BIOPSY SCANNER LLTECH© Technology for Diagnosis of Breast Cancer

NCT ID: NCT04292821

Last Updated: 2020-05-27

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

204 participants

Study Classification

OBSERVATIONAL

Study Start Date

2020-04-28

Study Completion Date

2021-09-15

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Breast cancer is a frequent pathology and the speed of initial diagnosis makes it possible to improve the course of care and to reduce the anxiety of the patients. For a complete assessment, several biopsies may be necessary, including lymph node biopsies. Once the histological sample has been taken, a preparation is necessary (time consuming technician) then a reading by a pathologist requiring at least 48-72h. Cytology allows immediate diagnosis, but it requires the presence of a pathologist in the collection room. Finally, some biopsies can be non-contributory (if there is not enough tissue removed) and require new samples. A tool allowing immediate control of the tissue and an initial diagnosis without mobilizing the pathologist (who will make the result complete with immunohistochemistry) would make it possible to anticipate the next course of care and facilitate treatment. The BIOPSY SCANNER LLTECH © technology would allow images on fresh unprepared tissue to obtain images allowing immediate diagnosis by a non-pathologist, the same tissue could then be technical for a complete analysis by the pathologist.

The investigators propose a study evaluating the diagnostic capacities by non pathologists from images obtained by the BIOPSY SCANNER LLTECH © technology on breast and lymph node biopsies. Based on this study, an atlas on breast lesions could be created to allow a broader evaluation of this technology in daily practice in diagnostic of breast pathology.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

In France, 59,000 new cases of breast cancer are diagnosed per year, but with systematic screening, more than 400,000 women will be biopsied each year. Less than 50% of women in France respond to organized screening and one of the reasons put forward is in particular the anxiety linked to waiting for the result of the biopsy if it turns out to be necessary.The BIOPSY SCANNER LLTECH © technology would allow images on fresh unprepared tissue to obtain images allowing immediate diagnosis by a non-pathologist (Annex 2: description of the manufacturer), the same tissue could then be technically analyzed for a complete analysis pathologic.

The BIOPSY SCANNER LLTECH © is an optical imaging device for the microscopic evaluation of deep tissue samples. It enables rapid imaging of samples on a cellular scale, in a non-invasive and non-destructive manner, and to reveal their microarchitecture and cellular organization.

The Biopsy Scanner uses the patented technique of full field white light interferometry. This technique is considered to be the equivalent of optical resolution ultrasound (≈ 1 μm) in 3 directions. A sample placed in the system is illuminated by an inconsistent light source.

The light reflected by the sample is collected by the interferometer and interferes with the light reflected by a reference mirror. This interference signal is recorded by a camera. The interferometric technique and the coherence properties of the light source make it possible to select the signal which comes from a limited volume in the depth of the sample. This property of the system is called optical sectioning and ensures good axial imaging resolution (1 μm). The transverse resolution is good (1.5 μm) thanks to the integration of microscope objectives in the interferometer.

Currently, it is necessary for an immediate diagnosis of breast cancer to have a second expert cytologist doctor (it is a difficult learning technique) in the radiologist's room to check that the tissue removed is sufficient. In addition, a second sample is necessary to obtain a complete histology. The BIOPSY SCANNER LLTECH © technology could allow patients to be informed more quickly while avoiding mobilizing on-site expertise and taking 2 samples.The investigators hypothesize that the BIOPSY SCANNER LLTECH © technique will allow the radiologist to provide immediately after the breast or lymph node biopsy, on fresh unprepared tissue, a positive or negative diagnosis of cancer, with sufficient diagnostic performance to consider its generalization.

The study will also allow us to see whether a learning curve is necessary and to assess its duration. It should be noted that there is no reason to think a priori that the sensitivities / specificities will be different depending on the type of biopsy (breast or lymph node) which will therefore be analyzed in the same group in the main analysis.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Breast Cancer

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Patients consulting for breast lesion Bi Rads 4 or 5

Patients consulting for breast lesion Bi Rads 4 or 5

No interventions assigned to this group

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients over 18 years old requiring a breast biopsy for an birads 4 or 5 nodular radiological lesion or lymph node for a lymph node judged to be radiologically suspect (cortex thickened by more than 3 mm)

Exclusion Criteria

* Patients under 18
Minimum Eligible Age

18 Years

Eligible Sex

FEMALE

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Assistance Publique - Hôpitaux de Paris

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Catherine UZAN, Md PhD

Role: PRINCIPAL_INVESTIGATOR

Pitié-Salpêtrière Hospital (AP-HP)

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Hôpital de la Pitié Salpêtrière

Paris, , France

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

France

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Catherine UZAN, Md PhD

Role: CONTACT

01 42 17 81 14

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Catherine UZAN, Md PhD

Role: primary

01 42 17 81 14

Geoffroy CANLORBE, Md PhD

Role: backup

01 42 17 81 29

References

Explore related publications, articles, or registry entries linked to this study.

Simon A, Badachi Y, Ropers J, Laurent I, Dong L, Da Maia E, Bourcier A, Canlorbe G, Uzan C. Value of high-resolution full-field optical coherence tomography and dynamic cell imaging for one-stop rapid diagnosis breast clinic. Cancer Med. 2023 Oct;12(19):19500-19511. doi: 10.1002/cam4.6560. Epub 2023 Sep 29.

Reference Type DERIVED
PMID: 37772663 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

APHP191059

Identifier Type: -

Identifier Source: org_study_id

More Related Trials