoretical and actual electrode contact placement with respect to pitch-place mapping. Previous results have revealed significant deviations between predicted and programmed characteristic frequencies, which are relevant for accurate speech, pitch, and music perception. The goal of the study is to gather FPCT scans on a cohort of 20 new CI recipients, and characterize the impact of long-term (1 year) personalized pitch-place maps on a battery of speech and music metrics. The performance with the FPCT-based programs will then be compared to performance using the manufacturer default settings.
The novel aspect of this study involves working with newly implanted CI recipients and programming these patients with custom CT-based programs. More specifically, CT-based programs will be given to new CI recipients before any acclimation or programming of clinical default maps occur. This differentiates the study from prior ones, as CT-based programming has only been investigated in populations who have already used clinical default maps for some substantial period of time (e.g. for 3 months, 5 years, etc.). Participants will participate in a series of testing sessions to evaluate their speech and music perception abilities over the course of the study. At the end of the study, participants will be allowed to keep their preferred listening programs (i.e., experimental and/or default program).
The researcher team hypothesizes that bypassing the use of a clinical-based map is imperative to fully understanding the effects of CT-based programming, as those who have already used clinical default programs demonstrate much higher degrees of place-pitch mismatch at baseline. By providing a new CI recipient with a custom CT-based program on their very first day of electrical hearing (CI activation), there is a unique and novel opportunity to minimize pitch-place mismatch from the outset, and to bypass the period of time that the vast majority of CI recipients have when first adapting to a clinical default program.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
Participants may have the experimental programs uploaded to their CI and use these programs to listen to speech and music stimuli and provide feedback. The participants may be asked to listen to these programs for acute and/or chronic periods of time. Participants may also have their performance on speech and music assessments measured using a clinical default program.
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
CT-Based Program for First Year of CI Use
The Flat Panel CT scan will take place after a CI has been implanted and prior to the CI device activation.
The CI device will be activated using a CT-based program. The participant may continue to use this program for 1 year. Speech and music perception abilities will be monitored at regular intervals (approx. at 1, 3, 6, and 12 months post-activation).
After the 1 year of experimental program use, the participant may be switched over to a program that uses only the clinical default settings for 1 month; after which the participant will again complete the speech and music test battery.
At the end of the 13 month study the participant may choose whether to use the CT-based program or the clinical default program moving forward.
CT Guided Cochlear Implant Programming
Flat Panel (high resolution) CT scans of the temporal bones, including the inner ears, will be obtained. The research team will use the scans to generate custom cochlear implant (CI) programs for use by the participants.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
CT Guided Cochlear Implant Programming
Flat Panel (high resolution) CT scans of the temporal bones, including the inner ears, will be obtained. The research team will use the scans to generate custom cochlear implant (CI) programs for use by the participants.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Has not yet had their CI activated
* Be able and willing to participate in all of the research appointments for follow-up testing (e.g., 1, 3, 6, 12, and 13 months post-CI activation)
* Be willing to use the CI full-time (during waking hours) for 13 months post-activation
* Is able to speak and read American English
* Uses oral/aural communication as primary communication modality
Exclusion Criteria
* Partially-inserted CI with fewer than 10 intra-cochlear electrodes
* Any concomitant condition(s) that may affect performance on speech and music test battery (e.g., cognitive impairment)
* Atypical cochlear anatomy (e.g., fewer than 2 turns of the cochlea)
* Pregnancy (a contraindication for CT scan)
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of California, San Francisco
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Charles J Limb, MD
Role: PRINCIPAL_INVESTIGATOR
University of California, San Francisco
Melanie L Gilbert, AuD
Role: STUDY_DIRECTOR
University of California, San Francisco
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of California, San Francisco
San Francisco, California, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Jiam NT, Pearl MS, Carver C, Limb CJ. Flat-Panel CT Imaging for Individualized Pitch Mapping in Cochlear Implant Users. Otol Neurotol. 2016 Jul;37(6):672-9. doi: 10.1097/MAO.0000000000001060.
Jiam NT, Gilbert M, Cooke D, Jiradejvong P, Barrett K, Caldwell M, Limb CJ. Association Between Flat-Panel Computed Tomographic Imaging-Guided Place-Pitch Mapping and Speech and Pitch Perception in Cochlear Implant Users. JAMA Otolaryngol Head Neck Surg. 2019 Feb 1;145(2):109-116. doi: 10.1001/jamaoto.2018.3096.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
15-17575
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.