Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
48 participants
INTERVENTIONAL
2018-01-20
2019-05-14
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
This study was conducted on 48 students selected from Aydın Adnan Menderes University. Four main groups were determined according to the results of the application acceptance survey. Blood pressure, electrocardiogram, breath rate, haemoglobin oxygen saturation and bioelectrical impedance analysis were measured before consuming the drinks. After consuming the drinks, measurements were repeated at 30 minutes and 60 minutes. In addition to this, Participant's Situation Anxiety Scale was applied.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effects of Chronic Energy Drink Consumption on Cardiometabolic Endpoints
NCT03840863
Health Effect of Energy Drink Consumption
NCT04961086
The Effect of Energy Drink Ingredients on Cardiovascular Function in Men and Women 18-39 Years Old
NCT04149717
Cardiovascular Effects of Energy Drinks in Healthy Adults
NCT01940822
Impact of Energy Drinks on Cardiovascular Endpoints
NCT01329679
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Materials and methods Participants Forty eight participants (16 female, 32 male) aged 18-24 were selected from the students which are in the first year of various faculties of Aydın Adnan Menderes University. The individuals were identified by collecting the age, weight, height, BMI, caffeine and energy drink consumption habit information by applicant acceptance questionnaire. According to the results of applicant acceptance questionnaire, those with a body mass index greater than 30 kg/m2, a systemic disease, current alcoholism and smokers were not included in the study. Also, the participants who has previous adverse reactions to energy drinks were excluded to prevent undesired reactions associated with this condition. Based on the applicant acceptance questionnaire 12 subjects were low-habitual caffeine consumers with an estimated daily intake of approximately 130 mg caffeine and named as energy drink 2 (ED2) group, 12 subjects were high-habitual caffeine consumers with an estimated daily intake of approximately more than 200 mg caffeine and named as energy drink 3 (ED3) group, while 24 subjects were caffeine naive (energy drink 1 (ED1) (n=12) and Control (n=12)) . This study conforms to the Declaration of Helsinki and was approved by the Institutional Medical Ethics Committee of Adnan Menderes University (Protocol number: 2017/1211).
Experimental protocol All experiments were performed in a quiet and isolated room from external factors with room temperature of about 20°C and relative humidity between %40 and 60. All participants were advised to avoid alcohol and caffeine containing foods for at least 72 h prior to the test and to come with an overnight (12 h) fasting.
Blood pressure, electrocardiogram, breath rate, haemoglobin oxygen saturation (HOS) and BIA measurements were performed from the participants before the consumption of drinks. After the measurements ED1, ED2 and ED3 groups consumed 473 ml of Red Bull energy drink containing 151.36 mg caffeine and control group consumed the same amount of water within 5 minutes. The measurements were performed again in 30 minutes and 60 minutes. Also, state-trait anxiety inventory test (STAI) was used to assess the physiological stress of the participants.
Blood Pressure Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured indirectly by using a stethoscope (Littman Classic II, Saint Paul, USA) and aneroid sphygmomanometer (Welch Allyn Tycos, New York, USA) on each participant left arm in sitting position.
Electrocardiography (ECG) After a 5 min resting in the sitting position ECG recordings were obtained from all the individuals for 5 min in rest. Disposable Ag-AgCl electrodes were placed following the Einthoven triangle configuration. ECG measurement was performed with sampling frequency 200 Hz using ECG100C unit and BIOPAC Acqknowledge acquisition software (Biopac System Inc., Santa Barbara, CA) connected to a personal computer. PR interval, QRS complex and QTc interval values were determined from ECG recordings of the participants. QTc was calculated by Bazett's formula (QTc=QT/RR). Their normal range values are 120-200 ms, normal\<140 ms and normal \< 400 ms, respectively.
For acquiring the heart rate variability (HRV) time series, Pan and Thompkins algorithm was used. R peaks were detected and R-R intervals are defined. The time duration between two consecutive R peaks is termed as RR interval (tRR). The sample size of the HRV time series is 400. The heart rate (HR) is determined as:
HR=60/t\_RR State-trait Anxiety Inventory (STAI) It is a test developed to determine the psychological stress during the study. STAI is defined as state and trait anxiety scale. This test is composed of two parts (40 questions). State Anxiety scale consisting of the first 20 questions was used to obtain information about the acute anxiety state of participants at the time of the study. Each question is evaluated using an ordinal scale (not at all=1, somewhat=2, moderately=3, very much=4). The total score is obtained as the sum of each answer value and gives information about the anxiety state of the participant. A total score of 50 or more is considered as positive pathological anxiety.
Haemoglobin Oxygen Saturation (HOS) HOS was measured by using a fingertip pulse oximeter on the second left finger for 1 min.
Breath Rate Breath rate measurements were taken from the participants by counting the breaths for one minute with the use of a stethoscope (Littman Classic II, Saint Paul, USA).
Bioelectrical Impedance Analysis (BIA) BIA measurements were taken by using In Body 720 before the consumption of the drinks and at 60th minute after the consumption. Each participant was asked to stand on the body composition analyzer after undressing their clothes. In Body 720 has an eight-point tactile electrode system that separately measures the impedance of the arms, trunk and legs. It measures directly the amount of the intracellular water (ICW), extracellular water (ECW), body fat percentage (PBF), body mass index (BMI) and body metabolism rate (BMR).
Statistical analysis Statistical analysis of the data was performed by using SPSS Statistics for Windows, Version 14.0. (SPSS Inc., Chicago, Illinois, USA). For comparing the groups first of all Shapiro-Wilk (SW) normality test was applied to determine the normality of the distribution. If the result of (SW) normality test was bigger than 0.05 the data were normally distributed and were analysed by using one-way analysis of variance (ANOVA) with Bonferroni post-test but if the result was less than 0.05 the data were not normally distributed and were analysed by using Kruskal-Wallis non-parametric test. Repeated ANOVA test was used for the comparison of different measurement time data of the same group. Descriptive statistics were presented as mean ± standard error of the mean (SEM). A p-value of less than 0.05 was considered to indicate statistical significance.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
DIAGNOSTIC
TRIPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Energy Drink 1
The participants in this group are caffeine naive and consumed 473 ml Red Bull Energy Drink
Red Bull Energy Drink
473 ml Reb Bull Energy Drink
Energy Drink 2
The participants in this group were low-habitual caffeine consumers with an estimated daily intake of approximately 130 mg caffeine and consumed 473 ml Red Bull Energy Drink
Red Bull Energy Drink
473 ml Reb Bull Energy Drink
Energy Drink 3
The participants in this group were low-habitual caffeine consumers with an estimated daily intake of approximately more than 200 mg caffeine and consumed 473 ml Red Bull Energy Drink
Red Bull Energy Drink
473 ml Reb Bull Energy Drink
Control
The participants in this group are caffeine naive and consumed 473 ml water
Water
473 ml Water
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Red Bull Energy Drink
473 ml Reb Bull Energy Drink
Water
473 ml Water
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* a systemic disease
* current alcoholism
* smokers
* the participants who has previous adverse reactions to energy drinks
18 Years
24 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Aydin Adnan Menderes University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Mehmet Dincer Bilgin
Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Serife G Caliskan, PhD.
Role: STUDY_DIRECTOR
Aydin Adnan Menderes University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Aydin Adnan Menderes University
Aydin, , Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Caliskan SG, Kilic MA, Bilgin MD. Acute effects of energy drink on hemodynamic and electrophysiologic parameters in habitual and non-habitual caffeine consumers. Clin Nutr ESPEN. 2021 Apr;42:333-338. doi: 10.1016/j.clnesp.2021.01.011. Epub 2021 Feb 4.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2017/1211
Identifier Type: -
Identifier Source: org_study_id
More Related Trials