Cataract Surgery Combined With Endoscopic Goniosynechialysis for Advanced Primary Angle Closure Glaucoma
NCT ID: NCT03686072
Last Updated: 2018-09-26
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
19 participants
INTERVENTIONAL
2014-02-28
2017-10-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Inclusion and exclusion criteria Inclusion criteria included: a diagnosis of PACG according to the International Society of Geographical \& Epidemiological Ophthalmology (ISGEO) diagnostic criteria,14 visual field score ≥18 calculated (as per the method used in the Advanced Glaucoma Intervention Study \[AGIS\]),15 treatment with IOP-lowering drugs for more than 3 months, and mild to moderate cataract. Exclusion criteria included: secondary angle-closure glaucoma and previous history of surgery, except laser peripheral iridotomy.
Preoperative and postoperative examinations Preoperative examinations included: best corrected logMAR visual acuity (BCVA), number of intraocular pressure (IOP) lowering drugs, slit lamp and fundus examination, gonioscopy, Goldmann applanation tonometry and ultrasound biomicroscopy (UBM). Visual field tests were conducted with a Humphrey Visual Field Analyzer II.
All patients were reviewed at 1 week, 1 month, 3 months, 6 months and 12 months after surgery. The number of IOP-lowering drugs and IOP was observed and recorded at each follow-up. The extent of peripheral anterior synechiae , the BCVA and the visual field were recorded at 12 months following surgery.
Surgery procedure All patients used IOP-lowering drugs before surgery; IOP was controlled under 21mmHg where possible. If the preoperative IOP was over 40mmHg a preoperative anterior chamber paracentesis was performed. All surgeries were performed by the same experienced surgeon (WP). Intraoperative and postoperative complications were recorded.
In all patients, phacoemulsification was performed first. After implantation of the IOL, an ophthalmic endoscope (OE) probe was inserted into the anterior chamber to visualize the PAS through the main incision and side incision. A viscoelastic agent was injected towards the root of the iris where PAS existed. Then a blunt iris spatula was used to release the areas where PAS remained under direct view with the OE. Complete synechialysis was confirmed under the direct view with the OE at the end of the procedure.
Success criteria Based on the AGIS study, we defined surgical success as follows: (1) Standard A: IOP\<14mmHg using none or one type of IOP-lowering drug; (2) Standard B: IOP \<18mmHg using none or one type of IOP-lowering drug.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of Phacotrabeculectomy and Trabeculectomy in the Treatment of Primary Angle-closure Glaucoma (PACG)
NCT01298635
Electroretinogram and Retinal Vascular Changes After Cataract Surgery
NCT05871034
Trabeculectomy Versus Peripheral Iridectomy Plus Goniotomy in Advanced PACG
NCT05163951
Comparation of CLASS Combined With Phacoemulsification and CLASS Alone in the Treatment of Primary Open Angle Glaucoma
NCT04920227
Phacotrabeculectomy Versus Phacogoniotomy (PVP) in Advanced Primary Angle-closure Glaucoma
NCT04878458
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
In recent years cataract surgery (phacoemulsification with intraocular lens implantation) combined with goniosynechialysis (Phaco-IOL-GSL) has become more widely used in the treatment of PACG.8-11 Compared with the classic glaucoma filtration surgery, Phaco-IOL-GSL does not involve the creation of a filtering bleb with the need for long-term close follow-up. This is important for patients with poor compliance or difficulty with travel. However, the efficacy and risk of Phaco-IOL-GSL in patients with advanced glaucoma has not been reported. We prospectively performed phacoemulsification combined with intraocular lens implantation combined with endoscopic goniosynechialysis (Phaco-IOL-EGSL) in patients with advanced angle-closure glaucoma, and explored the efficacy and risk of the surgery.
Materials and methods Subjects Our objective was to measure the extent of PAS, number of intraocular pressure(IOP) lowering drugs, IOP, BCVA and visual field before and after surgery in patients with advanced PACG, to investigate the efficacy and safety of Phaco-IOL-EGSL. We also evaluate the correlation between the two groups of data.
In this prospective study, consecutive patients with advanced PACG and cataract who underwent Phaco-IOL-EGSL were invited to participate. The study was approved by the Ethics Committee of the Affiliated Eye Hospital of Wenzhou Medical University and informed consent was obtained from all patients, adhered to the tenets of the Declaration of Helsinki. All patients were treated at the Affiliated Eye Hospital of Wenzhou Medical University between February 2014 and March 2016. A total of 17 subjects (19 eyes) were enrolled in the study. Patients were followed up for 12 months. One patient was lost during follow-up, and 16 subjects (18 eyes) were analyzed in this study. No patient refused to participate in the study.
Inclusion and exclusion criteria Inclusion criteria included: a diagnosis of PACG according to the International Society of Geographical \& Epidemiological Ophthalmology (ISGEO) diagnostic criteria,14 visual field score ≥18 calculated (as per the method used in the Advanced Glaucoma Intervention Study \[AGIS\]), treatment with IOP-lowering drugs for more than 3 months, and mild to moderate cataract. Exclusion criteria included: secondary angle-closure glaucoma and previous history of surgery, except laser peripheral iridotomy.
Preoperative and postoperative examinations Preoperative examinations included: best corrected logMAR visual acuity (BCVA), number of intraocular pressure (IOP) lowering drugs, slit lamp and fundus examination, gonioscopy, Goldmann applanation tonometry and ultrasound biomicroscopy (UBM) (Suowei, Tianjin, China). Visual field tests were conducted with a Humphrey Visual Field Analyzer II (central 30-2 threshold test, size III white stimulus, and SITA-FAST strategy, with the foveal threshold test turned on).
Gonioscopy was performed in a dark room by the same experienced glaucoma specialist (WP) using a Zeiss-style 4-mirror lens (Zeiss Corp, Germany). The examination start with the inferior angle by looking through the superior mirror, the corneal wedge is used to orient oneself to the anatomy.16 The extent of PAS was evaluated by performing indentation gonioscopy around the entire circumference of angle.
All patients were reviewed at 1 week, 1 month, 3 months, 6 months and 12 months after surgery. The number of IOP-lowering drugs and IOP was observed and recorded at each follow-up. The extent of peripheral anterior synechiae , the BCVA and the visual field were recorded at 12 months following surgery.
Surgery procedure All patients used IOP-lowering drugs before surgery; IOP was controlled under 21mmHg where possible. If the preoperative IOP was over 40mmHg a preoperative anterior chamber paracentesis was performed. All surgeries were performed by the same experienced surgeon (WP). Intraoperative and postoperative complications were recorded.
Anaesthesia consisted of topical 0.5% proparacaine and a peribulbar block with bupivacaine. Then conventional phacoemulsification and IOL implantation (CT ASPHINA 509M, Zeiss Corp.) were performed. In all patients, phacoemulsification was performed using the following fluidic parameters: bottle height between 70 and 90 cm, a fixed aspiration flow rate (AFR) of 20 cc/min, and vacuum settings up to 350 mmHg, depending on the grade of nuclear sclerosis. Immediately after implantation of the IOL, a 23G ophthalmic endoscope (OE) probe (URAM E2, USA ENDO OPTIKS) was inserted into the anterior chamber to visualize the PAS through the main incision and side incision. A viscoelastic agent was injected towards the root of the iris where PAS existed (Figure 1A). Then a blunt iris spatula was used to release the areas where PAS remained. The tip was gently moved anteroposterior near the root of the iris in either a clockwise or a counterclockwise direction to release PAS under direct view with the OE (Figure 1B). Both the main incision and a second incision were used to ensure all PAS areas were released. Complete synechialysis was confirmed under the direct view with the OE at the end of the procedure. Using an irrigation and aspiration handpiece from the phaco machine, balanced salt solution replaced the viscoelastic agent. The incision was closed by hydration or sutured with 10-0 nylon if necessary.
Patients used Pranoprofen eye drops (Senju Pharmaceutical Co., Ltd., Japan) and Levofloxacin eye drops (Santen, Japan) four times a day and 0.5% pilocarpine eyedrops (Bausch \& Lomb, America) two times a day for four weeks after the surgery. Patients also used 1% prednisolone acetate eye drops (Allergan Pharmaceuticals, Ireland) four times a day for the first week after the surgery, and then reduced by one drop per week for a total of four weeks.
Success criteria Based on the AGIS study, we defined surgical success as follows: (1) Standard A: IOP\<14mmHg using none or one type of IOP-lowering drug; (2) Standard B: IOP \<18mmHg using none or one type of IOP-lowering drug.17 Statistical analysis All statistical analyses were performed using SPSS 20.0 statistical software. All data were represented by mean ± standard deviation (SD). The paired t-test was used to evaluate the differences in the extent of PAS, number of IOP lowering drugs, mean deviation , IOP and BCVA. A Spearman rank correlation coefficient was calculated to evaluate the correlation between the two groups of data.18 Statistical significance was set with a P-value \<0.05.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Cataract surgery with goniosynechialysis
Cataract surgery with endoscopic goniosynechialysis
Phacoemulsification was performed first. Immediately after implantation of the IOL, a 23G ophthalmic endoscope (OE) probe was inserted into the anterior chamber to visualize the PAS through the main incision and side incision. A viscoelastic agent and a blunt iris spatula were used to release the areas where where PAS existed.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Cataract surgery with endoscopic goniosynechialysis
Phacoemulsification was performed first. Immediately after implantation of the IOL, a 23G ophthalmic endoscope (OE) probe was inserted into the anterior chamber to visualize the PAS through the main incision and side incision. A viscoelastic agent and a blunt iris spatula were used to release the areas where where PAS existed.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Wenzhou Medical University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
yin ying zhao
Department of Catract
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
QZB-HZ-PHACO-EGSL
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.