Human Factors Validation Testing for the Peripal System; a Manual Connection Assist Device for Peritoneal Dialysis Devices
NCT ID: NCT04292210
Last Updated: 2020-03-03
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
24 participants
INTERVENTIONAL
2018-02-19
2018-04-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Assisted Peritoneal Dialysis: A Feasibility Study
NCT04319185
Randomized Controlled Trial on 3D Printed Assistive Device for Continuous Ambulatory Peritoneal Dialysis
NCT05521425
Evaluation of Biocompatibility and Performances of 4 Dialyzers in Different Mode Treatments
NCT03262272
Mobilising Lower Limb Fluid for Hemodynamic Stability in Haemodialysis
NCT02450474
Interactive Videoconferencing in the Provision of Remote Peritoneal Dialysis
NCT02428803
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
As part of the CE marking authorization, the connection device has been evaluated for safety and ease of use in a study at University Hospitals Birmingham NHS Foundation Trust involving 24 patients and carers.
The evaluated device is designed to assist peritoneal dialysis patients performing their daily dialysis treatment either for APD or for CAPD. The device facilitates the connection and disconnection of the dialysis line to the PD catheter transfer set. The connections are performed inside the device in a protected area, and the patient does not need to touch the transfer set or the dialysis line while they are unprotected. In addition, the breaking of the dialysis line frangible and the clamping of the dialysis line are replaced by pushing a button.
The operating procedure of the device consists of multiple tasks including preparing and loading the transfer set and dialysis line into the device, performing the handling steps related to the PD therapy with the device and finally unloading the used material from the device. Each task comprises several handling steps. During the study, the operating procedure with the device was simulated and the subjects were connected to a dummy catheter, which was attached to an apron.
This study recruited established PD patients and carers involved in the delivery of PD. Carers included healthcare professionals and lay carers.
The study design was divided into three one hour long parts. Firstly, a training session introduced the operation of the device. Secondly, a break of one hour allowed relaxation and recovery. Thirdly, a test was carried out to determine whether the subject could use the device independently with the aid of a quick start guide and the device manual.
The training consisted of two cycles in which the moderator guided the subject and three cycles in which the subject guided the moderator through the complete handling of the device. After the break, the subjects were asked to carry out a complete handling cycle themselves. Subjects could use the quick start guide and the device manual as help. After the unsupported handling cycle, subjects were asked to complete the NASA Task Load Index (N-TLX) questionnaire. In the meantime, the moderator left the room to obtain information on observed use errors. In a final semi-structured interview, the subjects were asked about the reasons for the observed use errors.
For each subject, one moderator and one observer were involved in the study. The moderator was the interface between the subject and the device both in training and in testing. This person was employed by an external agency to avoid any influence on the subject. The observer saw the handling with the help of a live feed from a separate room. He evaluated the handling steps in the categories of "safe use" and "use error" according to IEC 62366-1. For each use error, the observer described the observed situation from his point of view. In addition to evaluating the effectiveness of the task performance, the subjects were interviewed in a semi structured way. Here the observations of technique errors were discussed with the subjects in order to identify the specific causes. In this interview, the subjects were also asked for their feedback on the general ease of use of the device.
In addition, the subjects were asked about the task load in six different dimensions in the standardized N-TLX. Task load is a hypothetical construct that represents the cost incurred by a human operator to achieve a particular level of performance. The dimensions of the N-TLX are mental, physical and temporal demands as well as performance, effort and frustration in the task. Each dimension is evaluated on a 20-point scale. This scale is then transferred to the task load index, which is a scale between 0 and 100 points. To classify the results of the N-TLX, Eitrheim and Fernandes (2016) state "Workload levels below 50 were perceived as acceptable."
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
As part of the CE marking authorization, the connection device has been evaluated for safety and ease of use in a study at University Hospitals Birmingham NHS Foundation Trust involving 24 patients and carers.
OTHER
NONE
For each subject, one moderator and one observer were involved in the study. The moderator was the interface between the subject and the device both in training and in testing. This person was employed by an external agency to avoid any influence on the subject.
The observer saw the handling with the help of a live feed from a separate room. He evaluated the handling steps in the categories of "safe use" and "use error" according to IEC 62366-1 (2015). For each use error, the observer described the observed situation from his point of view.
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
CAPD handling
A connecting device simplifying the steps during a cycle of Peritoneal dialysis. Instead of directly doing a manual connection and manually breaking a frangible, the device assist in connecting and breaking the frangible.
This study was done demonstrating a continuous ambulatory peritoneal dialysis (CAPD)
Perisafe
A medical device simplifying the connection of tubing as well as breaking of the frangible which is done in a sterile environment with the help of levers and buttons.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Perisafe
A medical device simplifying the connection of tubing as well as breaking of the frangible which is done in a sterile environment with the help of levers and buttons.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Swiss Federal Institute of Technology
OTHER
University Hospital Birmingham NHS Foundation Trust
OTHER
Peripal AG
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Lukas Foggensteiner, MD, PhD
Role: STUDY_CHAIR
National Health Service, United Kingdom
Mirko Meboldt, PhD
Role: STUDY_CHAIR
ETH
Martin Dubach
Role: STUDY_CHAIR
Peripal AG
Stephan Hess
Role: PRINCIPAL_INVESTIGATOR
ETH
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
NIHR Trauma Management MedTech Co-operative
Birmingham, , United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Related Links
Access external resources that provide additional context or updates about the study.
Evaluating Patient Safety and Ease of use of a Novel Connection-Assist Device for Peritoneal Dialysis
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IRAS ID :235715
Identifier Type: -
Identifier Source: org_study_id
More Related Trials