Global Post-market Registry for the Treovance Stent-graft.
NCT ID: NCT03449875
Last Updated: 2020-06-26
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
202 participants
OBSERVATIONAL
2014-02-05
2017-04-11
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Treovance Stent-Graft With Navitel Delivery System for Patients With Infrarenal Abdominal Aortic Aneurysms
NCT01328197
Clinical Study of the Treovance Stent-Graft for Patients With Abdominal Aortic Aneurysms
NCT02009644
Post-Approval Study of the TREO Abdominal Stent-Graft System
NCT04697784
A Phase I Evaluation of the Safety of the TriVascular Stent-Graft System in the Treatment of Abdominal Aortic Aneurysms
NCT00646048
TriVascular Post-Market Registry
NCT01372709
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The following endovascular measures/parameters were assessed for preliminary performance at the follow-up intervals: delivery/deployment, stent-graft migration, stent-graft patency, stent-graft integrity, endoleak, aneurysm sac size changes, limb ischemia, and vascular access complications.
This registry was a prospective, multi-center, post-market non-randomized study. The goal was to gather safety and performance data on the device. Subjects diagnosed with infrarenal aortic aneurysms enrolled into the registry were treated with the TREOVANCE® Stent-Graft with Navitel® Delivery System. Pre-procedure baseline data was gathered as well as post-procedure assessments prior to hospital discharge and 1, 6, and 12 months post-implantation.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
TREOVANCE® Stent-Graft with Navitel® Delivery System
Endovascular repair of abdominal aortic aneurysms.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Subject must be diagnosed with an infrarenal abdominal aortic aneurysm (AAA), with or without iliac artery involvement, by CT with contrast performed within 3 months of planned implant procedure.
* Subject must have an infrarenal AAA that i. is \> 4.5 cm in diameter for females and \> 5 cm for males. ii. has increased in diameter by 0.5 cm in the last 6 months
* Subject must have i. infrarenal landing neck length of 10 mm or greater and an angle of less than 60 degrees relative to the long axis of the aneurysm (centerline at lowest renal to centerline at bifurcation) and a suprarenal neck angle of less than 45 degrees relative to the infrarenal neck axis and an inside diameter of 17 mm - 32 mm, or ii. infrarenal landing neck length of 15 mm or greater and an angle of between 60 and 75 degrees relative to the long axis of the aneurysm and a suprarenal neck angle of less than 45 degrees relative to the infrarenal neck axis and an inside diameter of 16 mm-30 mm
* Subject's infrarenal landing neck must i. have no significant calcification or thrombus formation, and ii. meet the vessel size requirements specified in the instructions for use (IFU) for the corresponding devices
* Subject must have lowest renal artery at least 9 cm from the aortic bifurcation
* Subject must have a distal iliac landing neck with i. an inside diameter of 7 mm - 13 mm and a length of at least 10 mm, or ii. an inside diameter of \>13 mm - 20 mm and a length of at least 15 mm
* Subject's distal iliac landing neck must i. have no significant calcification or thrombus formation, and ii. meet the vessel size requirements specified for the corresponding devices in the IFU
* Subject must have a total treatment length of at least 13 cm
* Subject must be willing and able to comply with 1-month, 6-month, and 12-month follow-up visits.
* Subject must have adequate vascular access (e.g., patent iliac or femoral arteries) for introduction of the Navitel® Delivery System which is 18F (6 mm) or 19F (6.3 mm) outer diameter based on size of device used. Alternatively, subject's anatomy is suitable for creation of an iliac conduit.
* Subject or Legally Authorized Representative (LAR) must agree to sign hospital issued Informed Consent Form
Exclusion Criteria
* Subject has a dissection or a ruptured aneurysm (as determined by treating physician).
* Subject has a patent inferior mesenteric artery that cannot be sacrificed and an occluded or stenotic celiac and/or superior mesenteric artery
* Implant procedure as planned does not allow for at least one patent hypogastric artery left intact, unless both are occluded on pre-op imaging
* Subject has a lesion that cannot be crossed by a guide wire
* Proximal neck cannot increase by more than 20% over 15 mm; i.e., no conical necks
* Subject has severe untreated coronary artery disease and/or unstable angina, significant areas of myocardium at risk (based on coronary angiogram or radionuclide scans), left ventricular ejection fraction \< 20%, or recent diagnosis of CHF
* Subject has had a stroke or MI within 6 months of the planned treatment date
* Subject has chronic obstructive pulmonary disease requiring routine need for oxygen therapy outside the hospital setting (e.g., daily or nightly home use)
* Subject has an active systemic infection or is suspected of having an active systemic infection (e.g., AIDS/HIV, sepsis)
* Subject is morbidly obese (more than 100% over the ideal body weight or as defined by institutional standards) or has other clinical conditions that severely compromise or impair x-ray visualization of the aorta
* Subject has significant or circumferential mural thrombus in the proximal aortic neck
* Subject has a blood coagulation disorder or bleeding diathesis the treatment for which cannot be suspended pre- and post-repair
* Subject is in acute or chronic renal failure (creatinine \> 2.5 mg/dL)
* Subject has less than two-year life expectancy as evidenced by factors prohibiting major medical intervention (e.g., presence of malignancy, severe cardiopulmonary disease, etc.)
* Subject is participating in another research study, has received investigational study drug within 30 days of planned procedure, or has received an investigational device within one year of planned procedure.
* Subject is confronted with other medical, social or psychological issues that the investigator believes may interfere with study treatment or follow-up. These reasons must be documented. An example may include adherence to a theological or personal doctrine with aversion or opposition to blood transfusion.
* Subject has had a prior AAA repair (endovascular or surgical)
* Subject has an untreatable allergy or sensitivity to contrast media, nitinol/nickel, or polyester
* Subject has undergone other major surgical or medical intervention within 45 days of the planned procedure or is planning to undergo other major surgical or medical intervention within 45 days post implantation (e.g., CABG, organ transplantation, renal stenting, etc.)
18 Years
85 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Bolton Medical
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Carlo Setacci, MD, PhD
Role: STUDY_CHAIR
Department of Medicine, Surgery and Neuroscience, University of Siena Viale Bracci 1, 53100 Siena, Italy
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Hospital Barros Luco Trudeau
Santiago, , Chile
Hospital de la Dirección de Previsión de Carabineros de Chile
Santiago, , Chile
Rigshospitalet, National Hospital and University of Copenhagen
Copenhagen, , Denmark
Deutsches Herzzentrum Berlin
Berlin, , Germany
Bonifatius Hospital
Lingen, , Germany
Theresienkrankenhaus und St. Hedwig-Klinik
Mannheim, , Germany
Universitätsklinikum Tübingen
Tübingen, , Germany
Evaggelismos General Hospital
Athens, , Greece
Georgios Gennimatas Thessaloniki General Hospital
Thessaloniki, , Greece
Queen Mary Hospital, University of Hong Kong
Hong Kong, , Hong Kong
Semmelweis Medical University Budapest
Budapest, , Hungary
Cork University Hospital
Cork, , Ireland
Casa Di Cura Villa Dei Fiori
Acerra, , Italy
Azienda Ospedaliera San Camillo Forlanini
Roma, , Italy
Azienda Ospedaliera Universitaria Senese
Siena, , Italy
ZiekenhuisGroep Twente
Almelo, , Netherlands
Universitair Medisch Centrum Utrecht
Utrecht, , Netherlands
Haukeland University Hospital
Bergen, , Norway
Samodzielny Publiczny Szpital Kliniczny Nr 1
Lublin, , Poland
Hospital HM Modelo
A Coruña, , Spain
Hospital Germans Trias i Pujol
Badalona, , Spain
Hospital Clínic de Barcelona
Barcelona, , Spain
Hospital Universitario Ramón y Cajal
Madrid, , Spain
Complexo Hospitalario Universitario de Ourense
Ourense, , Spain
Linköping University Hospital
Linköping, , Sweden
Karolinska University Hospital
Solna, , Sweden
Lampang Hospital
Lampang, , Thailand
Addenbrooke's Hospital, Cambridge University Hospitals
Cambridge, , United Kingdom
Manchester Royal Infirmary, Central Manchester University Hospitals
Manchester, , United Kingdom
John Radcliffe Hospital, Oxford University Hospitals
Oxford, , United Kingdom
Instituto Urológico San Román
Caracas, , Venezuela
Cho Ray Hospital
Ho Chi Minh City, , Vietnam
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Murray D, Szeberin Z, Benevento D, Abdallah F, Palasciano G, Lescan M, Uberoi R, Setacci C. A comparison of clinical outcomes of abdominal aortic aneurysm patients with favorable and hostile neck angulation treated by endovascular repair with the Treovance stent graft. J Vasc Surg. 2020 Jun;71(6):1881-1889. doi: 10.1016/j.jvs.2019.07.096. Epub 2019 Nov 2.
Uberoi R, Setacci C, Lescan M, Lorido A, Murray D, Szeberin Z, Zubilewicz T, Riambau V, Chartrungsan A, Tessarek J; RATIONALE Investigators. Global Post-Market Clinical Follow-up of the Treovance Stent-Graft for Endovascular Aneurysm Repair: One-Year Results From the RATIONALE Registry. J Endovasc Ther. 2018 Dec;25(6):726-734. doi: 10.1177/1526602818803939. Epub 2018 Oct 3.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IP-0024-17
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.