Non Invasive Use of Pressure-Volume Loop in the Operating Room
NCT ID: NCT03921164
Last Updated: 2024-06-24
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
42 participants
OBSERVATIONAL
2021-01-27
2021-10-22
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Rational for the Use of Velocity-Pressure Loop in the Operating Room
NCT03853226
Dynamic Estimation of Cardiac Output in the Operating Room
NCT04926220
Decision Support for Intraoperative Low Blood Pressure
NCT02726620
Cerebral Perfusion During Induction of General Anesthesia
NCT03769142
Cerebral Perfusion Variation During Blood Pressure Changes in ICU
NCT05804773
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
In a pilot study investigators described a method for analyzing Velocity-Pressure interactions to monitor ventricular afterload in the operating room with the construction of Velocity-Pressure aortic loops (VP Loop).
These loops were constructed from an aortic velocity signal measured by esophageal Doppler and aortic blood pressure signal from a femoral catheter. The Global Afterload Angle (GALA) measured on the loop were then higher in patients at cardiovascular risk (RCV+) at 68 ± 6° compared to 41 ± 15° in patients (RCV-) (p\<0.001). In addition, GALA variations were associated with variations in the three components of ventricular afterload: compliance, resistance and waves reflection. Finally, under the effect of vasopressors, there was a modification in the shape of the VP Loop and the value of GALA, showing GALA as a reliable marker potential for ventricular afterload in patients under general anesthesia.
In order to develop a totally non-invasive method that would produce a pressure velocity curve, the investigators propose to combine an estimation of aortic pressure by a tonometry method and an estimation of ventricular volumes by three-dimensional echocardiography.
The main objective of this study is then to compare VP Loop parameters obtained non-invasively to VP loop obtained invasively according to patient cardiovascular risk factors.
Cardiac afterload can be schematically defined by the combination of three components: peripheral vascular resistance (PVR), total arterial compliance (Ctot) and aortic wave reflections (WR). WR could be assessed by pulse wave pressure analysis with the augmentation index (Aix) or after pulse wave pressure separation into a forward and backward wave with the wave reflection index (WRi) or the wave reflection area (WRa).
Invasive Aortic pressure measurements: As required by the standard of care of the interventional neuroradiology procedure, the neuroradiologist also cannulated the femoral artery. At the end of the procedure, during catheter withdrawal, pressure waveforms are recorded in the descending thoracic aorta just in front of the esophageal Doppler probe.
Descending aortic velocity is measured with a transesophageal Doppler CardioQ-ODM+ monitor (Deltex Medical, Chichester, UK) in order to construct the VP Loop in descending thoracic aorta.
Non-invasive Non-invasive Aortic velocity recording VP Loop in aorta is measured in the flushing chamber of the left ventricle from the apical five chamber view by trans-thoracic echocardiography (TTE) (Philips, EPIQ 7).
Estimation of ventricular diastolic pressure by measuring mitral and aortic flow gradients by echocardiography (EPIQ G7 Philips© or similar) Determination of left ventricular volumes during the cardiac cycle by echocardiography (3D EPIQ G7 Philips© or similar).
Non-invasive central pressure measurement by an arterial tonometer reconstructing the central aortic curve (ShygmoCor, AtCor©) The SphygmoCor radial tonometer (AtCor Medical, Pty Ltd, Sydney, Australia) is the most widely used tonometer in clinical research for non-invasive central pressure measurement and pulse wave analysis. The central blood pressure is then estimated using a validated radial-aortic transfer function.
The tonometer requires prior calibration by mean (MAP) and diastolic (PAD) blood pressure measured with the conventional brachial cuff as validated in the literature.
VP Loop construction Digitalization of pressure and velocity signals are performed with the IntelliVue MP60 monitor (Philips, Eindhoven, The Netherlands) at a sampling frequency of 125 Hz and saved using ixTrend software (IXELLENCE, Wildau, Germany) on a computer. Briefly, the velocity coordinates is plotted on the x axis and the pressure coordinates on the y axis. The investigators characterize the VP Loop by 4 points (A, B, C, D), allowing us to identify 3 angles: Alpha, Beta and GALA.
The goal of this study is to compare these parameters of cardiac after load obtained non-invasively with the same parameters invasively obtained.
Experimental design: This is a single-center, interventional, category II prospective study (minimal risks and constraints)
Population concerned: Patients will be included if their perioperative risk required a continuous monitoring of mean arterial pressure (MAP) and cardiac output (CO). The study involves major patients under general anesthesia in interventional neuroradiology.
Research Proceedings For all patients, data from trans-esophageal Doppler, trans-thoracic echocardiography (TTE) and hemodynamic data are collected at the end of the procedure. During catheter withdrawal, pressure waveforms are recorded in the descending thoracic aorta just in front of the esophageal Doppler probe. All data from monitoring are connected to the main monitor.
Individual benefit: There is no benefit for the patient
Collective benefit: Targeting mean arterial pressure (MAP) with boluses of selective peripheral vasopressors (without positive inotropic or chronotropic effects) could have deleterious effects on cardiac output. Thus, it seems important to use a combined analysis of MAP and CO with low invasive methods to estimate the Afterload-related cardiac performance (ACP) in surgical patients considered with "high cardiovascular risk".
Risks and minimal constraints added by the research:
No added risk. Patients are included if their perioperative risk required a continuous monitoring of MAP and CO. The standard of care for the interventional neuroradiology procedure needs a catheterization of the femoral artery using the Seldinger technique and insertion of a catheter. All the other ones measures are obtained non-invasively. Patients are assigned to one of two groups according to their risk of increased arterial stiffness as reported in cardiological publications. The criteria investigators used are as follows: age \> 50 years old as a major criterion 20 and cardio-vascular risk factors (history of congestive heart failure, history of cardiovascular event, current smoking, diabetes mellitus, dyslipidemia, and arterial hypertension) as minor criteria. Patients were classified into the high risk group (Hi-risk) if they had at least one major criterion or two minor criteria or into the low risk group (Lo-risk) if they presented with no or one minor criterion. During their interventional neuroradiology procedure, all patients' routine monitoring will consist of electrocardiogram, pulsated oxygen saturation, endtidal carbon dioxide (CO2), respiratory rate, tidal volume and monitoring of neuromuscular function.
For all patients whatever the comorbidities, anesthesia induction will be performed using a target-controlled infusion (Orchestra® Base Primea Fresenius Kabi France). According to our standard of care, intra-operative episodes of hypotension (mean arterial pressure (MAP) \< 65 mmHg or \< 80% baseline) are treated by Norepinephrine bolus of 10 µg. For all patients, data from trans-esophageal Doppler, trans-thoracic echocardiography (TTE) and hemodynamic data are collected at the end of the procedure.
Number of selected subjects Selection of patients up to 55 analyzable patients Number of centers: 1 Research center Agenda inclusion period: 12 months duration of participation (treatment + follow-up): duration of the interventional neuroradiology procedure: 1 day Total duration: 12 months Number of planned inclusions by center and month: 2-3 Number of subjects required: 55
Statistics: Continuous data are expressed in median \[interquartile\] and qualitative data in n (%). The risk α has been set at 5%. The categorical variables will be compared by Mann-Whitney test and the continuous variables by Wilcoxon test.
The concordance between the two methods will be evaluated by the intra-class correlation coefficient as well as by the Bland-Altman representation (with determination of bias and approval limits) for the various parameters of interest.
Selection of patients until 55 analyzable patients is obtained (signal quality obtained and possible analysis). The estimate of the number of subjects to be included is based on the main evaluation criterion, the intra-class correlation coefficient. Thus, to highlight, an intra-class correlation coefficient of 0.9 with a confidence interval of 0.1, for an alpha risk of 5%, it is necessary to include 56 patients.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
OTHER
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Patients scheduled for a neuroradiology procedure
Interventional neuroradiology procedure under general anesthesia requiring a continuous monitoring of mean arterial pressure and cardiac output, including electrocardiogram, pulsated oxygen saturation, endtidal CO2, respiratory rate, tidal volume and monitoring of neuromuscular function. In addition, for all patients, data from trans-oesophageal Doppler, trans-thoracic echocardiography (TTE) and hemodynamic data are collected at the end of the procedure. During catheter withdrawal, pressure waveforms are recorded in the descending thoracic aorta just in front of the esophageal Doppler probe.
Trans-oesophageal Doppler
As required by the standard of care of the interventional neuroradiology procedure, the neuroradiologist also cannulates the femoral artery. At the end of the procedure, during catheter withdrawal, pressure waveforms are recorded in the descending thoracic aorta just in front of the esophageal Doppler probe.
Descending aortic velocity is measured with a transesophageal Doppler CardioQ-ODM+ (Deltex Medical, Chichester, UK) in order to construct the VP Loop in descending thoracic aorta.
Trans-thoracic echocardiography
Estimation of ventricular diastolic pressure by measuring mitral and aortic flow gradients by echocardiography (EPIQ G7 Philips© or similar) Determination of left ventricular volumes during the cardiac cycle by echocardiography (3D EPIQ G7 Philips© or similar).
Applanation tonometry
Measurements using the SphygmoCor radial tonometer (AtCor Medical, Pty Ltd, Sydney, Australia), the most widely used tonometer in clinical research for non-invasive central pressure measurement and pulse wave analysis. The central blood pressure is then estimated using a validated radial-aortic transfer function.
The tonometer requires prior calibration by mean (MAP) and diastolic (PAD) blood pressure measured with the conventional brachial cuff as validated in the literature.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Trans-oesophageal Doppler
As required by the standard of care of the interventional neuroradiology procedure, the neuroradiologist also cannulates the femoral artery. At the end of the procedure, during catheter withdrawal, pressure waveforms are recorded in the descending thoracic aorta just in front of the esophageal Doppler probe.
Descending aortic velocity is measured with a transesophageal Doppler CardioQ-ODM+ (Deltex Medical, Chichester, UK) in order to construct the VP Loop in descending thoracic aorta.
Trans-thoracic echocardiography
Estimation of ventricular diastolic pressure by measuring mitral and aortic flow gradients by echocardiography (EPIQ G7 Philips© or similar) Determination of left ventricular volumes during the cardiac cycle by echocardiography (3D EPIQ G7 Philips© or similar).
Applanation tonometry
Measurements using the SphygmoCor radial tonometer (AtCor Medical, Pty Ltd, Sydney, Australia), the most widely used tonometer in clinical research for non-invasive central pressure measurement and pulse wave analysis. The central blood pressure is then estimated using a validated radial-aortic transfer function.
The tonometer requires prior calibration by mean (MAP) and diastolic (PAD) blood pressure measured with the conventional brachial cuff as validated in the literature.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Patient who has not signed the consent
* Pregnant woman
* Patient under judicial protection
* Patient without affiliation to a social security scheme
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
INSERM UMR-942, Paris, France
OTHER
M3DISIM
OTHER
Assistance Publique - Hôpitaux de Paris
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Joaquim MATEO, MD
Role: STUDY_DIRECTOR
Assistance Publique - Hôpitaux de Paris
Fabrice VALLEE, MD
Role: PRINCIPAL_INVESTIGATOR
Assistance Publique - Hôpitaux de Paris
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Department of Anesthesiology and Intensive Care, Lariboisière Hospital
Paris, , France
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2018-A02737-48
Identifier Type: OTHER
Identifier Source: secondary_id
APHP180410
Identifier Type: -
Identifier Source: org_study_id
More Related Trials