PSG Validation of MATRx Plus AHI

NCT ID: NCT03627169

Last Updated: 2021-03-04

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

34 participants

Study Classification

OBSERVATIONAL

Study Start Date

2017-07-25

Study Completion Date

2019-07-03

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Obstructive sleep apnea (OSA) is a common disease that carries significant risks for cardiovascular disease, mortality, and economic costs. Almost thirty years ago, initial population studies found the prevalence of OSA to be five to nine percent of the adult population. Excess body weight is a risk factor for the development of OSA, and the recent rise in prevalence of obesity has led to revised estimates of OSA prevalence, now at seventeen per cent of the adult population. OSA is poorly recognized clinically; 85% of apneics remain undiagnosed and untreated.

Currently, the diagnosis of OSA commonly relies on an overnight, in-hospital polysomnogram (PSG). Due to the extensive attachments to the body surface required in a PSG, it has developed a negative impression. Any effective solution to the public health challenges posed by sleep apnea will have to consider the need for less cumbersome and off-putting methods.

Zephyr Sleep Technologies has developed a device that has been approved for use in Canada. The MATRx plus device functions as both a Level III sleep recorder (records respiratory airflow, respiratory effort, pulse rate, and arterial oxygen saturation) as well as a home-based system to select patients for oral appliance therapy. The American Academy of Sleep Medicine (AASM) recommends the use of apnea-hypopnea index (AHI) for the diagnosis and categorization of OSA severity. The Level III function of the MATRx plus device is approved for use in Canada with two autoscoring methods: oxygen desaturation index, ODI and apnea-hypopnea index, AHI, but requires further validation of AHI for clearance by the US Food and Drug Administration (FDA).

The proposed research will validate the AHI autoscoring function of the MATRs plus Level III home sleep recorder by comparing it to data recorded in a PSG, which is considered to be the gold standard for sleep testing. Though the effectiveness of the AHI autoscoring algorithm has been previously established, it has not been validated against PSG data. Additionally, other parameters such as snoring will be examined in order to develop scoring algorithms for other facets of sleep disordered breathing.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Obstructive sleep apnea (OSA) is a common disease that carries significant risks for cardiovascular disease, mortality, and economic costs. Almost thirty years ago, initial population studies found the prevalence of OSA to be five to nine percent of the adult population. Excess body weight is a risk factor for the development of OSA, and the recent rise in prevalence of obesity has led to revised estimates of OSA prevalence, now at seventeen per cent of the adult population. OSA is poorly recognized clinically; 85% of apneics remain undiagnosed and untreated.

OSA derives fundamentally from structural abnormalities of the pharynx that cause pharyngeal narrowing or closure during sleep and produce recurrent apneas and hypopneas. During wakefulness, compensatory neuromuscular reflexes protect the pharynx from collapse. These reflexes are lost during sleep, leaving the collapsible human pharynx susceptible to narrowing or closure. Owing largely to its association with excess body weight, OSA has arguably become the most prevalent chronic non-communicable disease in industrialized societies, assuming that obesity is not classified a disease. In addition to impairing quality of life, OSA conveys an increased risk of cardiovascular disease and vehicular accidents. The majority of apneics remain undiagnosed and untreated. Thus, OSA has the hallmarks of a major public health problem, affecting all age groups and increasing in epidemic proportions. Unfortunately, current medical practices seem ill-suited to dealing with the challenges posed by OSA.

Perhaps the most unsettling aspect of present medical practices relates to the cumbersome, uninviting, and expensive methods currently used to diagnose the disease. Common clinical experience indicates that individuals often resist undergoing the standard diagnostic test, an overnight in-hospital polysomnogram (PSG), because of the extensive attachments to the body surface. In other words, as public awareness of sleep apnea has increased so also has the negative impression of current testing. Any effective solution to the public health challenges posed by sleep apnea will have to consider the need for less cumbersome and off-putting clinical methods.

Zephyr Sleep Technologies has developed a device that has been approved for use in Canada. The device, MATRx plus, functions as both a Level III sleep recorder (records respiratory airflow, respiratory effort, pulse rate, and arterial oxygen saturation) as well as a home-based system to select patients for oral appliance therapy. The American Academy of Sleep Medicine (AASM) recommends the use of apnea-hypopnea index (AHI) for the diagnosis and categorization of OSA severity. The Level III function of the MATRx plus device is approved for use in Canada with two autoscoring methods: oxygen desaturation index, ODI and apnea-hypopnea index, AHI, but requires further validation of AHI for clearance by the US Food and Drug Administration (FDA).

The proposed research will validate the AHI autoscoring function of the MATRs plus Level III home sleep recorder by comparing it to data recorded in a PSG, which is considered to be the gold standard for sleep testing. Though the effectiveness of the AHI autoscoring algorithm has been previously established, it has not been validated against PSG data. Additionally, other parameters such as snoring will be examined in order to develop scoring algorithms for other facets of sleep disordered breathing.

Once the participant arrives at the PSG laboratory, the clinical coordinator will obtain written informed consent, review inclusion and exclusion criteria, and enroll eligible participants into the study. The clinical coordinator will give the participant a brief overview on use of the MATRx plus Level III sleep recorder, then return to the control room to watch the participant set up the device via video. The participant will be made aware of the video recorded during set up the MATRx plus device. The device set up consists of: dual nares nasal cannula for airflow, respiratory effort belt, pulse oximeter, snoring (recorded via airflow frequency on the nasal cannula and via sound on the tablet), body position from an accelerometer built into the body-worn recorder. The sleep technician will then set the participant up with a standard PSG montage, consisting of: electroencephalogram (EEG), electrooculogram (EOG), electromyogram (EMG), pulse oximeter, nasal cannula, two respiratory effort belts, snoring, and body position (recorded via body-mounted accelerometer). Once the participant has both the MATRx plus and the PSG montage set up, the study will commence, and the participant will be monitored by video from the PSG control room, as is standard practice in a PSG. The sleep technician will intervene as necessary to ensure adequate signals are collected by the PSG equipment.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Obstructive Sleep Apnea

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

MATRx plus/PSG group

Healthy individuals, individuals suspected of having OSA, and individuals with a previous diagnosis of OSA will spend a single night in a sleep laboratory and undergo a standard polysomnogram simultaneously with a Level III sleep study using the MATRx plus device. There is no interventional aspect to the study.

MATRx plus

Intervention Type DEVICE

The MATRx plus device will be used in its capacity as a Level III home sleep apnea test (HSAT). Note: MATRx plus is approved for use in Canada; therefore, the study does not involve any investigational devices.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

MATRx plus

The MATRx plus device will be used in its capacity as a Level III home sleep apnea test (HSAT). Note: MATRx plus is approved for use in Canada; therefore, the study does not involve any investigational devices.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Aged between 21 and 80 years
* Ability to understand and provide informed consent
* Ability and willingness to meet the required schedule

Exclusion Criteria

* Inability to breathe comfortably through the nose
* Symptomatic, non-respiratory sleep disorder, e.g., restless leg syndrome, chronic insomnia
* Heart failure
* Cerebral vascular incident within the last 12 months
* Use of pacemaker or other life-supporting device
Minimum Eligible Age

21 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Zephyr Sleep Technologies

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Zephyr Sleep Technologies

Calgary, Alberta, Canada

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Canada

References

Explore related publications, articles, or registry entries linked to this study.

Topor ZL, Remmers JE, Grosse J, Mosca EV, Jahromi SAZ, Zhu Y, Bruehlmann S. Validation of a new unattended sleep apnea monitor using two methods for the identification of hypopneas. J Clin Sleep Med. 2020 May 15;16(5):695-703. doi: 10.5664/jcsm.8324. Epub 2020 Feb 6.

Reference Type DERIVED
PMID: 32024586 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

ZCP201704

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Effectiveness of NOA OATMAD
NCT07111962 NOT_YET_RECRUITING