Electrical Safety of Implantable Cardioverter Defibrillators

NCT ID: NCT03271619

Last Updated: 2018-01-11

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

25 participants

Study Classification

OBSERVATIONAL

Study Start Date

2014-02-28

Study Completion Date

2018-01-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Patients at risk of developing life-threatening heart rhythms may require the implantation of a small device called a cardioverter-defibrillator (ICD), which constantly monitors the heart rhythm and delivers an electrical shock to the heart when indicated, in order to return the heart back to a normal rhythm. Many thousands of these devices have been implanted and are electrically active in patients who collapse and need resuscitation.

When a patient with an ICD collapses, the device may discharge without warning while a rescuer is performing external chest compressions (cardiac massage). Conventional ICDs placed below the left collar bone typically deliver 35-50 J energy when they discharge, but newer ICDs placed under the skin (S-ICD) alongside the breastbone deliver a larger energy when discharging; typically 50-80J energy.

Rescuers performing external chest compressions on a patient during conventional ICD discharge have reported the sensation of a painful electrical shock and permanent nerve damage. In these situations, rescuers appear to have been exposed to electrical current from the ICD considerably in excess of that which is considered a safe threshold.

Studies of surface current resulting from discharge of conventional ICDs have been reported in excess of 100 mA which is far in excess of the safe 1 mA limit, and puts the rescuer at considerable risk of tissue damage and possible dangerous heart rhythms. The newer S-ICDs deliver approximately 50% more energy and have the potential to result in exposure of a rescuer to even higher currents.

With increasing numbers of the S-ICDs being implanted, and the inevitability that rescuers will soon find themselves exposed to leakage current from these devices, there is a need to examine the leakage currents arising from these devices and assess any subsequent risk to a rescuer performing external chest compressions.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Rationale for Study:

When patients undergo elective implantation of an ICD, the device is tested by inducing ventricular fibrillation (VF) in the patient and allowing the ICD to sense, charge and discharge in an attempt to shock the patient back into a normal rhythm. This provides a controlled, elective situation in which to measure the cutaneous current on the patient's skin which is the current to which a rescuer could potentially be exposed.

By understanding the leakage currents from these devices, the investigators will be able to better understand the safety of rescuers in contact with patients fitted with an ICD and make specific recommendations to enable to safe undertaking of uninterrupted external chest compressions while the ICD may be discharging.

STUDY OBJECTIVES

Primary Objective:

To measure cutaneous leakage current on the chest wall during conventional and S-ICD discharge.

Secondary Objectives:

To make recommendations based on this data regarding the safety of rescuers in contact with a patient during ICD discharge.

ENDPOINTS

Primary Endpoint:

Maximum cutaneous current measured at multiple sites on the chest wall during ICD discharge.

STUDY DESIGN This is a prospective cohort study, aiming to study sequential patients undergoing elective ICD implantation and testing over a 12 month period at University Hospital Southampton.

The patient will undergo elective ICD implantation according to normal protocol. There will be no change in their treatment. After induction of general anaesthesia, an array of small self-adhesive electrodes (similar to ECG 'dots') will be placed on the patient's chest wall, and connected to a multichannel recording device.

After implantation of the ICD, the device will be tested as per normal protocol. VF is induced in the patient. The ICD senses this arrhythmia, charges and immediately delivers a shock to the myocardium. As this shock is delivered, the investigators will record the current reaching the surface electrode array using the multichannel recorder. Most patients only require one shock as defibrillation rates with ICDs are \>90%. If a second shock is required, the ICD will charge automatically and discharge once again. If this occurs, the investigators will also measure the cutaneous current at this second, higher energy level. The study is then concluded. Any subsequent shocks are delivered through external paddles and the investigators would not require any data from this stage of the procedure.

STUDY POPULATION Number of Participants The investigators aim to assess 20 patients undergoing conventional ICD implantation and a further 20 patients undergoing S-ICD implantation.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Defibrillators, Implantable Cardiac Arrest

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Transvenous ICD

Patients with a transvenous ICD undergoing defibrillation testing.

Surface current measurement

Intervention Type OTHER

Measurement of surface current between electrodes placed on the chest wall during defibrillation

Subcutaneous ICD

Patients with a subcutaneous ICD undergoing defibrillation testing.

Surface current measurement

Intervention Type OTHER

Measurement of surface current between electrodes placed on the chest wall during defibrillation

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Surface current measurement

Measurement of surface current between electrodes placed on the chest wall during defibrillation

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients with implanted defibrillators (ICDs) undergoing defibrillation testing
* Patients undergoing ICD implantation that requires a defibrillation test at the end of the implantation.

Exclusion Criteria

* Enrolment in other ICD-related studies
* Patients \<18 yrs age
Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University Hospital Southampton NHS Foundation Trust

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Charles Deakin, MD

Role: PRINCIPAL_INVESTIGATOR

University Hospital Southampton NHS Foundation Trust

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University Hospital Southampton

Southampton, Hampshire, United Kingdom

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United Kingdom

References

Explore related publications, articles, or registry entries linked to this study.

Willcox ME, Prutkin JM, Bardy GH. Recent developments in the subcutaneous ICD. Trends Cardiovasc Med. 2016 Aug;26(6):526-35. doi: 10.1016/j.tcm.2016.03.004. Epub 2016 Mar 15.

Reference Type BACKGROUND
PMID: 27079889 (View on PubMed)

Chue CD, Kwok CS, Wong CW, Patwala A, Barker D, Zaidi A, Mamas MA, Cunnington C, Ahmed FZ. Efficacy and safety of the subcutaneous implantable cardioverter defibrillator: a systematic review. Heart. 2017 Sep;103(17):1315-1322. doi: 10.1136/heartjnl-2016-310852. Epub 2017 Jul 7.

Reference Type BACKGROUND
PMID: 28687562 (View on PubMed)

Perkins GD, Handley AJ, Koster RW, Castren M, Smyth MA, Olasveengen T, Monsieurs KG, Raffay V, Grasner JT, Wenzel V, Ristagno G, Soar J; Adult basic life support and automated external defibrillation section Collaborators. European Resuscitation Council Guidelines for Resuscitation 2015: Section 2. Adult basic life support and automated external defibrillation. Resuscitation. 2015 Oct;95:81-99. doi: 10.1016/j.resuscitation.2015.07.015. Epub 2015 Oct 15. No abstract available.

Reference Type BACKGROUND
PMID: 26477420 (View on PubMed)

Clements PA. Hazards of performing chest compressions in collapsed patients with internal cardioverter defibrillators. Emerg Med J. 2003 Jul;20(4):379-80. doi: 10.1136/emj.20.4.379. No abstract available.

Reference Type BACKGROUND
PMID: 12835365 (View on PubMed)

Stockwell B, Bellis G, Morton G, Chung K, Merton WL, Andrews N, Smith GB. Electrical injury during "hands on" defibrillation-A potential risk of internal cardioverter defibrillators? Resuscitation. 2009 Jul;80(7):832-4. doi: 10.1016/j.resuscitation.2009.04.010. Epub 2009 May 14.

Reference Type BACKGROUND
PMID: 19446388 (View on PubMed)

Niwano S, Kojima J, Inuo K, Saito J, Kashiwa T, Suyama M, Toyoshima T, Aizawa Y, Izumi T. Measurement of body surface energy leakage of defibrillation shock by an implantable cardioverter defibrillator. Pacing Clin Electrophysiol. 2002 Aug;25(8):1212-8. doi: 10.1046/j.1460-9592.2002.01212.x.

Reference Type BACKGROUND
PMID: 12358172 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

13/SC/0427

Identifier Type: -

Identifier Source: org_study_id