Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
TERMINATED
100 participants
OBSERVATIONAL
2018-10-17
2022-08-11
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Registry and Survey of Women With Pregnancy Related Cardiomyopathy
NCT00273637
The Heart Outcomes in Pregnancy Expectations for Mom and Baby Study
NCT06517628
A Study of Pregnancy Outcomes in Congenital Heart Disease
NCT06678256
Evaluation Cardiac Function With Echo and BNP in Obstetrical Patients With/Without Cardiac Disease
NCT00759733
Congenital Heart Anomaly Risk in Maternal Enteroviral Infection and Diabetes
NCT04769167
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Following delivery, many of these cardiovascular changes reverse in the first 2 weeks postpartum with further normalization toward preconception values 3-12 months later. Women without heart disease adapt well and adverse events are generally rare. However, the stress induced by these antenatal changes can cause a patient with underlying disease to decompensate during the latter half of pregnancy and more specifically, intrapartum when these changes peak. Studies on maternal morbidity attributable to cardiac disease in the United States have shown the most likely time for an adverse cardiac event is intrapartum and immediately postpartum, owing to the drastic and acute changes in hemodynamic status during these time periods. Without an invasive monitor (PAC), hemodynamic monitoring during these time relies on surrogate markers such as blood pressure or heart rate.
There is relatively scarce data on continuous hemodynamic profiles in women with both congenital and acquired heart disease in pregnancy, specifically during labor. Previous literature on the use of invasive monitoring (PAC) during pregnancy have been performed only intermittently during the labor and postpartum process. However, the hemodynamic status during the second and third labor stages is not static and therefore the need for continuous evaluation cannot be underscored.
The increased morbidity associated with invasive monitoring limits the use of pulmonary artery catheters in the pregnant population and therefore a non-invasive way to obtain hemodynamic profiles in women with heart disease is desirable. The non-invasive cardiac output monitor (NICOM) is based on bio-reactance technology and is operator-independent, allowing negligible inter-observer variability in data collection and ease of use. Measurements of cardiac output and stroke volume are not dependent on the distance between the electrodes, which can significantly increase the accuracy of the results. It involves the application of four sensors on the thorax. Changes in aortic blood flow drive phase shifts of propagating waves which are detected by the sensors as the frequency changes. These changes correlate with instantaneous changes in blood volume and blood flow in the aorta. Bio-reactance has been validated against pulmonary artery catheters in non-pregnant populations which manifest various forms of hemodynamic instability and following cardiac surgery.
Transthoracic bio-reactance, or the non-invasive cardiac output measurement \[NICOMTM, Cheetah Medical Inc., Portland, OR\] system, is a new technique that is able to measure multiple hemodynamic parameters with four transdermal electrodes placed on the patients' thorax. It is based on frequency- and phase-modulation of the voltage signal measured in response to an applied transthoracic current. Its readings have been shown in multiple studies to correlate well with PAC in the non-pregnant population. It has shown acceptable accuracy, precision and responsiveness for cardiac output monitoring in patients experiencing a wide-range of hemodynamic situations. However, it has not been validated in the pregnant, structurally abnormal heart i.e. congenital cardiac disease, as this was exclusion criteria in the aforementioned studies. Establishing normative values during the second stage of labor utilizing the NICOM in women with congenital cardiac disease has the potential to be clinically useful in developing goal-directed management therapy for these women.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_CONTROL
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Heart Disease in pregnancy group
Fifty women will be recruited with structurally and functionally abnormal hearts without a history of chronic hypertension, pre-gestational diabetes, multiple gestations, preeclampsia, autoimmune disease, and anyone with a history of cardiomyopathy but currently normal ejection fraction. Women who are unable to give informed consent will not be included.
NICOM (non-invasive cardiac output monitor)
Transthoracic bio-reactance, or the non-invasive cardiac output measurement \[NICOMTM, Cheetah Medical Inc., Portland, OR\] system, is a new technique that is able to measure multiple hemodynamic parameters with four transdermal electrodes placed on the patients' thorax. It is based on frequency- and phase-modulation of the voltage signal measured in response to an applied transthoracic current. It has shown acceptable accuracy, precision and responsiveness for cardiac output monitoring in patients experiencing a wide-range of hemodynamic situations and is a FDA-approved device.
Control Group
Fifty women will be recruited with structurally normal hearts without a history of chronic hypertension, pre-gestational diabetes, multiple gestations, preeclampsia, autoimmune disease, and anyone with a history of cardiomyopathy but currently normal ejection fraction. Any woman on cardiac or antihypertensive medications (beta blockers, calcium channel blockers, hydralazine) will be excluded. Women who are unable to give informed consent will not be included.
NICOM (non-invasive cardiac output monitor)
Transthoracic bio-reactance, or the non-invasive cardiac output measurement \[NICOMTM, Cheetah Medical Inc., Portland, OR\] system, is a new technique that is able to measure multiple hemodynamic parameters with four transdermal electrodes placed on the patients' thorax. It is based on frequency- and phase-modulation of the voltage signal measured in response to an applied transthoracic current. It has shown acceptable accuracy, precision and responsiveness for cardiac output monitoring in patients experiencing a wide-range of hemodynamic situations and is a FDA-approved device.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
NICOM (non-invasive cardiac output monitor)
Transthoracic bio-reactance, or the non-invasive cardiac output measurement \[NICOMTM, Cheetah Medical Inc., Portland, OR\] system, is a new technique that is able to measure multiple hemodynamic parameters with four transdermal electrodes placed on the patients' thorax. It is based on frequency- and phase-modulation of the voltage signal measured in response to an applied transthoracic current. It has shown acceptable accuracy, precision and responsiveness for cardiac output monitoring in patients experiencing a wide-range of hemodynamic situations and is a FDA-approved device.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* singleton pregnancy
* \> 18 years of age
* enrolled in first trimester of pregnancy
* planning delivery at Saint Luke's Hospital of Kansas City
* STUDY GROUP:
* history of either congenital or acquired heart disease
* singleton pregnancy
* \> 18 years of age
* enrolled in first trimester of pregnancy
* planning delivery at Saint Luke's Hospital of Kansas City
Exclusion Criteria
* no history of either acquired or congenital heart disease
* no hypertension, diabetes, multiple gestations, preeclampsia, or autoimmune disease
* no use of antihypertensive medications
* inability to give informed consent
Study Group:
* no hypertension, diabetes, multiple gestations, preeclampsia, autoimmune disease
* inability to give informed consent
18 Years
FEMALE
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Saint Luke's Health System
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Karen L Florio, DO
Role: PRINCIPAL_INVESTIGATOR
Saint Luke's Hospital of Kansas City/UMKC Assistant Professor, MFM Division
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Saint Luke's Hospital of Kansas City
Kansas City, Missouri, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Canobbio MM, Warnes CA, Aboulhosn J, Connolly HM, Khanna A, Koos BJ, Mital S, Rose C, Silversides C, Stout K; American Heart Association Council on Cardiovascular and Stroke Nursing; Council on Clinical Cardiology; Council on Cardiovascular Disease in the Young; Council on Functional Genomics and Translational Biology; and Council on Quality of Care and Outcomes Research. Management of Pregnancy in Patients With Complex Congenital Heart Disease: A Scientific Statement for Healthcare Professionals From the American Heart Association. Circulation. 2017 Feb 21;135(8):e50-e87. doi: 10.1161/CIR.0000000000000458. Epub 2017 Jan 12.
Velissaris D, Karamouzos V, Kotroni I, Pierrakos C, Karanikolas M. The Use of Pulmonary Artery Catheter in Sepsis Patients: A Literature Review. J Clin Med Res. 2016 Nov;8(11):769-776. doi: 10.14740/jocmr2719w. Epub 2016 Sep 29.
Cornette J, Laker S, Jeffery B, Lombaard H, Alberts A, Rizopoulos D, Roos-Hesselink JW, Pattinson RC. Validation of maternal cardiac output assessed by transthoracic echocardiography against pulmonary artery catheterization in severely ill pregnant women: prospective comparative study and systematic review. Ultrasound Obstet Gynecol. 2017 Jan;49(1):25-31. doi: 10.1002/uog.16015. Epub 2016 Nov 28.
Ohashi Y, Ibrahim H, Furtado L, Kingdom J, Carvalho JC. Non-invasive hemodynamic assessment of non-pregnant, healthy pregnant and preeclamptic women using bioreactance. [corrected]. Rev Bras Anestesiol. 2010 Nov-Dec;60(6):603-13, 335-40. doi: 10.1016/S0034-7094(10)70075-1. English, Portuguese, Spanish.
Keren H, Burkhoff D, Squara P. Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol. 2007 Jul;293(1):H583-9. doi: 10.1152/ajpheart.00195.2007. Epub 2007 Mar 23.
Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C. Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med. 2007 Jul;33(7):1191-1194. doi: 10.1007/s00134-007-0640-0. Epub 2007 Apr 26.
Vinayagam D, Patey O, Thilaganathan B, Khalil A. Cardiac output assessment in pregnancy: comparison of two automated monitors with echocardiography. Ultrasound Obstet Gynecol. 2017 Jan;49(1):32-38. doi: 10.1002/uog.15915.
McLaughlin K, Wright SP, Kingdom JCP, Parker JD. Clinical Validation of Non-Invasive Cardiac Output Monitoring in Healthy Pregnant Women. J Obstet Gynaecol Can. 2017 Nov;39(11):1008-1014. doi: 10.1016/j.jogc.2017.02.015. Epub 2017 Jul 18.
Roberts LA, Ling HZ, Poon LC, Nicolaides KH, Kametas NA. Maternal hemodynamics, fetal biometry and Doppler indices in pregnancies followed up for suspected fetal growth restriction. Ultrasound Obstet Gynecol. 2018 Oct;52(4):507-514. doi: 10.1002/uog.19067.
Sandham JD, Hull RD, Brant RF, Knox L, Pineo GF, Doig CJ, Laporta DP, Viner S, Passerini L, Devitt H, Kirby A, Jacka M; Canadian Critical Care Clinical Trials Group. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med. 2003 Jan 2;348(1):5-14. doi: 10.1056/NEJMoa021108.
Mabie WC, DiSessa TG, Crocker LG, Sibai BM, Arheart KL. A longitudinal study of cardiac output in normal human pregnancy. Am J Obstet Gynecol. 1994 Mar;170(3):849-56. doi: 10.1016/s0002-9378(94)70297-7.
Hunter S, Robson SC. Adaptation of the maternal heart in pregnancy. Br Heart J. 1992 Dec;68(6):540-3. doi: 10.1136/hrt.68.12.540.
Dyer RA, James MF. Maternal hemodynamic monitoring in obstetric anesthesia. Anesthesiology. 2008 Nov;109(5):765-7. doi: 10.1097/ALN.0b013e31818a3825. No abstract available.
Engoren M, Barbee D. Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method. Am J Crit Care. 2005 Jan;14(1):40-5.
Lee W, Rokey R, Cotton DB. Noninvasive maternal stroke volume and cardiac output determinations by pulsed Doppler echocardiography. Am J Obstet Gynecol. 1988 Mar;158(3 Pt 1):505-10. doi: 10.1016/0002-9378(88)90014-2.
Easterling TR, Watts DH, Schmucker BC, Benedetti TJ. Measurement of cardiac output during pregnancy: validation of Doppler technique and clinical observations in preeclampsia. Obstet Gynecol. 1987 Jun;69(6):845-50.
Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999 Feb;15(2):85-91. doi: 10.1023/a:1009982611386.
Doherty A, El-Khuffash A, Monteith C, McSweeney L, Breatnach C, Kent E, Tully E, Malone F, Thornton P. Comparison of bioreactance and echocardiographic non-invasive cardiac output monitoring and myocardial function assessment in primagravida women. Br J Anaesth. 2017 Apr 1;118(4):527-532. doi: 10.1093/bja/aex045.
Vinayagam D, Bowe S, Sheehan E, Thilaganathan B, Khalil A. Non-Invasive Haemodynamic Monitoring in Pregnancy: A Comparative Study Using Ultrasound and Bioreactance. Fetal Diagn Ther. 2017;41(4):273-282. doi: 10.1159/000446650. Epub 2016 Oct 6.
Related Links
Access external resources that provide additional context or updates about the study.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
18-062
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.