Contrast-enhanced 3D T1-weighted Gradient-echo Versus Spin-echo 3 Tesla MR Sequences in the Detection of Active Multiple Sclerosis Lesions

NCT ID: NCT03268239

Last Updated: 2026-01-06

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

180 participants

Study Classification

INTERVENTIONAL

Study Start Date

2017-08-02

Study Completion Date

2021-04-26

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Gadolinium-enhanced magnetic resonance imaging (MRI) is currently the imaging gold standard to detect active inflammatory lesions in multiple sclerosis (MS) patients. The sensitivity of enhanced MRI to detect active lesions may vary according to the acquisition strategy used (e.g., delay between injection and image acquisition, contrast dose, field strength, and frequency of MRI sampling). Selection of the most appropriate T1-weighted sequence after contrast injection may also influence sensitivity. Several clinical studies performed at 1.5 Tesla have shown that conventional 2D spin-echo (SE) sequences perform better than gradient recalled-echo (GRE) sequences for depicting active MS lesions after gadolinium injection. As relates to MS, 3.0 Tesla systems offer some advantages over lower field strengths, such as higher detection rates for T2 and gadolinium-enhancing brain lesions, an important capability for diagnosing and monitoring MS patients. Recent studies have shown that at 3 Tesla, 3D GRE or 3D fast SE sequences provide higher detection rates for gadolinium-enhancing MS lesions, especially smaller ones, than standard 2D SE, and better suppress artefacts related to vascular pulsation. However, the comparison of the performance of 3D GRE versus 3D SE sequences has not been investigated yet.

Objectives To compare the sensitivity of enhancing multiple sclerosis (MS) lesions in gadolinium-enhanced 3D T1-weighted gradient-echo (GRE) and turbo-spin-echo (TSE) sequences.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Magnetic Resonance Imaging Central Nervous System Brain Multiple Sclerosis Demyelinating Diseases

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

MRI sequences

There will be only one arm of patients with central nervous system inflammatory disease.

Each patient will be its own control. The usual and additional MRI sequences will be performed in all patients and the number of lesions obtained in usual sequences and additional sequences will be compared in the same patient.

Group Type OTHER

Additional MRI sequences

Intervention Type DEVICE

Due to the participation in the study, the following sequences are added to the imaging protocol:

* 3D T1 GRE after injection (Gradient-Recalled Echo)
* 3D T1 TSE before injection (Turbo Spin Echo)
* 3D fGATIR PSIR after injection (fast Gray Matter Acquisition T1 Inversion Recovery Phase-Sensitive Inversion Recovery)

Sequences will be performed in a random order to avoid the bias induced by different time intervals between injection and acquisition.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Additional MRI sequences

Due to the participation in the study, the following sequences are added to the imaging protocol:

* 3D T1 GRE after injection (Gradient-Recalled Echo)
* 3D T1 TSE before injection (Turbo Spin Echo)
* 3D fGATIR PSIR after injection (fast Gray Matter Acquisition T1 Inversion Recovery Phase-Sensitive Inversion Recovery)

Sequences will be performed in a random order to avoid the bias induced by different time intervals between injection and acquisition.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Equal or more than 18 years of age
* Able to provide written informed consent.
* Known central nervous system inflammatory disease
* Magnetic Resonance exam needed for evaluation after a clinical event in the last 3 weeks

Exclusion Criteria

* Current treatment with dimethylfumarate (Tecfidera®), natalizumab (Tysabri®) or fingolimod (Gilenya®)
* Contraindications either to 3 Tesla Magnetic Resonance Imaging (e.g. certain metallic and electronic implants, claustrophobia) or IV gadolinium contrast (allergy, pregnancy, breast-feeding, renal insufficiency).
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Fondation Ophtalmologique Adolphe de Rothschild

NETWORK

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Fondation Ophtalmologique A. de Rothschild

Paris, France, France

Site Status

Countries

Review the countries where the study has at least one active or historical site.

France

References

Explore related publications, articles, or registry entries linked to this study.

de Panafieu A, Lecler A, Goujon A, Krystal S, Gueguen A, Sadik JC, Savatovsky J, Duron L. Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI. Invest Radiol. 2023 May 1;58(5):314-319. doi: 10.1097/RLI.0000000000000937. Epub 2022 Dec 8.

Reference Type RESULT
PMID: 36729811 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

ALR_2017_11

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

A Study of Imaging in Demyelinating Diseases
NCT05805839 ENROLLING_BY_INVITATION PHASE2