The Use of a Novel Microbicidal Liquid Polymer for the Reduction of Pin Track Infection

NCT ID: NCT03756506

Last Updated: 2021-03-30

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

13 participants

Study Classification

INTERVENTIONAL

Study Start Date

2018-11-07

Study Completion Date

2019-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of the study is to investigate additional clinical uses for the polymer, which is a FDA approved, 510k, medical device, but has not been approved for use on patients with pin track sites as a way to lower the infection rate and is investigational for this purpose. The approved uses include wound care and post-operative care.

About 13 subjects will take part in this study.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Study Objectives Research participants eligible for the study will be those undergoing Deformity Correction and Traumatic Provisional Fixation. These research participants have a number of pins placed to ensure this required rigid fixation. The number of external fixation pins averages approximately ten per research participant.

It is a 510K FDA cleared medical device indicated for providing a covering over minor wounds and scrapes that are clean and dry. The microbicidal liquid solution consists of organic polymer dissolved in methylene chloride organic solvent. The unique formulation eradicates any organisms (bacteria, fungi, viruses) it comes in contact with. This is a result of the methylene chloride's activity against an infinite number of organisms. The methylene chloride evaporates leaving a clear, elastomeric, non-odorous film for covering minor wounds. The film protects the wound against entry of water, dirt, and germs. The film is elastomeric and protects in difficult regions where flexing, bending and creasing skin occurs. The clear film forms in less than a minute. Application is commonly accomplished using a cotton tip applicator. The liquid is applied on and around the wound extending at least an inch and a quarter beyond the edges of the wound. Momentary stinging may occur upon initial application. The film commonly remains intact for one to three days or longer depending on exposure to rubbing, flexing, or soap and water. This film is resistant to degradation by water alone, but can be easily removed with the combination of soap and water or it can be gently peeled off starting at the outer edges. It is for external use only. It is not intended for use on deep or infected wounds or puncture wounds, or for use near the eyes, mouth, or nose. Intentional inhaling of the contents may be harmful or fatal. The bottle should be tightly capped after each use to prevent evaporation of the solvent.7

This Principle Investigator has previously utilized and topically applied the product as an additional step in the treatment protocol for pin site care for several reconstructive surgery patients (approximately 25) with over 200 pin sites with only 2 pin site infections. This represents a significant reduction from the average incidence of pin site infections reported in the literature (\<1% vs 27% on a per research participant basis). A recently published retrospective case series evaluating this microbicidal polymer dressing reported 6 patients and 66 pins had no infections when Duraderm® was used as part of their pin site care regimen.8

This study was undertaken to formally evaluate whether this microbial liquid po used on pin sites leads to a reduction in pin track infections when compared to a control group as well as the reported average incidence in the literature.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Infection Post-operative Care

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

The study will enroll 12 total research participants (6 control research participants and 6 research participants) with approximately 120 pin sites (approximately 60 in the Control group and 60 in the DuraDerm® group). Each research participant undergoing Deformity Correction and/or Traumatic Provisional Surgery will be asked to participate in the study to evaluate if the topical application of a Novel Microbicidal Liquid Polymer as an additional step in the management of post-operative pin track site care reduces the incidence of pin track infections. Investigational Review Board (IRB) approval will be obtained and informed research participant consent will be obtained from each research participant.
Primary Study Purpose

PREVENTION

Blinding Strategy

SINGLE

Caregivers

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Novel Microbicidal Liquid Polymer

All pins and wire sites will be cleaned daily while hospitalized. Basic pin care will be performed once daily by hospital nursing staff prior to discharge. Following discharge from the hospital, the pin care protocol will be continued by research participant's caregiver.Research participants will be instructed to notify the Principal Investigator if they observe any signs or symptoms of infection. These include redness around pin site, discharge,tenderness in the soft tissue, loosening of the pin, nausea, vomiting, fever or chills.

Step 1: Brush the pin sites with saline using an ordinary soft toothbrush or gauze with sterile gloves Step 2: If following Step 1, debris remains, use forceps (tweezers) to gently remove debris. Step 3: Apply product with Q-tip on clean dry wound around (extending approximately one inch around pin site) and on the pin. The Polymer will be applied daily while in the hospital and then at a minimum of at least three times a week until pin removal.

Group Type ACTIVE_COMPARATOR

Novel Microbicidal Liquid Polymer

Intervention Type DEVICE

The polymer is a 510K FDA cleared medical device indicated for providing a covering over minor wounds and scrapes that are clean and dry. The microbicidal liquid solution consists of organic polymers . The unique formulation eradicates any organisms (bacteria, fungi, viruses) it comes in contact with. This is a result of the solvent's activity against an infinite number of organisms After eradication is complete, the solvent then transitions into a clear, elastomeric, non-odorous film for covering disrupted tissue. The film protects the wound against entry of water, dirt, and germs. The film is elastomeric and protects in difficult regions where flexing, bending and creasing skin occurs. The clear film forms in less than a minute.6 DuraDerm® should not be used to the treat deep infected wounds. DuraDerm® can be used to protect disrupted skin surface of wounds that are clean and dry.

Control group: no Novel Microbicidal Liquid Polymer

The usual care of pin track sites will be followed as outlined belowAll pins and wire sites will be cleaned daily while hospitalized. Basic pin care will be performed once daily by hospital nursing staff prior to discharge. Following discharge from the hospital, the pin care protocol will be continued by research participant's caregiver.

Research participants will be instructed to notify the Principal Investigator if they observe any signs or symptoms of infection. These include redness around pin site, discharge, tenderness in the soft tissue, loosening of the pin, nausea, vomiting, fever or chills.

Research participants will be instructed that the approach to pin care should occur in a step-wise fashion. Step 1: Brush the pin sites with saline using an ordinary soft toothbrush or gauze with sterile gloves Step 2: If following Step 1, debris remains, use forceps (tweezers) to gently remove debris.

Group Type NO_INTERVENTION

No interventions assigned to this group

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Novel Microbicidal Liquid Polymer

The polymer is a 510K FDA cleared medical device indicated for providing a covering over minor wounds and scrapes that are clean and dry. The microbicidal liquid solution consists of organic polymers . The unique formulation eradicates any organisms (bacteria, fungi, viruses) it comes in contact with. This is a result of the solvent's activity against an infinite number of organisms After eradication is complete, the solvent then transitions into a clear, elastomeric, non-odorous film for covering disrupted tissue. The film protects the wound against entry of water, dirt, and germs. The film is elastomeric and protects in difficult regions where flexing, bending and creasing skin occurs. The clear film forms in less than a minute.6 DuraDerm® should not be used to the treat deep infected wounds. DuraDerm® can be used to protect disrupted skin surface of wounds that are clean and dry.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Deformity correction, traumatic provisional fixation
2. All pin sites are stable
3. 18 years of age or greater
4. No known contraindication to receive product

Exclusion Criteria

1. Age less than 18 years
2. Known allergy to Methylene Chloride
3. Known sensitivity to organic polymers
4. Non-clean, dry wound at pin
5. Vulnerable research participants (Institutionalized, students, employees, prisoners, or those with decisional incapacity, etc.)
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Prevent-Plus LLC

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Shital Pema, DPM

Role: PRINCIPAL_INVESTIGATOR

Kettering Health System

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Julie Morris

St Louis, Missouri, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol

View Document

Document Type: Statistical Analysis Plan

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2018-01

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Plug Arterial Closure System (PACS, 7F)
NCT00533156 COMPLETED PHASE2