Anatomical Study of Aorta Balloon Occlusion Based on CT Angiography
NCT ID: NCT04440904
Last Updated: 2020-06-22
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
57 participants
OBSERVATIONAL
2019-04-01
2019-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Multi-detector Computer Tomography Protocol Project: Chest Imaging Technique and Case Presentation
NCT01206751
Aortic Dissection With 4-dimensional Phase-contrast Magnetic Resonance Imaging
NCT04481542
In Vivo Evaluation of Growth and Risk of Rupture of Dilated Ascending Aorta Using 4D Cardiac Magnetic Resonance
NCT03172390
Coronary Computed Tomographic Angiography Combined With CT-FFR in Intermediate-Risk Chest Pain Patients.
NCT07140419
Prediction of Vulnerable Plaque Using Coronary CT Angiography and Computational Fluid Dynamic in Acute Coronary Syndrome
NCT04524117
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
This study is a retrospective descriptive study. The study will be conducted by Radiology Department, Second Affiliated Hospital, Zhejiang University.
Selection of patients:
The investigators included 57 patients who underwent enhanced contrast full-length aortic CTA scanning in the Radiology Department of Grade 3A General Hospital affiliated to a university from April to December 2019. Data of all participants following no apparent vascular tortuosity in CT diagnosis aged 18-70 years with contrast-enhanced computed tomography (CT) images of chest, abdomen, and pelvis from April to December in 2019 were analyzed. Participants whose images accompanied by vascular malformation, poor contrast enhancement, and history of aortic surgery were precluded.
Method General data of patients were collected through the hospital's electronic medical record system, including age, sex, height, weight, average body mass index ((Body Mass Index,BMI), history of surgery, etc.
The CTA examination of the participants' full aorta was performed with a 128-slice dual-energy CT scanner (Siemens, Germany), and the images were saved in the database. After screening the suitable participants, the images were transmitted to the CT workstation (Syngo VB10B Image processing system, Siemens, Germany). Multiplanar reconstruction, curvature plane reconstruction, and volume rendering were used for three-dimensional reconstruction. The diameters and lengths of blood vessels and the distances on the body surface were measured. The diameters of blood vessels included the diameter of the aorta at the edge of left subclavian artery, celiac trunk, lowest renal artery, and aortic bifurcation. The intravascular length included the lengths of zone I, zone II, zone III and the descending aorta. The length from the bilateral femoral artery puncture site to the midpoint of zone I and III, left subclavian artery, celiac trunk, lowest renal artery and aortic bifurcation, and the distances on the body surface included the distance from the bilateral femoral artery puncture site to the suprasternal notch, xiphoid process and umbilicus.
The results were described as mean ±standard deviation. SPSS20.0 software (IBM, USA) was used for analysis. Paired sample t-test was used to compare the differences between the left and right sides of the data. The difference was statistically significant when the P value was less than 0.05.
Data Management and Confidentiality Data Management: Using paper version for data management and storage. The person responsible for collecting paper version will input data in Excel database, summary paper and electronic versions for further statistical analysis and preservation.
Security measures: All records related to the identity of participants are to be confidential and not open to the public outside the scope of relevant laws or regulations.
Informed consent: This study is a retrospective study. Retrospective measurement of participants' previous aortic CTA imaging data does not infringe upon the interests of participants, so informed consent can be exempted.
Possible risks of participating in this study: disclosure of personal information.
Precautions against possible risks:
1. All the experimental data of the paper version and the electronic version shall be kept by the person in charge of the test data.
2. Close the measurement software in time after the end of the study, and confirm that the personal information has been cleared.
Intervention measures for possible risks:
If there is a disclosure of personal information, it is necessary to record the research report form and inform the person in charge of the research to intervene in time, and notify the Ethics Committee immediately.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
RETROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Characteristic of aortic length and body surface mark
The diameters and lengths of blood vessels and the distances on the body surface were measured by three-dimensional reconstruction using related Software on CT Workstation
CT workstation (Syngo Via VB10B, Siemens, Germany)
Multiplanar reconstruction, curvature plane reconstruction, and volume rendering were used for three-dimensional reconstruction to measure the diameters and lengths of blood vessels and the distances on the body surface
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
CT workstation (Syngo Via VB10B, Siemens, Germany)
Multiplanar reconstruction, curvature plane reconstruction, and volume rendering were used for three-dimensional reconstruction to measure the diameters and lengths of blood vessels and the distances on the body surface
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Aged 18-70 years old
* No obvious tortuosity diagnosed by CT
Exclusion Criteria
* Aortic aneurysm
* Severe aortic malformation
* Severe aortic plaque
* History of aortic operation.
18 Years
70 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Second Affiliated Hospital, School of Medicine, Zhejiang University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University
Hangzhou, Zhejiang, China
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
White JM, Cannon JW, Stannard A, Markov NP, Spencer JR, Rasmussen TE. Endovascular balloon occlusion of the aorta is superior to resuscitative thoracotomy with aortic clamping in a porcine model of hemorrhagic shock. Surgery. 2011 Sep;150(3):400-9. doi: 10.1016/j.surg.2011.06.010.
Stannard A, Eliason JL, Rasmussen TE. Resuscitative endovascular balloon occlusion of the aorta (REBOA) as an adjunct for hemorrhagic shock. J Trauma. 2011 Dec;71(6):1869-72. doi: 10.1097/TA.0b013e31823fe90c. No abstract available.
Linnebur M, Inaba K, Haltmeier T, Rasmussen TE, Smith J, Mendelsberg R, Grabo D, Demetriades D. Emergent non-image-guided resuscitative endovascular balloon occlusion of the aorta (REBOA) catheter placement: A cadaver-based study. J Trauma Acute Care Surg. 2016 Sep;81(3):453-7. doi: 10.1097/TA.0000000000001106.
Okada Y, Narumiya H, Ishi W, Iiduka R. Anatomical landmarks for safely implementing resuscitative balloon occlusion of the aorta (REBOA) in zone 1 without fluoroscopy. Scand J Trauma Resusc Emerg Med. 2017 Jul 3;25(1):63. doi: 10.1186/s13049-017-0411-z.
Eliason JL, Derstine BA, Horbal SR, Wang NC, Holcombe SA, Chiu CH, Ross BE, Bromwell B, Morrison J, Wang SC. Computed tomography correlation of skeletal landmarks and vascular anatomy in civilian adult trauma patients: Implications for resuscitative endovascular balloon occlusion of the aorta. J Trauma Acute Care Surg. 2019 Jul;87(1S Suppl 1):S138-S145. doi: 10.1097/TA.0000000000002247.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2019-333
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.