Vitamin E Polyethylene in Semented Cups

NCT ID: NCT04126421

Last Updated: 2020-01-07

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

68 participants

Study Classification

INTERVENTIONAL

Study Start Date

2011-04-01

Study Completion Date

2019-06-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

A prospective randomized controlled study evaluating the wear and migration of cemented acetabular sockets with third generation highly cross-linked vitamin E infused polyethylene and second generation highly crosslinked UHMWPE using Radiostereometric Analysis (RSA).

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Background Reducing the rate of polyethylene (PE) wear in acetabular sockets and thereby increasing the lifespan of Total Hip Arthroplasty (THA) has been a major concern in the orthopaedic community for decades. Wear of PE and osteolysis followed by late aseptic loosening of the prosthesis is the main reason for revision surgery after THA in Norway.

During 2008 in Norway 805 out of a total of 1114 revised THA were subjugated to surgery due to aseptic loosening or osteolysis without loosening. The DRG (Diagnose Related Grouping) weight is 5.49 for secondary THA and every DRG point has a value of 33.647 NOK adding up to a direct total cost for revision after aseptic loosening of approximately 27 million USD.

Caput prosthesis with a diameter of 32mm or more has the major advantage to increase the Range of Motion (ROM) and to reduce the risk of dislocation of the hip but, the larger the caput prosthesis the more adhesive wear can be expected. This and the relative failure of metal on PE gave the incentive to develop and take into clinical practise bearings with increased resilience to wear. Today, there exists a wide range of options with a substantially lower rate of volumetric wear compared to conventional PE. The biological and immunological in vivo response to wear particles is very complicated and only partially understood. It is clear that host response to wear particles and the corrosion products play a major role in osteolysis around the prosthesis. For metal-on-metal (MoM) bearings the volumetric wear is a magnitude less but the number of particle debris is massively increased. MoM also have the problem with possible teratogen effect and allergy or hypersensitivity side effects. Ceramic on ceramic (cer-cer) has the lowest wear rate of any artificial articulations, but it is still possible to detect biologically active debris particles. Cer-cer also has other challenges including fracture of prosthesis, squeaking hip, narrow margins for placing components and cost.

Polyethylene is a thermoplastic polymer consisting of long chains of the monomer ethylene (C2H4). The mechanical properties of PE depend on variables such as the extent and type of branching and the crystal structure etc.

To improve the wear resistance of the PE an increase in the cross-linking between the chains of polyethylene can be achieved by exposing it to high-energy irradiation. The irradiation also increases the unpaired free electrons (free radicals). Free radicals can react with oxygen and start a chain reaction causing an oxidative degradation of the polyethylene and consequently cause increased wear. 1st generation HXLPE sockets have reduced the mid term incidence of particle-induced osteolysis but retrieved failed first-generation HXLPE sockets have shown surface cracking and signs of in vivo oxidative degradation.

In order to enhance the resistance to mechanical fatigue and reduce oxidative potential 2nd generation HXLPE was developed. To reduce the oxidative potential the polyethylene can be remelted or annealed. Remelting aggravates the mechanical properties of the polyethylene and after annealing there are still remaining free radicals capable of oxidation in vivo. By binding to unpaired free electrons Vitamin E is a scavenger of free radicals. Vitamin E is hydrophobic and can thereby be infused into polyethylene. 3rd generation HXLPE is manufactured below the melting temperature to maintain its mechanical properties and contains Vitamin E to stabilize free radicals. Uncemented Acetabular HXLPE sockets have been shown to have substantially reduced volumetric wear and excellent clinical mid-term results with this type of PE. In Scandinavia the majority of sockets are cemented. The different principles of biological or mechanical stability affects the properties of the socket typically different E-module and the surrounding interface between implant and bone. Conventional PE cemented cups have performed better with less aseptic loosening than uncemented cups. However, as the mechanical properties are changed in highly cross-linked Polyethylene cups, it is not clear whether the higher elasticity of the bone-cement-polyethylene compound might lead to fractures of the more brittle polyethylene. It is therefore not possible to extrapolate clinical results and wear rates from uncemented cups to cemented ones.

Placement of the cup is a crucial parameter for wear and cup survival. Malchau et al. has shown that even high volume surgeons achieve suboptimal placement in 40% of cases. This may depend on patient positioning perioperative, surgical instruments or technique. It is not known whether the surgeon's subjective operative technique directly corresponds to the postoperative evaluation of the cups position. However, adequate cup positioning is crucial in the evaluation of wear. CT is the best method to judge cup position postoperatively and detect osteolysis in the long time perspective.

To the investigators knowledge no randomized controlled study of cemented 3rd generation HXLPE cups utilizing RSA has been conducted.

Hypothesis There is a mid term in vivo reduction of volumetric polyethylene wear with cemented acetabular socket 3rd generation E1™ HXLPE compared with 2nd generation HXLPE.

Material: 70 eligible patients will be included following written informed consent. The participants will be randomized by the envelope method to either E1™ or Marathon™ cemented acetabular socket. The surgery will be performed at the hospitals in Vestre Viken HF and Oslo University hospital HF, Ullevål ortopeden.

Implant The investigators will use two different cemented all PE acetabular sockets;

1. MarathonTM is a 1st generation HXLPE. The polyethylene is cross-linked with 5 Mrad that corresponds to a semi cross-linked PE.
2. The E1™ cemented is an all PE Vitamin E stabilized 3rd generation highly crosslinked UHMWPE. In vitro tests have shown a 99 % decreased volumetric wear rate comparing E1™ with ArComXL™ HXLPE, (highly crosslinked polyethylene) under high contact stress and a 95% reduction in wear rate comparing E1™ with ArCom™ under high contact area stress. Wear particle morphology of E1™ is similar to that of the ArCom™ material.

Collared Corail™ (De Puy, Warsaw, Indiana, USA) uncemented femoral prosthesis is a titanium tapered implant fully coated with 150 micron hydroxyapatite with over 95% survival after 15 years. The caput prosthesis used is the Cobalt Chrome 32 mm Articul/EZE™ (De Puy, Warsaw, Indiana, USA) Refobacin ™ (Biomet Europe, Berlin, Germany) Bone Cement R is a high viscosity, x-ray positive bone cement. A sachet of 40 g Refobacin® Bone Cement R contains 0.5 g gentamicin.

Surgical technique The patient is operated in the position after surgeon's preference and under spinal anaesthesia. Accordingly the approach is after surgeon's preference. When posterolateral approach is chosen a repair of the capsule and the external rotators should be performed. Peroperatively a total of 6 1,0mm tantalum beads are implanted in the perimeter of the socket and 7 beads in the acetabulum. The acetabular socket is positioned as close to 45◦ abduction and 30◦ anteversion as possible.

The surgeon will postoperative directly grade cup position subjectively as anteverted, neutral, retroverted, proximalized, distalized.

Postoperative training Postoperatively the patient is mobilized with full weight bearing from day one.

Radiological analyses Conventional x-ray of pelvis, anterioposterior and lateral projections of hip preoperatively, postoperatively and at 24 (60, 120) months RSA (Radiostereometric analysis) postoperatively, 3, 12, 24 (60, 120) months, the RSA will be analysed at Ullevål University Hospital

Clinical Control Harris Hip Score, EQ-5D and WOMAC will be filled out preoperatively and at 2, 5 and 10 years.

Analysis of data RSA analysis will be performed at the Centre of Implant and Radiostereometric Research Oslo (CIRRO).

The study analysis is conducted under the guidance of CIRRO.

Storage of data Data will be collected and stored at the server for research at Oslo University Hospital. All data is stored anonymously. Each patient receives a study ID. The randomisation key and identity is stored separately.

Statistics Penetration of more than 0,1 mm annually in polyethylene articulations indicates a wear rate that will lead to future osteolysis1.

Scientific value Firstly, if recently developed manufacturing techniques of polyethylene can be shown to decrease the wear rate in vivo, and otherwise have a good clinical and radiological outcome, we have the reason to believe we have the possibility of significantly reducing the revision rate after THA.

Secondly, new implants should thoroughly be investigated and documented before widespread use. This could save many patients from possible disastrous failures as the past has taught us (Boneloc, Carbon compressed Poly).

Safety for the patient. The investigators will follow the normal routines for THA pre, per and postoperatively. Standardized routines in regards to infection and thrombosis prophylaxis following the recommendations from the Norwegian national board of orthopaedics will be followed. Implantation of Tantalum beads has been shown to have negligible side effects.

The E1TM and Marathon PE is clinically tested in uncemented THA, the other components of the prosthesis has more than 10 years clinical and RSA documentation.

Biomet will cover expenses including:

Extra cost of purchasing and storing prosthesis compared with standard prosthesis. Biomet or Stryker has no copy right or any other form of ownership to the result of this study.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Total Hip Arthroplasty (THA)

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Randomized controlled trial (RCT). Randomized to either E1 semented cup or Marathon semented cup in total hip arthroplasty (THA).
Primary Study Purpose

TREATMENT

Blinding Strategy

DOUBLE

Participants Caregivers

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

E1 Vitamin E infused HXLPE

E1 Vitamin E infused highly cross-linked polyethylene (HXLPE)

Group Type ACTIVE_COMPARATOR

Prosthesis component (acetabular cup) E1 cup

Intervention Type DEVICE

Semented acetabuar cup With E1 cup

Marathon HXLPE

Marathon highly cross-linked polyethylene (HXLPE)

Group Type ACTIVE_COMPARATOR

Prosthesis component (acetabular cup) Marathon cup

Intervention Type DEVICE

Semented acetabuar cup With Marathon cup

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Prosthesis component (acetabular cup) E1 cup

Semented acetabuar cup With E1 cup

Intervention Type DEVICE

Prosthesis component (acetabular cup) Marathon cup

Semented acetabuar cup With Marathon cup

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

E1 cup Marathon cup

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* patients under the age of 75 with primary or secondary arthrosis scheduled for total hip arthroplasty.

Exclusion Criteria

* a major anatomical deviation, immunosuppressive medication or a significant systemic disease.
Maximum Eligible Age

74 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Oslo

OTHER

Sponsor Role collaborator

Oslo University Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Peder Svenkerud Thoen

MD, Consultant Orthopedic Surgery

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Stephan M Röhrl, PhD, MD

Role: STUDY_CHAIR

Division of Orthopedic Surgery, Oslo University Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Division of Orthopedic Surgery, Oslo Univsersity Hospital

Oslo, , Norway

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Norway

References

Explore related publications, articles, or registry entries linked to this study.

Digas G, Karrholm J, Thanner J, Malchau H, Herberts P. The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop Relat Res. 2004 Dec;(429):6-16.

Reference Type BACKGROUND
PMID: 15577460 (View on PubMed)

Kjærsgaard-Andersen 2010 Orthopaedics today

Reference Type BACKGROUND

The Norwegian Arthroplasty Register, 2009

Reference Type BACKGROUND

Garcia-Cimbrelo E, Munuera L. Early and late loosening of the acetabular cup after low-friction arthroplasty. J Bone Joint Surg Am. 1992 Sep;74(8):1119-29.

Reference Type BACKGROUND
PMID: 1400540 (View on PubMed)

Barrack RL, Folgueras A, Munn B, Tvetden D, Sharkey P. Pelvic lysis and polyethylene wear at 5-8 years in an uncemented total hip. Clin Orthop Relat Res. 1997 Feb;(335):211-7.

Reference Type BACKGROUND
PMID: 9020220 (View on PubMed)

Tarasevicius S, Robertsson O, Kesteris U, Kalesinskas RJ, Wingstrand H. Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty: a sonographic and radiographic study of 39 patients. Acta Orthop. 2008 Aug;79(4):489-93. doi: 10.1080/17453670710015472.

Reference Type BACKGROUND
PMID: 18766481 (View on PubMed)

Harris WH, Muratoglu OK. A review of current cross-linked polyethylenes used in total joint arthroplasty. Clin Orthop Relat Res. 2005 Jan;(430):46-52. doi: 10.1097/01.blo.0000152603.58384.e9.

Reference Type BACKGROUND
PMID: 15662303 (View on PubMed)

Jacobs JJ, Roebuck KA, Archibeck M, Hallab NJ, Glant TT. Osteolysis: basic science. Clin Orthop Relat Res. 2001 Dec;(393):71-7. doi: 10.1097/00003086-200112000-00008.

Reference Type BACKGROUND
PMID: 11764373 (View on PubMed)

Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res. 1998 Oct;42(1):103-11. doi: 10.1002/(sici)1097-4636(199810)42:13.0.co;2-m.

Reference Type BACKGROUND
PMID: 9740012 (View on PubMed)

Campbell DG, Field JR, Callary SA. Second-generation highly cross-linked X3 polyethylene wear: a preliminary radiostereometric analysis study. Clin Orthop Relat Res. 2010 Oct;468(10):2704-9. doi: 10.1007/s11999-010-1259-y. Epub 2010 Feb 12.

Reference Type BACKGROUND
PMID: 20151231 (View on PubMed)

Ries MD, Pruitt L. Effect of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene. Clin Orthop Relat Res. 2005 Nov;440:149-56. doi: 10.1097/01.blo.0000185310.59202.e5.

Reference Type BACKGROUND
PMID: 16239799 (View on PubMed)

Bitsch RG, Loidolt T, Heisel C, Ball S, Schmalzried TP. Reduction of osteolysis with use of Marathon cross-linked polyethylene. A concise follow-up, at a minimum of five years, of a previous report. J Bone Joint Surg Am. 2008 Jul;90(7):1487-91. doi: 10.2106/JBJS.F.00991.

Reference Type BACKGROUND
PMID: 18594097 (View on PubMed)

Rohrl S, Nivbrant B, Mingguo L, Hewitt B. In vivo wear and migration of highly cross-linked polyethylene cups a radiostereometry analysis study. J Arthroplasty. 2005 Jun;20(4):409-13. doi: 10.1016/j.arth.2004.09.040.

Reference Type BACKGROUND
PMID: 16124954 (View on PubMed)

Rohrl SM, Li MG, Nilsson KG, Nivbrant B. Very low wear of non-remelted highly cross-linked polyethylene cups: an RSA study lasting up to 6 years. Acta Orthop. 2007 Dec;78(6):739-45. doi: 10.1080/17453670710014509.

Reference Type BACKGROUND
PMID: 18236179 (View on PubMed)

Malchau H. Revision total hip arthroplasty. Failure mechanisms and outcomes. Orthopedics. 1996 Sep;19(9):769-70. doi: 10.3928/0147-7447-19960901-17. No abstract available.

Reference Type BACKGROUND
PMID: 8887419 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2010/2621a

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Cemented vs. Cementless TKA
NCT04597684 TERMINATED NA
Exception Cementless Hip Stem
NCT04349046 ACTIVE_NOT_RECRUITING
HXLPE Vs CPE Cups Under 50 Years
NCT06706193 COMPLETED PHASE4