Endorectal Three-dimensional Ultrasound in the Diagnosis of Cryptogenic Fistulas of the Rectum.
NCT ID: NCT03743701
Last Updated: 2018-11-16
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
150 participants
INTERVENTIONAL
2017-12-30
2020-08-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Fistulectomy and Primary Sphincter rEconstruction vs. endorectaL Advancement Flap in the Treatment of High Anal Fistulas
NCT04119700
Diagnostic Value of Recto-perineal Ultrasound in Perianal Fistula
NCT06314945
Anal Sphincter Reconstruction After High Recurrent Anorectal Fistula Excision
NCT04357210
Effects of High-Intensity Focused Ultrasound (HIFU) Treatment on Fecal Continence and Anorretal Fisiology
NCT03289221
Ligation of Intersphincteric Fistula Tract (LIFT) Versus LIFT-plug Procedure for Anal Fistula Repair
NCT01478139
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Transrectal ultrasound in В-mode
The method of transrectal ultrasound in В-mode
A linear transrectal ultrasonic sensor with a frequency of 9 MHz is inserted into the rectum lumen to a depth of 10 cm from the edge of the anus. In real time, the rectal wall and anatomical structures of the anal canal are evaluated using linear sections. The localization of the internal fistula opening, the course of the fistula relative to the fibers of the external sphincter and the presence or absence of cellular and wall plug is determined.
Transrectal ultrasound examination using three-di
The method of transrectal ultrasound examination using three-dimensional image reconstruction.
A mechanical circular transrectal ultrasonic sensor with a frequency of 13 MHz is inserted into the rectum lumen to a depth of 10 cm from the edge of the anus. Within 30 seconds with a scan interval of 2 mm with a length of 10 cm, a circular recording of the anatomical structures of the rectum, surrounding tissue and anal canal takes place, obtaining an array of images in the form of a cube. The study was completed. After, at a convenient time for the researcher is working with a three-dimensional array of images. The resulting cube can be rotated 360 degrees in a circle of its axis, work with the sagittal, frontal and axial plane. To obtain a more visual representation of the exact localization of the internal fistula orifice, the course of the fistula relative to the fibers of the outer sphincter and to design volumetric cellular and wall plug.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
The method of transrectal ultrasound in В-mode
A linear transrectal ultrasonic sensor with a frequency of 9 MHz is inserted into the rectum lumen to a depth of 10 cm from the edge of the anus. In real time, the rectal wall and anatomical structures of the anal canal are evaluated using linear sections. The localization of the internal fistula opening, the course of the fistula relative to the fibers of the external sphincter and the presence or absence of cellular and wall plug is determined.
The method of transrectal ultrasound examination using three-dimensional image reconstruction.
A mechanical circular transrectal ultrasonic sensor with a frequency of 13 MHz is inserted into the rectum lumen to a depth of 10 cm from the edge of the anus. Within 30 seconds with a scan interval of 2 mm with a length of 10 cm, a circular recording of the anatomical structures of the rectum, surrounding tissue and anal canal takes place, obtaining an array of images in the form of a cube. The study was completed. After, at a convenient time for the researcher is working with a three-dimensional array of images. The resulting cube can be rotated 360 degrees in a circle of its axis, work with the sagittal, frontal and axial plane. To obtain a more visual representation of the exact localization of the internal fistula orifice, the course of the fistula relative to the fibers of the outer sphincter and to design volumetric cellular and wall plug.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patients diagnosed with cryptogenic fistulas
* Patients who have signed informed consent
Exclusion Criteria
* Рatients with post-traumatic fistulas
* Рatients with fistulas, drain pararectal cysts
* Рatients with anal fissures, complicated by rectal fistula
* Рatients who refused to participate in the study of their own free will
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
State Scientific Centre of Coloproctology, Russian Federation
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
State Sceintific Centtre of Coloproctology
Moscow, , Russia
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
82
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.