Assessment of Risk Factors for Appropriate ICD (Implantable Cardioverter-defibrillator) Intervention in Patients With Ischemic Cardiomyopathy
NCT ID: NCT04014946
Last Updated: 2020-09-29
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
200 participants
INTERVENTIONAL
2012-07-24
2020-07-22
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
General objective: analysis of baseline risk factors to identify predictors for appropriate ICD intervention in patients with ischemic cardiomyopathy receiving an ICD for primary prevention (MADIT II population).
Hypothesis: The primary alternative hypothesis states that the mean relative infarct transmurality (RIT) is different in patients with (RITshock or ATP (Anti Tachy Pacing)) and without (RITno shock or ATP )appropriate ICD intervention, i.e. shock or ATP.
* Null hypothesis (H0): RITshock or ATP = RITno shock or ATP
* Alternative hypothesis (Ha): RITshock or ATP ≠ RITno shock or ATP
Sample size: 200 patients.
Follow-up: Enrolment visit, pre implant screening, ICD implantation, pre-hospital discharge visit, and follow-up (FUP) visits at 2, 6, 12, 18, 24 months including home monitoring. Additional routine FUP every 6 months until study termination after last enrolled patient has completed 2 years FUP.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
A PRospective, rAndomizEd Comparison of subcuTaneOous and tRansvenous ImplANtable Cardioverter Defibrillator Therapy
NCT01296022
A Critical Pathway for Implantable Cardioverter-Defibrillators in Patients With Ischemic Cardiomyopathy
NCT01248702
Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators in Europe
NCT02064192
Resynchronization in Paced Heart Failure Patients With Implantable Cardioverter Defibrillator (ICD) Indication
NCT01415024
Reduction of Inappropriate Shocks of Implantable Cardioverter Defibrillators (ICDs) With Enhanced SVT Discriminators
NCT01963286
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
PARCADIA is a prospective non-randomized non-interventional multi-center clinical investigation in Europe. Patients with depressed LV (Left Ventricular) function assessed on local standards, of ischemic (at least 40 days post-MI (myocardial infarction) or 3 months post revascularization) origin and on chronic optimal medical therapy will be selected according to inclusion and exclusion criteria, implanted with an ICD after executing baseline investigations and prospectively followed up for minimal 24 months and until the termination of the clinical investigation
General objective: analysis of baseline risk factors to identify predictors for appropriate ICD intervention in patients with ischemic cardiomyopathy receiving an ICD for primary prevention (MADIT II population).
The primary objective of the clinical investigation is to determine whether there is a relationship between appropriate ICD intervention (shock or ATP) and the Relative Infarct Transmurality (RIT) obtained from Late Gadolinium Enhanced Cardiac Magnetic Resonance (LGE-CMR) imaging in patients with ischemic cardiomyopathy, receiving an ICD for primary prevention.
Methodology: Screening: (within 6 months before enrolment) patients with LV depressed function due to Ischemic Cardiomyopathy with an indication for primary prevention ICD implantation according to ESC (European Society of Cardiology) guidelines or local standards will be screened within 6 months before enrolment.
pre implant diagnostics: within 3 months after enrolment LGE-CMR imaging, 24h holter, 12-lead ECG, will be performed and biochemical markers will be obtained.
ICD implantation: Implantation of a Lumax 540 single/dual chamber ICD or successor withiin 3 months after enrolment. The ICD will be programmed according to protocol.
Pre-hospital discharge an ICD interrogation wil be performed. Follow-up (FUP) visits at: 2, 6, 12, 18, 24 months with inclusion of standard 12-lead ECG, ICD check-up and cardiologist visit in the outpatient clinic. Additional routine FUP every 6 months until study termination after last enrolled patient has completed 2 years FUP.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
The endpoints related to the primary hypothesis are appropriate ICD intervention (shock or ATP) and Relative Infarct Transmurality (RIT = transmural infarct mass / total infarct mass) obtained from LGE-CMR. ICD interventions will be labeled appropriate or non-appropriate by an independent endpoint committee.
* RITshock or ATP: RIT expectation value in patients with ≥1 appropriate shock or ATP therapy until the 24mo follow-up
* RIT no shock or ATP: RIT expectation value in patients without any appropriate shock or ATP therapy until the 24mo follow-up
PREVENTION
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
ICD implantation
Implantation of a Lumax 540 single/dual chamber ICD or successor according to local practice within 3 months after enrolment. The patient will be implanted with a single or dual chamber device according to ESC guidelines.
ICD implantation
implantation of the Lumax 540 single/dual chamber ICD or successor
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
ICD implantation
implantation of the Lumax 540 single/dual chamber ICD or successor
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Written informed consent / willingness and ability to comply with the protocol
Exclusion Criteria
* Severe renal dysfunction (stage 4 or 5) resulting in contra-indication for the admission of gadolinium during MRI (See Appendix A for more details)
* Indication for secondary prevention ICD implantation
* Class I indication for cardiac resynchronization therapy
* Heart failure with New York Heart Association functional class IV
* LV ejection fraction \>40%
* Age \<18 years and \>85 years
* Women that are pregnant, lactating or planning to become pregnant
* Participating in any other clinical trial with active intervention(s) during the course of this study
* Life expectancy less than 1 year
18 Years
85 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Biotronik SE & Co. KG
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
TA97
Identifier Type: -
Identifier Source: org_study_id