The Effects of Different Activation Protocols of Hycon Device and Vibration Stimulation on Canine Teeth Distalization
NCT ID: NCT03968263
Last Updated: 2019-10-04
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
25 participants
INTERVENTIONAL
2019-02-08
2021-02-08
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Group 1 = The hycon device in this group will be used in accordance with the manufacturer's instructions.
Group 2 = The activation period of the hycon device in this group will be modified.
Group 3 = The hycon device in this group will be used in accordance with the manufacturer's instructions. In addition, patients in this group twice a day for 10 minutes with acceledent device vibration will be applied.
Group 4 = The activation period of the hycon device in this group will be modified. In addition, patients in this group twice a day for 10 minutes with acceledent device vibration will be applied.
The period of canine distalization of orthodontic treatment is one of the important stages affecting the duration of treatment. Shortening this time in the clinic will shorten the duration of treatment.
If this application changes the tooth movement speed in any direction, it will support the new research.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Corticotomy-Assisted Class III Elastic Applications
NCT06763900
"Three Dimensional Assessment of Maxillary Molars Following Distalization Using Two Different Approaches"
NCT06240923
Evaluation Of Anchorage Control During Canine Retraction Using Arch Wire Stopper Versus Mini-Screws
NCT06416904
Evaluation of the Periodontal Status After the Treatment of Palatally Impacted Canines Using Acceleration Procedures
NCT05644678
Distalization With Aligners: Anchorage Options
NCT06631131
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Inclusion criteria:
* No systemic disease
* Being healthy as periodontal.
* No smoking.
* No previous orthodontic treatment.
* Lack of congenital tooth deficiency
* Permanent dentition
* Indication of extraction for 1.premolar in the maxilla
* There is no restoration of upper canine teeth.
* Indication of the use of mini screw for maximum anchoring in the maxilla
All models will be scanned by 3D laser model scanning device (3 Shape, R 700 Desktop Scanner, Szczecin, Poland) and digitalized (3Shape Ortho Analyzer ™ 12). The gradient of the teeth and the amount of space closure will be examined by using panoramic radiographs. The amount of root resorption in canine teeth will be measured by using periapical radiography. As a result of the data obtained, the effects of the hycon device(Adenta, Germany) and vibration device(Acceledent Aura, OrthoAccel Technologies, Inc. USA) on the tooth movement speed will be compared.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Hycon device(Routine protocol)
The hycon device in this group will be activeted into half turn every 3 days in accordance with the manufacturer's instructions.
Hycon device(Routine protocol)
Hycon device will be activated half a turn every 3 days.
Hycon device(Modified protocol)
The activation period of the hycon device will be modified.
Hycon device(Routine protocol) and Vibration(Acceledent)
Hycon device will be activated half a turn every 3 days. Vibration will be applied 2 times 10 minutes per day.
Hycon device(Modified protocol) and Vibration(Acceledent)
The activation period of the hycon device will be modified. Vibration will be applied 2 times 10 minutes per day.
Hycon device(Modified protocol)
The activation period of the hycon device in this group will be modified. The first day will be clockwise half a turn, the second day will be half-turn clockwise and the third day will be turned half a turn counterclockwise.
Hycon device(Routine protocol)
Hycon device will be activated half a turn every 3 days.
Hycon device(Modified protocol)
The activation period of the hycon device will be modified.
Hycon device(Routine protocol) and Vibration(Acceledent)
Hycon device will be activated half a turn every 3 days. Vibration will be applied 2 times 10 minutes per day.
Hycon device(Modified protocol) and Vibration(Acceledent)
The activation period of the hycon device will be modified. Vibration will be applied 2 times 10 minutes per day.
Hycon device(Routine protocol) and Vibration
The hycon device in this group will be activeted into half turn every 3 days in accordance with the manufacturer's instructions. In addition, patients in this group twice a day for 10 minutes with acceledent device vibration will be applied.
Hycon device(Routine protocol)
Hycon device will be activated half a turn every 3 days.
Hycon device(Modified protocol)
The activation period of the hycon device will be modified.
Hycon device(Routine protocol) and Vibration(Acceledent)
Hycon device will be activated half a turn every 3 days. Vibration will be applied 2 times 10 minutes per day.
Hycon device(Modified protocol) and Vibration(Acceledent)
The activation period of the hycon device will be modified. Vibration will be applied 2 times 10 minutes per day.
Hycon device(Modified protocol) and Vibration
The activation period of the hycon device in this group will be modified. The first day will be clockwise half a turn, the second day will be half-turn clockwise and the third day will be turned half a turn counterclockwise. In addition, patients in this group twice a day for 10 minutes with acceledent device vibration will be applied.
Hycon device(Routine protocol)
Hycon device will be activated half a turn every 3 days.
Hycon device(Modified protocol)
The activation period of the hycon device will be modified.
Hycon device(Routine protocol) and Vibration(Acceledent)
Hycon device will be activated half a turn every 3 days. Vibration will be applied 2 times 10 minutes per day.
Hycon device(Modified protocol) and Vibration(Acceledent)
The activation period of the hycon device will be modified. Vibration will be applied 2 times 10 minutes per day.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Hycon device(Routine protocol)
Hycon device will be activated half a turn every 3 days.
Hycon device(Modified protocol)
The activation period of the hycon device will be modified.
Hycon device(Routine protocol) and Vibration(Acceledent)
Hycon device will be activated half a turn every 3 days. Vibration will be applied 2 times 10 minutes per day.
Hycon device(Modified protocol) and Vibration(Acceledent)
The activation period of the hycon device will be modified. Vibration will be applied 2 times 10 minutes per day.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Being healthy as periodontal.
* No smoking.
* No previous orthodontic treatment.
* Lack of congenital tooth deficiency
* Permanent dentition
* Indication of extraction for 1.premolar in the maxilla
* There is no restoration of upper canine teeth.
* Indication of the use of mini screw for maximum anchoring in the maxilla
Exclusion Criteria
* Missing tooth
* Poor oral hygiene
* Lack of cooperation
12 Years
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
TC Erciyes University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Ahmet Yağcı
Associate Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Osman Yildiz, Research as.
Role: STUDY_CHAIR
Research as.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Erciyes University, Faculty of Dentistry, Department of Orthodontics University university
Kayseri, Melikgazi, Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
McLaughlin RP, Kalha AS, Schuetz W. An alternative method of space closure: the Hycon Device. J Clin Orthod. 2005 Aug;39(8):474-84; quiz 471. No abstract available.
Elmotaleb MAA, Elnamrawy MM, Sharaby F, Elbeialy AR, ElDakroury A. Effectiveness of using a Vibrating Device in Accelerating Orthodontic Tooth Movement: A Systematic Review and Meta-Analysis. J Int Soc Prev Community Dent. 2019 Jan-Feb;9(1):5-12. doi: 10.4103/jispcd.JISPCD_311_18. Epub 2019 Feb 14.
Related Links
Access external resources that provide additional context or updates about the study.
pubmed ID not found
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
TDH-2019-8701
Identifier Type: OTHER_GRANT
Identifier Source: secondary_id
TDH-2019-8701
Identifier Type: -
Identifier Source: org_study_id