Evaluation of Accuracy of Continuous Glucose Monitoring (CGM) in Patients With End Stage Renal Disease (ESRD) on Intermittent Hemodialysis (iHD).

NCT ID: NCT04094064

Last Updated: 2022-12-21

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

20 participants

Study Classification

INTERVENTIONAL

Study Start Date

2020-02-19

Study Completion Date

2021-09-29

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Recent advances in continuous glucose monitors (CGMs) and availability of commercial CGM products to patients with type 1 and type 2 diabetes has made the use of CGM more widespread. CGMs work by placing a probe underneath the skin of a patient, into the interstitial space. Patients with end stage renal disease (ESRD) who are on intermittent hemodialysis (iHD) or peritoneal dialysis (PD) undergo fluid shifts between the interstitial fluid and intravascular space during dialysis treatments.These fluid shifts, uremia, acidosis, and volume overload (increase in interstitial fluid volume due to ESRD) have the potential to impact the performance of the most advanced and commercially available CGMs; however, use of CGM in these patients has not yet been studied.Use of CGM, and potentially hybrid closed loop insulin delivery systems that are dependent on accurate continuous glucose monitoring, has the potential to improve glucose control and quality of life in these patients (7). This study team feels that this study will be valuable in collecting preliminary data needed with the goal of validating the use of CGM in this patient population. The specific aim is to conduct a pilot study to evaluate the accuracy of continuous glucose monitors (CGM) in End Stage Renal Disease (ESRD) patients on intermittent hemodialysis (iHD).

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Recent advances in continuous glucose monitors (CGMs) and availability of commercial CGM products to patients with type 1 and type 2 diabetes has made the use of CGM more widespread (1). CGMs work by placing a probe underneath the skin of a patient, into the interstitial space. The probe is an electroenzymatic sensor which uses glucose oxidase to break down glucose to create hydrogen peroxidase and other elements. Hydrogen peroxidase then interacts with a base metal layer of the sensor and is oxidized, which results in release of electrons which creates a current. The current is proportional to the glucose concentration. The current is measured by the probe and transmits a calculated glucose concentration to a receiving device (2). Substances that are widely distributed in body water, and thereby present in the interstitial space, potentially affect this technology. Acetaminophen and aspirin are substances that are have been known to affect the accuracy of these devices (3); however, more recently developed CGMs such as the Dexcom G6, were able to demonstrate no interference by acetaminophen (4). Patients with end stage renal disease (ESRD) who are on intermittent hemodialysis (iHD) or peritoneal dialysis (PD) undergo fluid shifts between the interstitial fluid and intravascular space during dialysis treatments. They are also often uremic and have metabolic acidosis (5). These fluid shifts, uremia, acidosis, and volume overload (increase in interstitial fluid volume due to ESRD) have the potential to impact the performance of the most advanced and commercially available CGMs; however, use of CGM in these patients has not yet been studied (3). Moderate to severe CKD is associated with both increase in insulin resistance and decrease in insulin clearance, which results in often unpredictable and labile glucose concentrations and increased risk of hypoglycemia in these patients (6). Use of CGM, and potentially hybrid closed loop insulin delivery systems that are dependent on accurate continuous glucose monitoring, has the potential to improve glucose control and quality of life in these patients (7). This study team feels that this study will be valuable in collecting preliminary data needed with the goal of validating the use of CGM in this patient population.OBJECTIVE: The specific aim is to conduct a pilot study to evaluate the accuracy of continuous glucose monitors (CGM) in End Stage Renal Disease (ESRD) patients on intermittent hemodialysis (iHD). Accuracy will be assessed by calculating the mean absolute relative difference (MARD) between CGM values and concurrent finger stick or capillary blood glucose (CBG) in these patients during hemodialysis, and on non-dialysis days.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Diabetes Diabetes Mellitus, Type 1 Diabetes Mellitus, Type 2

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Dialysis Hemodialysis Diabetes Continuous Glucose Monitor (CGM)

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

HEALTH_SERVICES_RESEARCH

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

CGM Use while on Hemodialysis Therapy

All subjects will use a CGM for 10 days. Subjects will continue their standard of care hemodialysis treatments during the study period.

Group Type EXPERIMENTAL

Continuous Glucose Monitor

Intervention Type DEVICE

Use of a continuous glucose monitor during study period.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Continuous Glucose Monitor

Use of a continuous glucose monitor during study period.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Ages 18+
* Type 1 diabetes mellitus on intermittent HD thrice weekly OR Type 2 diabetes mellitus on intermittent HD thrice weekly
* Willingness and ability to comply with scheduled visits and study procedures

Exclusion Criteria

* Inability to comply with finger stick blood glucoses at least four times daily
* Noncompliant with HD therapies
* Pregnant women
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

DexCom, Inc.

INDUSTRY

Sponsor Role collaborator

University of Virginia

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Meaghan Stumpf, MD

Assistant Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Meaghan Stumpf, MD

Role: PRINCIPAL_INVESTIGATOR

University of Virginia

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Meaghan Stumpf, MD

Charlottesville, Virginia, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Villard O, Breton MD, Rao S, Voelmle MK, Fuller MR, Myers HE, McFadden RK, Luke ZS, Wakeman CA, Clancy-Oliveri M, Basu A, Stumpf MM. Accuracy of a Factory-Calibrated Continuous Glucose Monitor in Individuals With Diabetes on Hemodialysis. Diabetes Care. 2022 Jul 7;45(7):1666-1669. doi: 10.2337/dc22-0073.

Reference Type RESULT
PMID: 35485908 (View on PubMed)

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Document Type: Informed Consent Form

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

190012

Identifier Type: -

Identifier Source: org_study_id