Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
34 participants
OBSERVATIONAL
2017-07-25
2019-07-03
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Currently, the diagnosis of OSA commonly relies on an overnight, in-hospital polysomnogram (PSG). Due to the extensive attachments to the body surface required in a PSG, it has developed a negative impression. Any effective solution to the public health challenges posed by sleep apnea will have to consider the need for less cumbersome and off-putting methods.
Zephyr Sleep Technologies has developed a device that has been approved for use in Canada. The MATRx plus device functions as both a Level III sleep recorder (records respiratory airflow, respiratory effort, pulse rate, and arterial oxygen saturation) as well as a home-based system to select patients for oral appliance therapy. The American Academy of Sleep Medicine (AASM) recommends the use of apnea-hypopnea index (AHI) for the diagnosis and categorization of OSA severity. The Level III function of the MATRx plus device is approved for use in Canada with two autoscoring methods: oxygen desaturation index, ODI and apnea-hypopnea index, AHI, but requires further validation of AHI for clearance by the US Food and Drug Administration (FDA).
The proposed research will validate the AHI autoscoring function of the MATRs plus Level III home sleep recorder by comparing it to data recorded in a PSG, which is considered to be the gold standard for sleep testing. Though the effectiveness of the AHI autoscoring algorithm has been previously established, it has not been validated against PSG data. Additionally, other parameters such as snoring will be examined in order to develop scoring algorithms for other facets of sleep disordered breathing.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Validation of a Simplified MATRx Plus
NCT03812692
Predictive Accuracy of MATRx Plus in Identifying Favorable Candidates for Oral Appliance Therapy
NCT03217383
Improving the Efficiency of the Digital Sleep Workflow Using MATRx Plus
NCT03579225
The Effect of Mandibular Advancement Devices on Markers of Cardiovascular Health in Obstructive Sleep Apnea Patients
NCT05387122
Validation of a Novel Device for Screening Patients With Symptoms of Obstructive Sleep Apnea
NCT04121923
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
OSA derives fundamentally from structural abnormalities of the pharynx that cause pharyngeal narrowing or closure during sleep and produce recurrent apneas and hypopneas. During wakefulness, compensatory neuromuscular reflexes protect the pharynx from collapse. These reflexes are lost during sleep, leaving the collapsible human pharynx susceptible to narrowing or closure. Owing largely to its association with excess body weight, OSA has arguably become the most prevalent chronic non-communicable disease in industrialized societies, assuming that obesity is not classified a disease. In addition to impairing quality of life, OSA conveys an increased risk of cardiovascular disease and vehicular accidents. The majority of apneics remain undiagnosed and untreated. Thus, OSA has the hallmarks of a major public health problem, affecting all age groups and increasing in epidemic proportions. Unfortunately, current medical practices seem ill-suited to dealing with the challenges posed by OSA.
Perhaps the most unsettling aspect of present medical practices relates to the cumbersome, uninviting, and expensive methods currently used to diagnose the disease. Common clinical experience indicates that individuals often resist undergoing the standard diagnostic test, an overnight in-hospital polysomnogram (PSG), because of the extensive attachments to the body surface. In other words, as public awareness of sleep apnea has increased so also has the negative impression of current testing. Any effective solution to the public health challenges posed by sleep apnea will have to consider the need for less cumbersome and off-putting clinical methods.
Zephyr Sleep Technologies has developed a device that has been approved for use in Canada. The device, MATRx plus, functions as both a Level III sleep recorder (records respiratory airflow, respiratory effort, pulse rate, and arterial oxygen saturation) as well as a home-based system to select patients for oral appliance therapy. The American Academy of Sleep Medicine (AASM) recommends the use of apnea-hypopnea index (AHI) for the diagnosis and categorization of OSA severity. The Level III function of the MATRx plus device is approved for use in Canada with two autoscoring methods: oxygen desaturation index, ODI and apnea-hypopnea index, AHI, but requires further validation of AHI for clearance by the US Food and Drug Administration (FDA).
The proposed research will validate the AHI autoscoring function of the MATRs plus Level III home sleep recorder by comparing it to data recorded in a PSG, which is considered to be the gold standard for sleep testing. Though the effectiveness of the AHI autoscoring algorithm has been previously established, it has not been validated against PSG data. Additionally, other parameters such as snoring will be examined in order to develop scoring algorithms for other facets of sleep disordered breathing.
Once the participant arrives at the PSG laboratory, the clinical coordinator will obtain written informed consent, review inclusion and exclusion criteria, and enroll eligible participants into the study. The clinical coordinator will give the participant a brief overview on use of the MATRx plus Level III sleep recorder, then return to the control room to watch the participant set up the device via video. The participant will be made aware of the video recorded during set up the MATRx plus device. The device set up consists of: dual nares nasal cannula for airflow, respiratory effort belt, pulse oximeter, snoring (recorded via airflow frequency on the nasal cannula and via sound on the tablet), body position from an accelerometer built into the body-worn recorder. The sleep technician will then set the participant up with a standard PSG montage, consisting of: electroencephalogram (EEG), electrooculogram (EOG), electromyogram (EMG), pulse oximeter, nasal cannula, two respiratory effort belts, snoring, and body position (recorded via body-mounted accelerometer). Once the participant has both the MATRx plus and the PSG montage set up, the study will commence, and the participant will be monitored by video from the PSG control room, as is standard practice in a PSG. The sleep technician will intervene as necessary to ensure adequate signals are collected by the PSG equipment.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
MATRx plus/PSG group
Healthy individuals, individuals suspected of having OSA, and individuals with a previous diagnosis of OSA will spend a single night in a sleep laboratory and undergo a standard polysomnogram simultaneously with a Level III sleep study using the MATRx plus device. There is no interventional aspect to the study.
MATRx plus
The MATRx plus device will be used in its capacity as a Level III home sleep apnea test (HSAT). Note: MATRx plus is approved for use in Canada; therefore, the study does not involve any investigational devices.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
MATRx plus
The MATRx plus device will be used in its capacity as a Level III home sleep apnea test (HSAT). Note: MATRx plus is approved for use in Canada; therefore, the study does not involve any investigational devices.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Ability to understand and provide informed consent
* Ability and willingness to meet the required schedule
Exclusion Criteria
* Symptomatic, non-respiratory sleep disorder, e.g., restless leg syndrome, chronic insomnia
* Heart failure
* Cerebral vascular incident within the last 12 months
* Use of pacemaker or other life-supporting device
21 Years
80 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Zephyr Sleep Technologies
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Zephyr Sleep Technologies
Calgary, Alberta, Canada
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Topor ZL, Remmers JE, Grosse J, Mosca EV, Jahromi SAZ, Zhu Y, Bruehlmann S. Validation of a new unattended sleep apnea monitor using two methods for the identification of hypopneas. J Clin Sleep Med. 2020 May 15;16(5):695-703. doi: 10.5664/jcsm.8324. Epub 2020 Feb 6.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ZCP201704
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.