Isokinetic Performance After Cruciate-substituting Ultra-congruent and Posterior Stabilized Total Knee Arthroplasties
NCT ID: NCT04419311
Last Updated: 2021-03-16
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
66 participants
INTERVENTIONAL
2017-01-19
2018-03-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
A total of 65 patients scheduled to undergo TKA on for primary knee osteoarthritis were randomly assigned to either the UC (32 patients) or the PS group (33 patients). The Knee Society Score (KSS) and isokinetic performance results of each patient were recorded preoperatively and at postoperative 3, 6 and 12 months. The physiatrist performing isokinetic tests and patients were blinded to the study.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Kinematic Comparison of Vanguard XP and Vanguard CR Total Knee Arthroplasties
NCT02921594
A Prospective Randomized Study on Vanguard Cruciate Retaining Versus Vanguard High Flex Posterior Stabilized Total Knee System in the Early Range of Motion
NCT00763113
Performance of MOTO Medial® Unicompartmental Knee Arthroplasty
NCT03211663
Bilateral Total Knee Arthroplasty vs Unicompartment Arthroplasty Retrospective and Clinical Outcome Study
NCT02583113
Unicondylar Knee Arthroplasty Versus Total Knee Arthroplasty in Patients With Anteromedial Osteoarthritis of the Knee
NCT02430129
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
During the UC and PS operations, Vanguard® Complete Knee System prosthesis (Zimmer Biomet Inc., Warsaw, IN, USA) will be implanted using the same surgical technique in all patients. The Vanguard anterior-stabilized (AS) insert is a UC deep-dish design with a 10 mm prominent anterior lip and 5mm posterior lip. This bone-conserving design prevents anterior femoral subluxation because of the prominent anterior lip. The insert design allows it to be used with the Vanguard cruciate-retaining femoral component and the highly congruent articulating surface increases rotational stability. There is more contact area between the femoral component and the weight-bearing surface to decrease the shear stress between the femur and polyethylene insert.
A tourniquet will be inflated to pressure of 300 mmHg after spinal anesthesia. All operations will be performed with the same surgical technique by a single senior surgeon. Patellar surface arthroplasty will be performed in all the cases. Both femoral and tibial prostheses will be implanted with pressured bone cement. A suction drain will be placed inside the knee capsule. On the morning of the first day after surgery patients will be mobilized under the supervision of the physical therapist. All patients will undergo the same rehabilitation procedure during the outpatient period and will be examined by the same physiatrist at the regular 3, 6, and 12-month follow-up visits.
The primary outcome is isokinetic performance, measured as peak knee extensor and flexor torque values in Newton-meters, on the operated knee. Measurements wilil be done preoperatively and at 3, 6, and 12-month follow-up examinations under the supervision of the same physiatrist. At same time points, the Knee Society Score (KSS) will be evaluated as well. Isokinetic measurements will be performed using a Biodex System III Isokinetic Dynamometer, version 3.03 (Biodex Medical Inc., Shirley, NY, USA) by the same senior physiatrist. Patients will be positioned on the dynamometer with the hip in 90° in a sitting position for the knee flexion and extension measurements. Lateral movement of the knee will be prevented during full extension and flexion of the knee by a thigh strap on the operated leg. The physical therapist will help the patients to achieve proper positioning before each test. Concentric isokinetic knee flexion-extensions will be assessed at a preset velocity of 60º/sec, over a range of motion of 0º to 110º for both parameters. A fixed number of 10 flexion-extension repetitions will be completed by each patient. Instructions will be provided, and one trial repetition will then performed by all patients before the measurements were taken.
Sample size estimation will be performed using the extension peak torque as a primary effect variable. As there is no similar study with isokinetic measurements regarding this subject, a difference in mean values of 10 Nm and standard deviation of 12 Nm were assumed for each group. The group sample sizes of 31 and 31 achieved a power of 0.90 to detect a difference of 10 Nm between the two groups with estimated group standard deviations of 12 for each group and with a significance level (alpha) of 0.05 using a two-sided, two-sample test. Considering the loss to follow-up, two patients were added to each group. Thus, recruitment will end after 33 patients were assigned to either groups. All data will be calculated as mean and standard deviation. The Student's t-test will be used for statistical analysis of the patient data. Statistical calculations will be performed with SPSS 22.0 software (IBM SPSS Statistics for Windows, Version 22.0. Armonk, NY: IBM Corp.). A value of p\< 0.05 will be considered statistically significant.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Ultra-congruent insert group
Ultra-congruent inserts were used during total knee arthroplasty in patients randomized to this group.
Vanguard® Knee System
Posterior cruciate ligament retention versus sacrificing is one of the main debates in total knee arthroplasty (TKA) and retention or sacrificing depends on the individual preference of the surgeon during the surgery. Whenever the surgeon decides to sacrifice the posterior cruciate ligament (PCL), another controversial question arises regarding the tibial insert type. While the posterior cruciate ligament-stabilized (PS) insert is widely used as the tibial insert in PCL-sacrificing TKA, it has some disadvantages such as increased polyethylene wear, additional bone resection, breakage of the post and patellar clunk syndrome. The ultra-congruent (UC) insert was designed to prevent bone loss in particular, and the other mentioned disadvantages of the conventional PS insert. However, patients with postoperative hyperextension have been seen to be associated with inferior clinical outcomes and knees become gradually more extended until two years after TKA using the UC insert.
Posterior cruciate ligament-stabilized insert
Posterior cruciate ligament-stabilized inserts were used during total knee arthroplasty in patients randomized to this group.
Vanguard® Knee System
Posterior cruciate ligament retention versus sacrificing is one of the main debates in total knee arthroplasty (TKA) and retention or sacrificing depends on the individual preference of the surgeon during the surgery. Whenever the surgeon decides to sacrifice the posterior cruciate ligament (PCL), another controversial question arises regarding the tibial insert type. While the posterior cruciate ligament-stabilized (PS) insert is widely used as the tibial insert in PCL-sacrificing TKA, it has some disadvantages such as increased polyethylene wear, additional bone resection, breakage of the post and patellar clunk syndrome. The ultra-congruent (UC) insert was designed to prevent bone loss in particular, and the other mentioned disadvantages of the conventional PS insert. However, patients with postoperative hyperextension have been seen to be associated with inferior clinical outcomes and knees become gradually more extended until two years after TKA using the UC insert.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Vanguard® Knee System
Posterior cruciate ligament retention versus sacrificing is one of the main debates in total knee arthroplasty (TKA) and retention or sacrificing depends on the individual preference of the surgeon during the surgery. Whenever the surgeon decides to sacrifice the posterior cruciate ligament (PCL), another controversial question arises regarding the tibial insert type. While the posterior cruciate ligament-stabilized (PS) insert is widely used as the tibial insert in PCL-sacrificing TKA, it has some disadvantages such as increased polyethylene wear, additional bone resection, breakage of the post and patellar clunk syndrome. The ultra-congruent (UC) insert was designed to prevent bone loss in particular, and the other mentioned disadvantages of the conventional PS insert. However, patients with postoperative hyperextension have been seen to be associated with inferior clinical outcomes and knees become gradually more extended until two years after TKA using the UC insert.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Scheduled to undergo unilateral TKA on for primary knee osteoarthritis
Exclusion Criteria
* Previous knee surgery
* Neuromuscular diseases
* Bilateral TKA
* Insufficiency of collateral ligaments
55 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Aksaray University Training and Research Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Erdem A Sezgin
Co-Principal Investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Deniz Çankaya, MD
Role: PRINCIPAL_INVESTIGATOR
Aksaray University Training and Research Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Aksaray University Training and Research Hospital
Aksaray, , Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
1585/2017
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.