A Prospective Case Series Evaluating Surgimend Mp® In Patients Undergoing Complex Abdominal Hernia Repair

NCT ID: NCT03450473

Last Updated: 2023-02-15

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

24 participants

Study Classification

INTERVENTIONAL

Study Start Date

2018-01-03

Study Completion Date

2022-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Large abdominal wall hernias are surgically challenging to repair and often associated with significant postoperative complications. Risk factors associated with surgical site complications, such as infection and wound dehiscence, include obesity, diabetes, and smoking. In these high risk patients, the placement of synthetic mesh increases the risk of mesh infection, enterocutaneous fistula formation, and mesh explantation. One of the larger studies of risk factors associated with mesh explantation demonstrated concomitant intra-abdominal procedures have a greater than 6-fold increased hazard of subsequent mesh explantation. As an alternative to synthetic meshes, bioprosthetic meshes derived from the decellularization and processing of allogeneic or xenogeneic tissue sources have been introduced that can often allow the surgeon to treat the surgical site occurrences and salvage the repair without required mesh explantation. Low rates of mesh infection and explantation have been reported for bioprosthetic meshes and are recommended in these complicated patients by the Ventral Hernia Working Group, based on the best available clinical evidence. Despite widespread use of bioprosthetic mesh, there continues to be concern for complications associated with their use (i.e. high seroma and recurrence rates, etc.). This has led to the modification of these matrices by several industry leaders (Acelity, Cook, Integra, etc.) to include a fenestrated platform to allow for fluid to flow through the matrix upon implantation while supporting regeneration in complex abdominal wall reconstruction. To our knowledge, there are no clinical studies prospectively evaluating the long term clinical outcomes for abdominal wall reconstruction procedures involving fenestrated macropourous biologic matrices.This macroporous technology allows for tissue revascularization and integration of the biologic graft and thus an expected improvement in overall outcome. Bioprosthetic fenestrated materials such as Surgimend MP® were developed to assist with earlier incorporation and vascularization of the biologic graft while providing reinforcement of hernia repair. However, there is an absence of high quality prospective data regarding the use of these materials in complicated abdominal wall reconstruction, and no comparative data exists.

This study is a prospective, case series study evaluating the efficacy and performance of SurgiMend MP® during complex ventral hernia repairs. This case series involves a biologically derived hernia mesh under its cleared FDA indication for hernia repair. Efficacy will be determined by quantifying surgical complications, hernia recurrence, and cost effectiveness endpoints.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Large abdominal wall hernias are surgically challenging to repair and often associated with significant postoperative complications. Risk factors associated with surgical site complications, such as infection and wound dehiscence, include obesity, diabetes, and smoking. In these high risk patients, the placement of synthetic mesh increases the risk of mesh infection, enterocutaneous fistula formation, and mesh explantation. One of the larger studies of risk factors associated with mesh explantation demonstrated concomitant intra-abdominal procedures have a greater than 6-fold increased hazard of subsequent mesh explantation. As an alternative to synthetic meshes, bioprosthetic meshes derived from the decellularization and processing of allogeneic or xenogeneic tissue sources have been introduced that can often allow the surgeon to treat the surgical site occurrences and salvage the repair without required mesh explantation. Low rates of mesh infection and explantation have been reported for bioprosthetic meshes and are recommended in these complicated patients by the Ventral Hernia Working Group, based on the best available clinical evidence. Despite widespread use of bioprosthetic mesh, there continues to be concern for complications associated with their use (i.e. high seroma and recurrence rates, etc.). This has led to the modification of these matrices by several industry leaders (Acelity, Cook, Integra, etc.) to include a fenestrated platform to allow for fluid to flow through the matrix upon implantation while supporting regeneration in complex abdominal wall reconstruction. To our knowledge, there are no clinical studies prospectively evaluating the long term clinical outcomes for abdominal wall reconstruction procedures involving fenestrated macropourous biologic matrices.This macroporous technology allows for tissue revascularization and integration of the biologic graft and thus an expected improvement in overall outcome. Bioprosthetic fenestrated materials such as Surgimend MP® were developed to assist with earlier incorporation and vascularization of the biologic graft while providing reinforcement of hernia repair. However, there is an absence of high quality prospective data regarding the use of these materials in complicated abdominal wall reconstruction, and no comparative data exists.

This study is a prospective, case series study evaluating the efficacy and performance of SurgiMend MP® during complex ventral hernia repairs. This case series involves a biologically derived hernia mesh under its cleared FDA indication for hernia repair. Efficacy will be determined by quantifying surgical complications, hernia recurrence, and cost effectiveness endpoints.

Subjects will be identified by the investigators and/or personnel assigned by the investigators, as patients with large complex ventral hernia expected to be repaired with bioprosthetic mesh.

Subjects will have a baseline visit where they will have a physical exam and complete quality of life questionnaires and a pain scale. Photographs will be taken at this visit as well. Demographic and medical and surgical history will be collected. The investigators will then assess the subject intra-operatively to confirm the need and appropriate placement of SurgiMend mesh. The subjects that have mesh placed will be followed at hospital discharge, 3 months, 6 months, and 12 months to assess for changes in health, adverse events, questionnaire completion, and evaluation of surgical site for complications and recurrence. The visits may take place by phone if the subject cannot return to clinic.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Hernia, Ventral

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

SurgiMend® MP

Patients will not be randomized as this is a case series study involving the evaluation of only 1 type of mesh (SurgiMend MP®).

Group Type OTHER

SurgiMend® MP

Intervention Type DEVICE

SurgiMend MP® is an acellular dermal tissue matrix derived from bovine dermis. The device is supplied sterile in a variety of sizes to be trimmed by the surgeon to meet the individual patient's needs. SurgiMend MP® will be used for abdominal wall reinforcement in patients with complex ventral hernia repair.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

SurgiMend® MP

SurgiMend MP® is an acellular dermal tissue matrix derived from bovine dermis. The device is supplied sterile in a variety of sizes to be trimmed by the surgeon to meet the individual patient's needs. SurgiMend MP® will be used for abdominal wall reinforcement in patients with complex ventral hernia repair.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Men or women ≥ 18 years of age and able to give their own consent.
2. The subject is able and willing to comply with study procedures and a signed and dated informed consent is obtained.
3. The subject has a complex ventral hernia
4. The surgeon intends to use bioprosthetic mesh in the repair of the hernia
5. The hernia meets the definition of complex.

For this study a hernia defect will be considered complex if:

5.1. a hernia defect is large enough to require component separation to achieve midline fascial closure under physiologic tension 5.2. or the surgical wound is class II -potentially contaminated or class III - contaminated without signs of infection as defined by the CDC wound classification (see Table 1) 5.3. or a patient classified as at risk for surgical site complications by having 2 or more of the following comorbidities:
* Current smoker or recent history of smoking
* Obesity (BMI ≥ 30)
* Type I or Type II diabetes
* Chronic Obstructive Pulmonary Disease (COPD)
* Poor nutritional status as judged by the Investigator
* Current immunosuppressive therapy
* Current and/or recent (within 30 days of planned surgery) Corticosteriod use
* Prior Mesh infection
6. Life expectancy of the patient is considered by the physician to be greater than at least 1 year
7. The subject has no known hypersensitivity to bovine collagen
8. The subject has no obvious condition interfering with their ability to comply with the treatment regimen
9. The subject is willing and capable of returning for all follow-up evaluations, in the opinion of the treating physician

Exclusion Criteria

Pre-Operative Exclusion:

1. \< 18 years of age
2. Have abdominal loss of domain such that the operation would be impractical or would adversely affect respiratory or cardiovascular function to an unacceptable degree in the opinion of the Investigator
3. Participation in an investigational drug or device study within the past 6 weeks prior to enrollment into this trial
4. Have a known collagen metabolism disorder or any medical condition that could interfere with normal tissue healing process as determined by the Investigator



1. Primary closure of the skin and subcutaneous tissue is not achieved at the index operation
2. Bioprosthetic mesh was not used in the repair for any reason
3. Primary Fascial closure unable to be obtained i.e. bridged closure
4. Unable to place the mesh in the retrorectus space (no intraperitoneal placement)
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Washington University School of Medicine

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Grant Bochicchio, MD, MPH

Role: PRINCIPAL_INVESTIGATOR

Washington University School of Medicine

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Barnes Jewish Hospital

St Louis, Missouri, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

WU001 Surgimend Mp®

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

SurgiMend Mesh at the Hiatus
NCT04282720 COMPLETED NA
Reducing Mesh Infections in Open Hernia Repairs
NCT01860469 UNKNOWN PHASE2/PHASE3