Visceral Manifold Study for the Repair of Thoracoabdominal Aortic Aneurysms
NCT ID: NCT03246126
Last Updated: 2024-04-10
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
17 participants
INTERVENTIONAL
2017-11-01
2023-06-07
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Clinical Study of Thoracic Aortic Aneurysm Exclusion
NCT00549315
Valor II: The Valiant Thoracic Stent Graft System Clinical Study
NCT00413231
VALOR: The Talent Thoracic Stent Graft System Clinical Study
NCT00604799
Evaluation of the Valiant Mona LSA Thoracic Stent Graft System in Descending TAA and Chronic Dissections
NCT02365467
Endovascular Repair of Descending ThoracoAbdominal Aortic Pathologies Using Physician Modified Endovascular Prosthesis
NCT02524834
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Primary Arm: Treatment with Valiant Thoracoabdominal Stent Graft System
The implantation of the Valiant Thoracoabdominal Stent Graft System is conducted under fluoroscopic/angiographic guidance.
Valiant™Thoracoabdominal Stent Graft System
The Visceral Manifold System is comprised of the Thoracic Bifurcation and Visceral Manifold to treat a thoracoabdominal aortic aneurysm or TAAA. The experimental procedure to implant the stent graft will be done in an operating room and will last anywhere from four to eight hours, but may take longer.
Expanded Use Arm: Treatment with Valiant Thoracoabdominal Stent Graft System
The implantation of the Valiant Thoracoabdominal Stent Graft System is conducted under fluoroscopic/angiographic guidance.
Valiant™Thoracoabdominal Stent Graft System
The Visceral Manifold System is comprised of the Thoracic Bifurcation and Visceral Manifold to treat a thoracoabdominal aortic aneurysm or TAAA. The experimental procedure to implant the stent graft will be done in an operating room and will last anywhere from four to eight hours, but may take longer.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Valiant™Thoracoabdominal Stent Graft System
The Visceral Manifold System is comprised of the Thoracic Bifurcation and Visceral Manifold to treat a thoracoabdominal aortic aneurysm or TAAA. The experimental procedure to implant the stent graft will be done in an operating room and will last anywhere from four to eight hours, but may take longer.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* An aneurysm with a maximum diameter of \> 5.5 cm or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements
* Aneurysm with a history of growth \> 0.5 cm in 6 months
* Saccular aneurysm deemed at significant risk for rupture
* Symptomatic aneurysm greater than or equal to 4.5 cm
* Axillary or brachial and iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit
* Proximal landing zone for the thoracic bifurcation stent graft that has: (a) ≥ 2.5 cm of nonaneurysmal aortic segment including previously placed graft material (neck) distal to the left subclavian artery (LSA); (b) Diameter in the range of 26-42 mm; (c) Adequate distance from the celiac artery, in order to accommodate cannulation from the antegrade access point when considering the total deployed length of the thoracic bifurcation and visceral manifold
* Iliac artery or aortic distal fixation site, including both native tissue and previously placed graft, greater than or equal to 15 mm in length and diameter in the range of 8 - 25 mm
* Life expectancy: \> 1 year
* Branch vessel diameter \<5mm
* Urgent or emergent presentation
* Patient has a contained rupture
* Patient has a ruptured aneurysm
* Patient has a type B dissection (subacute or chronic) in the portion of the aorta intended to be treated
* Poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)
* Baseline creatinine greater than 2.0 mg/dL
* Anatomy that does not allow maintenance of at least one hypogastric artery
* Anatomy that does not allow primary or assisted patency of the left subclavian artery
* Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material
* Obstructive stenting of any or all of the visceral vessels
* Treatment of the patient population listed above will be considered for this expanded arm of the study if they are not a candidate for open surgical repair, cannot be treated with approved devices, and do not meet inclusion into the primary study arm as per opinion of the Principal Investigator, with the concurrence of the IRB.
Exclusion Criteria
* Can be treated in accordance with the instructions for use with a legally marketed endovascular prosthesis
* Is eligible for enrollment in a manufacturer- sponsored IDE at the investigational site
* Unwilling to comply with the follow-up schedule
* Inability or refusal to give informed consent by patient or legal representative
* Urgent or emergent presentation
* Patient is pregnant or breastfeeding
* Patient has a contained rupture
* Patient has a ruptured aneurysm
* Patient has a dissection in the portion of the aorta intended to be treated
* Obstructive stenting of any or all of the visceral vessels
* Poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)
* Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material
* Known sensitivities or allergies to the materials of construction of the devices, including nitinol (Nickel: Titanium), polyester, platinum-iridium, polytetrafluoroethylene (PTFE), platinum, gold, polyethylene, or stainless steel.
* Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed
* Uncorrectable coagulopathy
* Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment
* Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned \< 30 days of the endovascular repair
* Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina)
* Systemic or local infection that may increase the risk of endovascular graft infection
* Baseline creatinine greater than 2.0 mg/dL
* History of connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome)
* ranch vessel diameter less than 5 mm
* Thrombus or excessive calcification within the neck of the aneurysm
* Anatomy that would not allow maintenance of at least one patent hypogastric artery
* Anatomy that would not allow primary or assisted patency of the left subclavian artery
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
NYU Langone Health
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Thomas Maldonado
Role: PRINCIPAL_INVESTIGATOR
NYU Langone Health
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
New York University School of Medicine
New York, New York, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
16-01441
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.