The Effects of Different Activation Protocols of Hycon Device and Vibration Stimulation on Canine Teeth Distalization

NCT ID: NCT03968263

Last Updated: 2019-10-04

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

25 participants

Study Classification

INTERVENTIONAL

Study Start Date

2019-02-08

Study Completion Date

2021-02-08

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study will be performed with 25 patients who applied to Erciyes University Faculty of Dentistry for treatment and who need 2 first premolar extraction and maximum anchorage for treatment. In order to increase anchorage in the patient who will start the distalization of canine, mini screw (1.5 mm diameter, 7 mm length) will be applied to the right and left maxillary dentition of the patient under local anesthesia. The hycon device, which has a screw-shaped design for the application of force to both the right and left sides of the maxillary dentition of the patients, will be adapted to the bands in the 1st molar teeth. Patients will be randomly divided into 4 groups. Vibration will be applied to the two groups with the Acceledent device.

Group 1 = The hycon device in this group will be used in accordance with the manufacturer's instructions.

Group 2 = The activation period of the hycon device in this group will be modified.

Group 3 = The hycon device in this group will be used in accordance with the manufacturer's instructions. In addition, patients in this group twice a day for 10 minutes with acceledent device vibration will be applied.

Group 4 = The activation period of the hycon device in this group will be modified. In addition, patients in this group twice a day for 10 minutes with acceledent device vibration will be applied.

The period of canine distalization of orthodontic treatment is one of the important stages affecting the duration of treatment. Shortening this time in the clinic will shorten the duration of treatment.

If this application changes the tooth movement speed in any direction, it will support the new research.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This study is planned as a splint mouth, randomized, non-controlled clinical trial.This study will be performed with 25 patients who applied to Erciyes University Faculty of Dentistry for treatment and who need 2 first premolar extraction and maximum anchorage for treatment.Patients will be selected from 12 to 18 years of age.In order to increase anchorage in the patient who will start the distalization of canine, mini screw (PSM Medical Solutions, Quattro Standard Screw 1,5x7mm, Tuttlingen,Germany) will be applied to the right and left maxillary dentition of the patient under local anesthesia.The hycon device (Adenta,Germany), which has a screw-shaped design for the application of force to both the right and left sides of the maxillary dentition of the patients, will be adapted to the bands in the 1st molar teeth.The approval of the study was taken from Erciyes University Clinical Research Ethics Committee in Kayseri (2018/337).Informed consent will be obtained from all patients included in the study.Consent will be taken from parents of those under the age of 18. At the beginning of the treatment and at the end of the treatment, all patients who participated in the study received standard treatment records including photographs, dental models and radiography.

Inclusion criteria:

* No systemic disease
* Being healthy as periodontal.
* No smoking.
* No previous orthodontic treatment.
* Lack of congenital tooth deficiency
* Permanent dentition
* Indication of extraction for 1.premolar in the maxilla
* There is no restoration of upper canine teeth.
* Indication of the use of mini screw for maximum anchoring in the maxilla

All models will be scanned by 3D laser model scanning device (3 Shape, R 700 Desktop Scanner, Szczecin, Poland) and digitalized (3Shape Ortho Analyzer ™ 12). The gradient of the teeth and the amount of space closure will be examined by using panoramic radiographs. The amount of root resorption in canine teeth will be measured by using periapical radiography. As a result of the data obtained, the effects of the hycon device(Adenta, Germany) and vibration device(Acceledent Aura, OrthoAccel Technologies, Inc. USA) on the tooth movement speed will be compared.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Tooth Migration

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Routine orthodontic treatment procedures will be applied to patients
Primary Study Purpose

TREATMENT

Blinding Strategy

DOUBLE

Participants Outcome Assessors
It will not be possible to prevent clinicians and their interventions.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Hycon device(Routine protocol)

The hycon device in this group will be activeted into half turn every 3 days in accordance with the manufacturer's instructions.

Group Type ACTIVE_COMPARATOR

Hycon device(Routine protocol)

Intervention Type DEVICE

Hycon device will be activated half a turn every 3 days.

Hycon device(Modified protocol)

Intervention Type DEVICE

The activation period of the hycon device will be modified.

Hycon device(Routine protocol) and Vibration(Acceledent)

Intervention Type DEVICE

Hycon device will be activated half a turn every 3 days. Vibration will be applied 2 times 10 minutes per day.

Hycon device(Modified protocol) and Vibration(Acceledent)

Intervention Type DEVICE

The activation period of the hycon device will be modified. Vibration will be applied 2 times 10 minutes per day.

Hycon device(Modified protocol)

The activation period of the hycon device in this group will be modified. The first day will be clockwise half a turn, the second day will be half-turn clockwise and the third day will be turned half a turn counterclockwise.

Group Type ACTIVE_COMPARATOR

Hycon device(Routine protocol)

Intervention Type DEVICE

Hycon device will be activated half a turn every 3 days.

Hycon device(Modified protocol)

Intervention Type DEVICE

The activation period of the hycon device will be modified.

Hycon device(Routine protocol) and Vibration(Acceledent)

Intervention Type DEVICE

Hycon device will be activated half a turn every 3 days. Vibration will be applied 2 times 10 minutes per day.

Hycon device(Modified protocol) and Vibration(Acceledent)

Intervention Type DEVICE

The activation period of the hycon device will be modified. Vibration will be applied 2 times 10 minutes per day.

Hycon device(Routine protocol) and Vibration

The hycon device in this group will be activeted into half turn every 3 days in accordance with the manufacturer's instructions. In addition, patients in this group twice a day for 10 minutes with acceledent device vibration will be applied.

Group Type ACTIVE_COMPARATOR

Hycon device(Routine protocol)

Intervention Type DEVICE

Hycon device will be activated half a turn every 3 days.

Hycon device(Modified protocol)

Intervention Type DEVICE

The activation period of the hycon device will be modified.

Hycon device(Routine protocol) and Vibration(Acceledent)

Intervention Type DEVICE

Hycon device will be activated half a turn every 3 days. Vibration will be applied 2 times 10 minutes per day.

Hycon device(Modified protocol) and Vibration(Acceledent)

Intervention Type DEVICE

The activation period of the hycon device will be modified. Vibration will be applied 2 times 10 minutes per day.

Hycon device(Modified protocol) and Vibration

The activation period of the hycon device in this group will be modified. The first day will be clockwise half a turn, the second day will be half-turn clockwise and the third day will be turned half a turn counterclockwise. In addition, patients in this group twice a day for 10 minutes with acceledent device vibration will be applied.

Group Type ACTIVE_COMPARATOR

Hycon device(Routine protocol)

Intervention Type DEVICE

Hycon device will be activated half a turn every 3 days.

Hycon device(Modified protocol)

Intervention Type DEVICE

The activation period of the hycon device will be modified.

Hycon device(Routine protocol) and Vibration(Acceledent)

Intervention Type DEVICE

Hycon device will be activated half a turn every 3 days. Vibration will be applied 2 times 10 minutes per day.

Hycon device(Modified protocol) and Vibration(Acceledent)

Intervention Type DEVICE

The activation period of the hycon device will be modified. Vibration will be applied 2 times 10 minutes per day.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Hycon device(Routine protocol)

Hycon device will be activated half a turn every 3 days.

Intervention Type DEVICE

Hycon device(Modified protocol)

The activation period of the hycon device will be modified.

Intervention Type DEVICE

Hycon device(Routine protocol) and Vibration(Acceledent)

Hycon device will be activated half a turn every 3 days. Vibration will be applied 2 times 10 minutes per day.

Intervention Type DEVICE

Hycon device(Modified protocol) and Vibration(Acceledent)

The activation period of the hycon device will be modified. Vibration will be applied 2 times 10 minutes per day.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* No systemic disease
* Being healthy as periodontal.
* No smoking.
* No previous orthodontic treatment.
* Lack of congenital tooth deficiency
* Permanent dentition
* Indication of extraction for 1.premolar in the maxilla
* There is no restoration of upper canine teeth.
* Indication of the use of mini screw for maximum anchoring in the maxilla

Exclusion Criteria

* Orthodontic treatment history
* Missing tooth
* Poor oral hygiene
* Lack of cooperation
Minimum Eligible Age

12 Years

Maximum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

TC Erciyes University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Ahmet Yağcı

Associate Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Osman Yildiz, Research as.

Role: STUDY_CHAIR

Research as.

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Erciyes University, Faculty of Dentistry, Department of Orthodontics University university

Kayseri, Melikgazi, Turkey (Türkiye)

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Turkey (Türkiye)

References

Explore related publications, articles, or registry entries linked to this study.

McLaughlin RP, Kalha AS, Schuetz W. An alternative method of space closure: the Hycon Device. J Clin Orthod. 2005 Aug;39(8):474-84; quiz 471. No abstract available.

Reference Type BACKGROUND
PMID: 16247198 (View on PubMed)

Elmotaleb MAA, Elnamrawy MM, Sharaby F, Elbeialy AR, ElDakroury A. Effectiveness of using a Vibrating Device in Accelerating Orthodontic Tooth Movement: A Systematic Review and Meta-Analysis. J Int Soc Prev Community Dent. 2019 Jan-Feb;9(1):5-12. doi: 10.4103/jispcd.JISPCD_311_18. Epub 2019 Feb 14.

Reference Type BACKGROUND
PMID: 30923687 (View on PubMed)

Related Links

Access external resources that provide additional context or updates about the study.

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

TDH-2019-8701

Identifier Type: OTHER_GRANT

Identifier Source: secondary_id

TDH-2019-8701

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Distalization by Miniscrew
NCT02427282 COMPLETED PHASE1