Gait Examination in Patients With Hemophilia in Austria

NCT ID: NCT03541811

Last Updated: 2019-08-07

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

42 participants

Study Classification

OBSERVATIONAL

Study Start Date

2018-07-02

Study Completion Date

2019-07-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Hemophilia is an inherited disease caused by deficiency in varying degrees of clotting factors VIII and IX. Depending on the percentage of clotting factor in the blood the disease is categorized as "severe" (\<1%, characterized by spontaneous bleedings), "moderate" (1-5%) and "mild" (\>5%). If untreated, recurrent bleeding into the synovial joints often results in irreversible damage due to destruction of the cartilages and progressive joint impairment.

3d-gait analysis has been demonstrated as valid method to assess abnormal gait patterns and to monitor disease progression in patients with hemophilia (PWH). Furthermore, its outcomes facilitate the design of individually tailored therapeutic programs. In contrast to radiological examinations, 3d-gait analyses take place under weight-bearing conditions, which is a relevant issue in terms of weight-induced pain.

This study aims to explore the applicability of 3-d gait analysis as biomarker (gait deviation index) for functional impairments in PWH. Besides 3-d gait scores, secondary endpoints such as biomarkers reflecting cartilage damage and a laterality-ratio of leg muscle mass (in the case of one-sided target joints) will be tested for their ability to detect functional impairments in young adults with hemophilia.

Based on sample size calculation, 24 subjects aged 16-49 years, able to walk without aids or assistance will be included in each of the two groups: control (healthy, male), PWH (severe or moderate, treated prophylactically). Subjects suffering from functional impairments caused by other conditions than hemophilia, patients with bleedings within 30 days prior to the examination, PWH treated with immune-tolerance therapy and/or not successfully treated present or past high-titer factor VIII or FIX inhibitor will be excluded.

Subjects will pass through a set of examinations (medical history, clinical examination, 3d-gait analysis, anthropometrics, body composition analysis, venipuncture, and urine sampling) and carry an accelerometer device for seven consecutive days.

Confounder adjusted group differences will be assessed by ANCOVA with contrasts and Bonferroni correction. Correlations between the applied examination approaches will be assessed.

An evidence based health promotion program including follow-up examinations, physical activity promotion, and tailored physiotherapy are being envisaged as a follow-up project (JOSEPHA phase 2).

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Hemophilia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

CROSS_SECTIONAL

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

patients with hemophilia (16-45y)

not applicable (no intervention administered)

3-d gait examination (level walking)

Intervention Type DIAGNOSTIC_TEST

Instrumented 3d-gait-analysis will be carried out in the movement lab of the FH (Fachhochschule; University of Applied Sciences) Campus Wien - University of Applied Sciences. The system used is a 10 camera T40S Vicon system with two floor-mounted AMTI OR6/7-2000 force plates. For assessing gait the Plug-in-Gait Lower Body Model with 14 mm retroreflective skin-mounted markers is implemented in the capturing software Vicon Nexus 2.2. The specific parameters will be extracted from the reporting software Vicon Polygon 4.2.

Markers will be placed by one experienced examiner. Subjects will be instructed to walk barefoot on a 10 meters walkway at self-paced walking speed until five right and five left valid first force plate strikes are captured.

Anthropometrics and body composition assessment

Intervention Type DIAGNOSTIC_TEST

Body height will be measured with the stadiometer Seca 213 to the next 0.1cm. Body size and weight will be measured without shoes and outerwear. A correction of 1 kg will be subtracted for clothing. Body weight and body composition will be assessed with the medical body composition analyzer Seca mBCA 515 based on bioelectric impedance analysis.

Biomarkers

Intervention Type DIAGNOSTIC_TEST

Blood will be collected into Vacuette serum-separating tubes and will be kept at room temperature for 30 min. Samples will be centrifuged at 1500g for 10 min and serum aliquots will be stored at 80 C until use. Urine samples will be collected into Vacuette tubes containing no additive from non-fasted individuals between 8:00 and 12:00 a.m. Urine samples will be kept at 4 °C for a maximum of 8 h, and then aliquoted and stored at 80 °C.

All biomarkers (except vitamin D and CRP) will be measured in duplicates using standard enzyme-linked immunosorbent assay (ELISA) kits. Serum samples will be assessed for the level of sCOMP, sC1,2C, and sCS846, IL-6, IL-1, sTNFR1 and sTNFR2. Vitamin D and CRP will be measured using automated immunoassay. In urine samples uCTX-II will be determined and these levels will be corrected for creatinine levels (Jaffé method, in-house validated method).

Clinical examination

Intervention Type DIAGNOSTIC_TEST

Hemophilia joint health score (HJHS) will be assessed. Height will be measured with a stadiometer (SECA 213), weight with a medical scale (Marsden M-420) and leg length according to the Plug-in-Gait protocol with a measuring tape from the Anterior Spina Iliaca Superior to the distal aspect of the Medial Malleolus. Further anthropometrical parameters taken will be knee distance and malleoli distance by using a caliper. Gait relevant passive joint ROM of the knee, hip and ankle will be assessed by means of a handheld goniometer. The flexibility of hamstring muscles will be expressed as Popliteal Angle measured with a goniometer with the subjects supine and the hip in 90° flexion.

Habitual physical activity tracking (accelerometer based)

Intervention Type DIAGNOSTIC_TEST

Participants will be instructed to wear an Actigraph wGT3X-BT tri-axial accelerometer permanently over a period of seven consecutive days with an elastic band on right hand sided hip. Data will be process with software ActiLife version 6.13. Cut-offs of at least 10 hours daily wear-time and a minimum of three valid weekdays and one valid weekend day will be applied for data cleaning. Count sampling epoch will be set at one minute. The so called Freedson Adult VM2 Cut-Offs will be applied to categorize physical activity intensities. The so called Freedson VM3 Combination will be applied for the estimation of activity energy expenditure.

peer-matched healthy control

not applicable (no intervention administered)

3-d gait examination (level walking)

Intervention Type DIAGNOSTIC_TEST

Instrumented 3d-gait-analysis will be carried out in the movement lab of the FH (Fachhochschule; University of Applied Sciences) Campus Wien - University of Applied Sciences. The system used is a 10 camera T40S Vicon system with two floor-mounted AMTI OR6/7-2000 force plates. For assessing gait the Plug-in-Gait Lower Body Model with 14 mm retroreflective skin-mounted markers is implemented in the capturing software Vicon Nexus 2.2. The specific parameters will be extracted from the reporting software Vicon Polygon 4.2.

Markers will be placed by one experienced examiner. Subjects will be instructed to walk barefoot on a 10 meters walkway at self-paced walking speed until five right and five left valid first force plate strikes are captured.

Anthropometrics and body composition assessment

Intervention Type DIAGNOSTIC_TEST

Body height will be measured with the stadiometer Seca 213 to the next 0.1cm. Body size and weight will be measured without shoes and outerwear. A correction of 1 kg will be subtracted for clothing. Body weight and body composition will be assessed with the medical body composition analyzer Seca mBCA 515 based on bioelectric impedance analysis.

Biomarkers

Intervention Type DIAGNOSTIC_TEST

Blood will be collected into Vacuette serum-separating tubes and will be kept at room temperature for 30 min. Samples will be centrifuged at 1500g for 10 min and serum aliquots will be stored at 80 C until use. Urine samples will be collected into Vacuette tubes containing no additive from non-fasted individuals between 8:00 and 12:00 a.m. Urine samples will be kept at 4 °C for a maximum of 8 h, and then aliquoted and stored at 80 °C.

All biomarkers (except vitamin D and CRP) will be measured in duplicates using standard enzyme-linked immunosorbent assay (ELISA) kits. Serum samples will be assessed for the level of sCOMP, sC1,2C, and sCS846, IL-6, IL-1, sTNFR1 and sTNFR2. Vitamin D and CRP will be measured using automated immunoassay. In urine samples uCTX-II will be determined and these levels will be corrected for creatinine levels (Jaffé method, in-house validated method).

Clinical examination

Intervention Type DIAGNOSTIC_TEST

Hemophilia joint health score (HJHS) will be assessed. Height will be measured with a stadiometer (SECA 213), weight with a medical scale (Marsden M-420) and leg length according to the Plug-in-Gait protocol with a measuring tape from the Anterior Spina Iliaca Superior to the distal aspect of the Medial Malleolus. Further anthropometrical parameters taken will be knee distance and malleoli distance by using a caliper. Gait relevant passive joint ROM of the knee, hip and ankle will be assessed by means of a handheld goniometer. The flexibility of hamstring muscles will be expressed as Popliteal Angle measured with a goniometer with the subjects supine and the hip in 90° flexion.

Habitual physical activity tracking (accelerometer based)

Intervention Type DIAGNOSTIC_TEST

Participants will be instructed to wear an Actigraph wGT3X-BT tri-axial accelerometer permanently over a period of seven consecutive days with an elastic band on right hand sided hip. Data will be process with software ActiLife version 6.13. Cut-offs of at least 10 hours daily wear-time and a minimum of three valid weekdays and one valid weekend day will be applied for data cleaning. Count sampling epoch will be set at one minute. The so called Freedson Adult VM2 Cut-Offs will be applied to categorize physical activity intensities. The so called Freedson VM3 Combination will be applied for the estimation of activity energy expenditure.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

3-d gait examination (level walking)

Instrumented 3d-gait-analysis will be carried out in the movement lab of the FH (Fachhochschule; University of Applied Sciences) Campus Wien - University of Applied Sciences. The system used is a 10 camera T40S Vicon system with two floor-mounted AMTI OR6/7-2000 force plates. For assessing gait the Plug-in-Gait Lower Body Model with 14 mm retroreflective skin-mounted markers is implemented in the capturing software Vicon Nexus 2.2. The specific parameters will be extracted from the reporting software Vicon Polygon 4.2.

Markers will be placed by one experienced examiner. Subjects will be instructed to walk barefoot on a 10 meters walkway at self-paced walking speed until five right and five left valid first force plate strikes are captured.

Intervention Type DIAGNOSTIC_TEST

Anthropometrics and body composition assessment

Body height will be measured with the stadiometer Seca 213 to the next 0.1cm. Body size and weight will be measured without shoes and outerwear. A correction of 1 kg will be subtracted for clothing. Body weight and body composition will be assessed with the medical body composition analyzer Seca mBCA 515 based on bioelectric impedance analysis.

Intervention Type DIAGNOSTIC_TEST

Biomarkers

Blood will be collected into Vacuette serum-separating tubes and will be kept at room temperature for 30 min. Samples will be centrifuged at 1500g for 10 min and serum aliquots will be stored at 80 C until use. Urine samples will be collected into Vacuette tubes containing no additive from non-fasted individuals between 8:00 and 12:00 a.m. Urine samples will be kept at 4 °C for a maximum of 8 h, and then aliquoted and stored at 80 °C.

All biomarkers (except vitamin D and CRP) will be measured in duplicates using standard enzyme-linked immunosorbent assay (ELISA) kits. Serum samples will be assessed for the level of sCOMP, sC1,2C, and sCS846, IL-6, IL-1, sTNFR1 and sTNFR2. Vitamin D and CRP will be measured using automated immunoassay. In urine samples uCTX-II will be determined and these levels will be corrected for creatinine levels (Jaffé method, in-house validated method).

Intervention Type DIAGNOSTIC_TEST

Clinical examination

Hemophilia joint health score (HJHS) will be assessed. Height will be measured with a stadiometer (SECA 213), weight with a medical scale (Marsden M-420) and leg length according to the Plug-in-Gait protocol with a measuring tape from the Anterior Spina Iliaca Superior to the distal aspect of the Medial Malleolus. Further anthropometrical parameters taken will be knee distance and malleoli distance by using a caliper. Gait relevant passive joint ROM of the knee, hip and ankle will be assessed by means of a handheld goniometer. The flexibility of hamstring muscles will be expressed as Popliteal Angle measured with a goniometer with the subjects supine and the hip in 90° flexion.

Intervention Type DIAGNOSTIC_TEST

Habitual physical activity tracking (accelerometer based)

Participants will be instructed to wear an Actigraph wGT3X-BT tri-axial accelerometer permanently over a period of seven consecutive days with an elastic band on right hand sided hip. Data will be process with software ActiLife version 6.13. Cut-offs of at least 10 hours daily wear-time and a minimum of three valid weekdays and one valid weekend day will be applied for data cleaning. Count sampling epoch will be set at one minute. The so called Freedson Adult VM2 Cut-Offs will be applied to categorize physical activity intensities. The so called Freedson VM3 Combination will be applied for the estimation of activity energy expenditure.

Intervention Type DIAGNOSTIC_TEST

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Vicon ActiGraph GT9X Link

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Provide signed and dated informed consent form (additionally from guardian for participants aged under 18 years)
* Willing to comply with all study procedures and be available for the duration of the study
* Diagnosed severe or moderate hemophilia A or B
* Age between 16 and 49 years
* Able to walk without aids or assistance
* Treated with prophylactic substitution, initiated until the age of 18 years


* Provide signed and dated informed consent form (additionally from guardian for participants aged under 18 years)
* Willing to comply with all study procedures and be available for the duration of the study
* Male
* Age between 16 and 49 years (no blood samples for participants aged under 18 years)
* Physiological and symmetric gait pattern without using aids or assistance

Exclusion Criteria

* Subjects suffering from functional impairments caused by other conditions than hemophilia
* PWH with joint bleedings within 30 days prior to the examination (applies for test group only)
* PWH treated with immune-tolerance therapy and/or not successfully treated present or past high-titer factor VIII or FIX inhibitor (applies for test group only)
Minimum Eligible Age

16 Years

Maximum Eligible Age

49 Years

Eligible Sex

MALE

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Medical University of Vienna

OTHER

Sponsor Role collaborator

Shire

INDUSTRY

Sponsor Role collaborator

FH Campus Wien, University of Applied Sciences

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Peter Putz

Researcher

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Peter Putz, Dr

Role: PRINCIPAL_INVESTIGATOR

FH Campus Wien, Department Health Sciences

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

FH Campus Wien - University of Applied Sciences

Vienna, , Austria

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Austria

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

JOSEPHA Phase 1

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Sonography and Haemophilia
NCT04550988 UNKNOWN