Mobile Biosensor for Measuring Vital Signs in Healthcare and Home Settings
NCT ID: NCT04233827
Last Updated: 2025-06-19
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
361 participants
OBSERVATIONAL
2016-10-20
2022-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Non-contact Blood Pressure and SpO2 Measurement Based on Image Sensor
NCT06204822
SpO2 System Accuracy Testing With Different Sensors
NCT01613222
A Clinical Trial to Verify the Accuracy of Seers Technology's Pulse Oximeter (mobiCARE +Pulse, MP100W) in Healthy Volunteers
NCT05895682
RDS MultiSenseĀ® SpO2 Validation Study
NCT05359328
Clinical Trial Testing the BioSerenity Pulse Oximeter (EOXY) Efficacy, Performance and Safety in Healthy Volunteer
NCT03614416
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
For Phase 1, up to 800 subjects will be recruited (700 adults and up to 100 adolescents). 250 subjects (200 adults and up to 50 adolescents) will participate in phase 1a and 550 subjects (500 adults and up to 50 adolescents) will participate in phase 1b. An additional group of 30 adult subjects will be recruited from outpatient clinics for participation in phase 2.
Phase 1a:
Two identical copies of the device will be tested during the first part of phase 1 with a total of 125 subjects (100 adults and up to 25 adolescents). Each prototype version will be tested on up to 125 subjects (100 adults and 25 adolescents) and compared to readings obtained by Welch-Allyn Spot Vital Signs monitor. Data will be obtained on the usability and accuracy of the measurements with each initial prototype. Measurement particularly of SpO2 depends on accurate finger position. Current SpO2 monitors encase the finger and immobilize it in order to obtain an accurate measurement. Maxim Integrated, in collaboration with DD Studios, Carlsbad CA, and Specialists in Global Health, Encinitas CA, have developed prototypes, which will be tested to inform design flaws in future prototypes.
Phase 1b:
Based on the results from phase 1a, one of the prototypes will be selected for further testing (the one with the least within-instrument variation). During Phase 1b, vital sign readings will be collected with the selected Maxim biosensor prototype and one of the Welch-Allyn Spot Vital Signs monitor simultaneously. The subjects will be recruited from both outpatient and hospital settings for accuracy and usability. A total of 550 subjects (500 adults and 50 adolescents) will be recruited for this part of phase 1.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Subjects must be willing to use the mobile device and answer questions regarding their experience.
Exclusion Criteria
13 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of California, San Diego
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Sara H. Browne, MD, MPH
Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Sara H Browne, MD MPH
Role: PRINCIPAL_INVESTIGATOR
UC San Diego
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
UCSD AntiViral Research Center
San Diego, California, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Browne SH, Bernstein M, Pan SC, Gonzalez Garcia J, Easson CA, Huang CC, Vaida F. Smartphone Biosensor With App Meets FDA/ISO Standards for Clinical Pulse Oximetry and Can Be Reliably Used by a Wide Range of Patients. Chest. 2021 Feb;159(2):724-732. doi: 10.1016/j.chest.2020.08.2104. Epub 2020 Sep 11.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
161573
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.