Contrast-enhanced 3D T1-weighted Gradient-echo Versus Spin-echo 3 Tesla MR Sequences in the Detection of Active Multiple Sclerosis Lesions
NCT ID: NCT03268239
Last Updated: 2026-01-06
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
180 participants
INTERVENTIONAL
2017-08-02
2021-04-26
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Objectives To compare the sensitivity of enhancing multiple sclerosis (MS) lesions in gadolinium-enhanced 3D T1-weighted gradient-echo (GRE) and turbo-spin-echo (TSE) sequences.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Performance Evaluation of a 3D PSIR Sequence in MRI at 1.5T
NCT04707144
3D Phase Sensitive Inversion Recuperation MRI to Detect and Characterize Multiple Sclerosis Spinal Cord Lesions
NCT02896647
Comparison of the Performance of an Optimized 3D EPI SWI Sequence and a Non-EPI QSM SWI Sequence in Detecting the Central Vein Sign in Patients With Multiple Sclerosis
NCT04705870
Magnetic Resonance Imaging to Detect Brain Damage in Patients With Multiple Sclerosis
NCT00321568
Disability, MRI Lesions and Thickness of Retinal Fibers: Evaluation 15 Years After a First Episode of Demyelination
NCT03268096
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
MRI sequences
There will be only one arm of patients with central nervous system inflammatory disease.
Each patient will be its own control. The usual and additional MRI sequences will be performed in all patients and the number of lesions obtained in usual sequences and additional sequences will be compared in the same patient.
Additional MRI sequences
Due to the participation in the study, the following sequences are added to the imaging protocol:
* 3D T1 GRE after injection (Gradient-Recalled Echo)
* 3D T1 TSE before injection (Turbo Spin Echo)
* 3D fGATIR PSIR after injection (fast Gray Matter Acquisition T1 Inversion Recovery Phase-Sensitive Inversion Recovery)
Sequences will be performed in a random order to avoid the bias induced by different time intervals between injection and acquisition.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Additional MRI sequences
Due to the participation in the study, the following sequences are added to the imaging protocol:
* 3D T1 GRE after injection (Gradient-Recalled Echo)
* 3D T1 TSE before injection (Turbo Spin Echo)
* 3D fGATIR PSIR after injection (fast Gray Matter Acquisition T1 Inversion Recovery Phase-Sensitive Inversion Recovery)
Sequences will be performed in a random order to avoid the bias induced by different time intervals between injection and acquisition.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Able to provide written informed consent.
* Known central nervous system inflammatory disease
* Magnetic Resonance exam needed for evaluation after a clinical event in the last 3 weeks
Exclusion Criteria
* Contraindications either to 3 Tesla Magnetic Resonance Imaging (e.g. certain metallic and electronic implants, claustrophobia) or IV gadolinium contrast (allergy, pregnancy, breast-feeding, renal insufficiency).
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Fondation Ophtalmologique Adolphe de Rothschild
NETWORK
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Fondation Ophtalmologique A. de Rothschild
Paris, France, France
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
de Panafieu A, Lecler A, Goujon A, Krystal S, Gueguen A, Sadik JC, Savatovsky J, Duron L. Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI. Invest Radiol. 2023 May 1;58(5):314-319. doi: 10.1097/RLI.0000000000000937. Epub 2022 Dec 8.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ALR_2017_11
Identifier Type: -
Identifier Source: org_study_id
More Related Trials