Use of a Novel Device for Stretch Relaxation During Mohs Surgery
NCT ID: NCT03586960
Last Updated: 2018-07-16
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
30 participants
INTERVENTIONAL
2018-07-02
2018-09-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Human skin has biomechanical properties that can be harnessed to facilitate closure of larger wounds. Stress-relaxation refers to the natural relaxation exhibited by skin put under a given amount of tension (stress) over time. After a period of stress, the force required to close the wound is reduced. In a porcine skin wound model, there is a 40-60% reduction in stress after twenty minutes of stretch relaxation.
There are several classic methods of delivering this stretch to skin intraoperatively. Most simply, a towel clamp can be used to bring edges together. However, the clamp, which is a sharp stainless steel instrument, can damage tissues. There are also commercial devices such as TopClosure. However, this device is intended for very large wounds with side plates that must be sutured or stapled to patient skin.
The SUTUREGARD device presents a simple method to provide stress to a wound but not damage tissue. The SUTUREGARD device results in significantly lower pressure on the skin when compared with traditional sutures and creates a much greater volume of wound eversion than is possible with a traditional suturing method. Engineering tests performed at OSU showed that a given simple interrupted suture will exert about 30% less pressure on the skin when used performed with the device compared to without the device. With this protection, this creates the corollary that a suture could be safely tied to a greater force with the device than without. In animal testing, the device has been used on porcine wounds for up to 6 weeks, where it showed superior histologic tolerability over traditional sutures.
The investigators have used the device to provide stress-relaxation within our clinic over the past several months and have seen reductions in wound width of about 30% with retention of the device for 30-60 minutes. Wounds exhibit significantly more reduction in width with overnight use. Unlike traditional retention sutures, which damage the skin, the skin appears normal with retention of the device for up to 2 days in our patients. Furthermore, all wounds that have been stress-relaxed with the device have healed without complication.
The investigators plan to study the stress-relaxation created by use of a SUTUREGARD device applied to cutaneous defects for a specified time periods (30, 60 and 90 minutes).
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Surgical Scar Treatment With the Pulsed Dye Laser in Combination With a CO2 Laser
NCT02898350
Gene Expression During Surgical Scar Remodeling by Fractional Photothermolysis
NCT01858038
Post Excision/Mohs Scar Laser Resurfacing
NCT02130297
Use of the Epidermal Micrografts for Wound Healing After Mohs or Excisional Surgery for Skin Cancer
NCT01536444
Dermabrasion in Mohs: Split-Scar Trial
NCT07213921
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
BASIC_SCIENCE
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Experimental Group
Peak tension will be measured with a calibrated force gauge (Series 3 Digital Force Gauge; Mark-10 Corporation; Copiague, NY) until the wound edges touch. A clamp will be used to secure the sutures on top of the device between measurements. At each time point (5, 10 and 30 minutes), the clamps will be loosened and the wound allowed to relax. Photographs and measurements will be taken to document the wound size after stress-reduction. The suture will be re-tensioned while measurements of peak tension (as outlined above) are recorded with the force gauge.
Peak Force Measurement
Force will be measured at 5,10, and 30 minutes
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Peak Force Measurement
Force will be measured at 5,10, and 30 minutes
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Age over 18 years
* Intact skin surrounding wound for at least 2.5 cm
Exclusion Criteria
* Systemically unstable or unwell patient
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Silver Falls Dermatology
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Silver Falls Dermtology
Salem, Oregon, United States
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Saqib NU, Domenick N, Cho JS, Marone L, Leers S, Makaroun MS, Chaer RA. Predictors and outcomes of restenosis following tibial artery endovascular interventions for critical limb ischemia. J Vasc Surg. 2013 Mar;57(3):692-9. doi: 10.1016/j.jvs.2012.08.115. Epub 2013 Jan 23.
Townsend KL, Akeroyd J, Russell DS, Kruzic JJ, Robertson BL, Lear W. Comparing the Tolerability of a Novel Wound Closure Device Using a Porcine Wound Model. Adv Wound Care (New Rochelle). 2018 Jun 1;7(6):177-184. doi: 10.1089/wound.2017.0777.
Topaz M, Carmel NN, Topaz G, Li M, Li YZ. Stress-relaxation and tension relief system for immediate primary closure of large and huge soft tissue defects: an old-new concept: new concept for direct closure of large defects. Medicine (Baltimore). 2014 Dec;93(28):e234. doi: 10.1097/MD.0000000000000234.
Hussain SH, Limthongkul B, Humphreys TR. The biomechanical properties of the skin. Dermatol Surg. 2013 Feb;39(2):193-203. doi: 10.1111/dsu.12095. Epub 2013 Jan 25.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IRB18-025
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.