New Airway for Awake Intubation (McKay Airway)

NCT ID: NCT04051424

Last Updated: 2019-08-09

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

71 participants

Study Classification

INTERVENTIONAL

Study Start Date

2018-04-04

Study Completion Date

2019-07-25

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

When endotracheal intubation is known or predicted to be difficult, patients are intubated awake using a flexible bronchoscope (awake fibre-optic intubation: AFI) so that they can protect their airway with normal upper airway muscle activity until the endotracheal tube (ETT) is safely in place. New bite blocks have been invented for bag mask ventilation but are not suitable for AFI.1 A newly invented airway device, the McKay airway, may provide a better solution for AFI by enabling jaw thrust, a condition where the upper airway is opened more as the jaw is protruded forward. It may also be more comfortable for awake users. A study is proposed to assess the functionality of the device for this purpose.

To protect the bronchoscope, a bite block is used during AFI to protect the very delicate glass fibres from damage from inadvertent biting by the patient. Currently used bite blocks protect the scope, but do not position the jaw optimally for scoping. The proposed device is an attempt to improve upon current bite blocks by both protecting the bronchoscope and positioning the jaw optimally.

Hypothesis: Residents in training in the Division of Respirology have limited experience in fibre-optic bronchoscopy and perform it under the direct supervision of an expert. Null hypothesis: the time to visualization of vocal cords with a fibre-optic bronchoscope by residents learning in the Division of Respirology will be no different with the McKay airway than with the conventional bite block or Williams Airway.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

INTRODUCTION When endotracheal intubation is known or predicted to be difficult, patients are intubated awake using a flexible bronchoscope so that they can protect their airway with normal upper airway muscle activity until the endotracheal tube (ETT) is safely in place. A newly invented airway device, the McKay airway, (Appendix 2) may provide a better solution to placing an ETT into the windpipe of an awake patient, (awake fibre-optic intubation: AFI) A study is proposed to assess the functionality of the device for this purpose.

To protect the bronchoscope, a bite block is used during AFI to protect the very delicate glass fibres from damage from inadvertent biting by the patient. Currently used bite blocks (Appendix 2, figure 5) protect the scope, but do not position the jaw or bronchoscope optimally for scoping. This is not a problem for experienced bronchoscopists such as respirologists, but can be for those, like anesthesiologists, who do bronchoscopy infrequently. For these, the proposed device may be an improvement upon current bite blocks.

Hypothesis: Residents in training in the Division of Respirology have limited experience in fibre-optic bronchoscopy and perform it under the direct supervision of an expert. Null hypothesis: the time to visualization of vocal cords with a fibre-optic bronchoscope by residents learning in the Division of Respirology will be no different with the McKay airway than with the conventional bite block.

Experimental design: The proposed experiment is an unblinded repeated measures interventional clinical trial with concealed randomization of which device is used first and which second. Randomization will be by a computer-generated random number table (1s and 2s where 1 is conventional bite block is used first and 2 means McKay airway first) transcribed to paper cards in numbered opaque envelopes to be opened just prior to bronchoscopy.

Primary outcome: Time from beginning insertion of bronchoscope into the bite block to visualization of vocal cords.

Secondary outcomes: Scores will be recorded on rating scales for: ease of insertion, ease of obtaining proper position of teeth in the device by patients, assessment of gag reflex. Comments about overall impression will be recorded.

Participants: Participants are of two kinds, patients and residents. Patients will be consenting patients booked for bronchoscopy by pulmonologists at Royal University Hospital. Excepted patients will be those who do not wish to participate and those with any health conditions that the attending pulmonologist feels puts them at any added risk by participating.

Consent: With University of Saskatchewan Research Ethics Board approval, the investigators will recruit patients and obtain signed informed consent at the time of booking bronchoscopy or on arrival for bronchoscopy.

Data and privacy concerns: As well as the primary and secondary outcomes, data collection on paper data sheets will include basic demographics. These are: age, gender, height, weight, and diagnosis as well as airway characteristics (see Appendix 1, Data Sheet). Because this may identify patients and breach their privacy, the data sheets will be identified only by number. The de-identified data collection sheets will be labeled with a unique numerical identifier (e.g., 1, 2, 3, etc). The data collection sheet will be linked to the patient Personal Health Number by way of a physically separate Master Data list (e.g., 1, 2, 3, etc.). (See attached - Master Data List) The de-identified data from the data collection sheet (See Attached - Data Collection Sheet) will be transcribed by Dr. McKay to data base on a password protected computer kept in a locked office in the Department of Anesthesiology at all times. Identifiable patient information will not be transcribed electronically. Upon completion of the study, Dr McKay will store electronic data files and paper forms in a locked filing cabinet in the Department of Anesthesiology (accessible only by key code), as per the University of Saskatchewan Research Integrity Policy (http://www.usask.ca/university\_secretary/policies/research/8\_25.php). The Master Data List (paper only) will be stored in a physically separate location from the data collection forms. The hard copies of the data collection forms, master list, and completed consent forms will be destroyed through the confidential paper disposal services of the SHR, while the electronic data will be permanently deleted after 5 years as per the above University of Saskatchewan Research Integrity Policy. We anticipate this data to be the basis for a publication in a peer-reviewed scientific journal and at a national scientific meeting.

Patient safety: The experiment will be overseen by the attending specialist respirologist who will intervene immediately as needed and proceed as clinically indicated if any issue of patient safety arises at any time. This is normal practice. We expect that risk to participating patients is minimal. We anticipate the following incidence: 1) common (1-10%) side effects: none. 2) uncommon (0.1 to 1%) side effects: mild abrasion of the mouth (which can occur with the currently available awake intubation bite blocks and airways as often). 3) rare (0.01-0.1%) side effects: zero. 4) Very rare (\<0.01%) side effects: sensitivity to the plastic with irritation of the oral mucosa (which can occur with the currently available awake intubation plastic bite blocks and airways as often). The McKay airway is made of medical grade plastic. 5) Severe side effects: zero (prolonged hospital admission, admission to intensive care, loss of limb or vital organ, or death). We believe that risk of participation is not different from risk of bronchoscopy, and is safe in expert hands.

Measurements. With a stopwatch, the investigator will measure the time from beginning to place the bronchoscope in the mouth following topicalization to visualization of vocal cords or epiglottis. Following bronchoscopy, the Respirologist will rate the modalities with rating scales (see attached Data Sheet).

Number of participants: There is no similar study from which to calculate sample size. We will initially assuming that one modality is 0.2 times faster with standard deviation 0.2, paired t-test sample size is calculated at n = 10, then recalculate based on the primary outcome findings.

Statistical analysis. Demographic and rating data will be tabulated as observational; time measurements compared by paired t-test or Mann-Whitney U test as mean ± standard deviation and \[95% Confidence Intervals\] or median and \[interquartile range\] as appropriate following a Kolmogorov-Smirnov test of normality.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Healthy

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Design: The proposed experiment is a randomized clinical crossover (repeated measures) trial of three oral bite-block devices with device order randomized and blinded prior to recruitment.
Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

ConMed bite block

Standard bite block (Conmed Bite Block; Conmed Corp., Utica NY, USA)

Group Type ACTIVE_COMPARATOR

McKay airway

Intervention Type DEVICE

Investigator will fit McKay airway in patient's mouth and bronchoscopist will try to visualize the vocal cords.

Williams Airway

Intervention Type DEVICE

Investigator will fit Williams Airway in patient's mouth and bronchoscopist will try to visualize the vocal cords.

Williams Airway

Williams Airway Intubator (Williams Airway Intubator Ltd, Calgary, Canada)

Group Type ACTIVE_COMPARATOR

ConMed bite block

Intervention Type DEVICE

Investigator will fit ConMed bite block in patient's mouth and bronchoscopist will try to visualize the vocal cords.

McKay airway

Intervention Type DEVICE

Investigator will fit McKay airway in patient's mouth and bronchoscopist will try to visualize the vocal cords.

McKay airway

A new device that enables maintenance of jaw thrust. (US patent application 16/098,530)

Group Type EXPERIMENTAL

ConMed bite block

Intervention Type DEVICE

Investigator will fit ConMed bite block in patient's mouth and bronchoscopist will try to visualize the vocal cords.

Williams Airway

Intervention Type DEVICE

Investigator will fit Williams Airway in patient's mouth and bronchoscopist will try to visualize the vocal cords.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

ConMed bite block

Investigator will fit ConMed bite block in patient's mouth and bronchoscopist will try to visualize the vocal cords.

Intervention Type DEVICE

McKay airway

Investigator will fit McKay airway in patient's mouth and bronchoscopist will try to visualize the vocal cords.

Intervention Type DEVICE

Williams Airway

Investigator will fit Williams Airway in patient's mouth and bronchoscopist will try to visualize the vocal cords.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Participants are of two kinds, first, anesthesiologists and anesthesia residents who will perform partial bronchoscopy, and
* secondly, healthy volunteers. Healthy volunteers will be recruited from hospital staff, residents and students at Royal University Hospital.

Exclusion Criteria

* Excepted anesthesiologists and residents will be those who do not wish to participate in the study.
* Excepted volunteers will be those who do not wish to participate in the study and those with a lidocaine allergy.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Saskatchewan

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

William McKay

M.D.

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

William P McKay, MD

Role: PRINCIPAL_INVESTIGATOR

Professor Emeritus

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Saskatoon Health Region, 410 22nd Street East

Saskatoon, Saskatchewan, Canada

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Canada

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

BIO 17 - 202

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Awake Intubation V-MAC VS