Effects of Infrasound Exposure on Measures of Endolymphatic Hydrops
NCT ID: NCT03132961
Last Updated: 2018-10-18
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
TERMINATED
12 participants
OBSERVATIONAL
2018-05-05
2018-08-23
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The Effects of Ultrasonic Noise Exposure on Human Hearing
NCT03515928
Early Detection of Noise-Induced Hearing Loss
NCT01022710
Effectiveness of Hearing-aid Based Wind-noise Algorithm
NCT00738244
Quantification of Visually Evoked Cortical Potentials in Individuals With Hearing Loss
NCT05107466
Reversing Synchronized Brain Circuits With Targeted Auditory-Somatosensory Stimulation to Treat Phantom Percepts
NCT03621735
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
As it falls below audible thresholds, conventional wisdom would dictate that infrasound does not affect humans. However, some individuals living in proximity to wind turbines experience increased levels of annoyance and sleep disturbance in a dose-response fashion. Other reported symptoms from infrasound exposure include aural fullness, tinnitus, dizziness, and vertigo. Some researchers hypothesize that these otologic symptoms are related to the infrasonic component of wind turbine noise affecting inner ear function. However, since the mechanism or causal role have yet to be established, others attribute such symptoms to a psychosomatic or "nocebo" effect (i.e. worsening symptoms produced by negative expectations). As wind farms and other infrasound-generating sources become widespread, there is now a critical need to determine the effects of infrasound on inner ear function.
Studies conducted in humans have confirmed that infrasound has measurable effects within the cochlea. Hensel et al presented infrasound tones of 6 and 12 Hz at 130 dB sound pressure level (SPL) while simultaneously measuring distortion product otoacoustic emissions (DPOAEs). They observed considerable increases in DPOAE amplitudes in the presence of infrasound compared to when these tones were absent. The authors attributed this effect to the displacement of the cochlear partition during infrasound exposure. Further, Dommes et al demonstrated activity in the primary auditory cortex on functional magnetic resonance imaging during infrasound exposure, providing evidence that perception of infrasound occurs through known auditory pathways.
Reversible hydropic changes of the endolymphatic space have been observed during short-term exposure to infrasound and low frequency sound in several guinea pig models. Flock and Flock utilized an explanted guinea pig temporal bone model to visualize expansion of the endolymphatic space on confocal microscopy while applying tone bursts of 140 Hz between 88-112 dB. Shortly after this work, Salt detected changes indicative of endolymphatic hydrops in vivo using volume and flow markers iontophoresed into the endolymphatic space of guinea pigs during 3 minutes of exposure to 200 Hz tone bursts at 115 dB SPL. The observed changes in flow and volume in the endolymphatic space were reversible. The recovery half time in this study was 3.2 minutes. Subsequent work by Salt et al demonstrated that infrasound at 5 Hz generated larger endolymphatic potentials in the third cochlear turn than did frequencies in the audible range from 50-500 Hz. This was despite a presentation level expected to be below the hearing threshold of the guinea pigs. These studies demonstrate that infrasound and low-frequency tones have measurable effects on inner ear physiology, even at sub-threshold hearing levels.
While there is evidence that the human cochlea is stimulated by infrasound, it is not known if infrasound induces endolymphatic hydrops in humans. The proposed work will test the central hypothesis that short-term infrasound exposure induces reversible endolymphatic hydrops in the human inner ear. This hypothesis is based on the observations in the presented animal studies and the observed combination of auditory and vestibular symptoms reported to be associated with infrasound exposure.
In order to test the hypothesis in living humans, the proposed study will utilize electrophysiologic tests that are currently employed as clinical tests for endolymphatic hydrops. By using a combination of tests, evidence of hydrops will be sought in both the cochlea and the vestibular system.
1. Electrocochleography (ECoG). ECoG is an electrophysiologic test of cochlear function. Conditions such as Ménière's disease, which are characterized by endolymphatic hydrops, demonstrate an elevated summating potential to action potential (SP/AP) ratio on electrocochleography (ECoG). An increase in the SP relative to the AP is thought to be due to a deflection of the basilar membrane position toward the scala tympani. Accordingly, abnormal ECoG has been correlated with the finding of cochlear hydrops (in the basal turn) on gadolinium-enhanced MRI.
2. Vestibular evoked myogenic potentials (VEMPs). VEMPs arise from sound-induced activation of otolith organs and their associated vestibular neurons. The cervical VEMP (cVEMP) and ocular VEMP (oVEMP) are theorized to originate from the saccule and utricle, respectively. Thresholds, defined as the lowest stimulus intensity at which a response is seen, can be obtained at multiple test stimulus frequencies (250, 500, 750, 1000 Hz) and threshold response curves can be constructed. The lowest threshold for eliciting a response is typically seen at 500 Hz for both oVEMP and cVEMP. In hydropic conditions such as Ménière's disease, VEMP thresholds can be elevated or absent at all tested frequencies. Additionally, VEMP tuning curves can be shifted such that the lowest threshold is observed at a different tested frequency (e.g. 750 or 1000 Hz). A shift in resonance frequency of the otolithic organs due to pressure changes in the endolymphatic space is hypothesized to cause these changes.
Successful completion of the aims of this study will afford better understanding of the potential effects of infrasound on inner ear function. The findings of this work will fuel additional investigation of risks of infrasound exposure and may spur efforts to reduce individual and environmental exposure. A newly described mechanism would provide researchers, regulators and advocacy groups with a previously absent and crucial understanding of the effects of infrasound on inner ear function when crafting policy, designing new technologies, and ensuring the safety of exposed individuals
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Block 1
Participants in the cohort will undergo testing in the order of: ECoG, oVEMP, cVEMP
Infrasound exposure
All cohorts will receive an identical infrasound exposure of equal time duration, varying only the order in which the testing is performed. To simulate the frequencies generated by a common source of environmental infrasound (wind turbines), recordings measured at a full-scale research wind turbine at the University of Minnesota will be utilized to create an infrasound stimulus. The resultant sound file consists of the fundamental frequency at approximately 0.7 Hz, equal to the blade passage rate, plus the harmonic overtones of the fundamental frequency. The presentation level is 85 dB SPL. The stimulus will be presented in a sound field.
Block 2
Participants in the cohort will undergo testing in the order of: ECoG, cVEMP, oVEMP
Infrasound exposure
All cohorts will receive an identical infrasound exposure of equal time duration, varying only the order in which the testing is performed. To simulate the frequencies generated by a common source of environmental infrasound (wind turbines), recordings measured at a full-scale research wind turbine at the University of Minnesota will be utilized to create an infrasound stimulus. The resultant sound file consists of the fundamental frequency at approximately 0.7 Hz, equal to the blade passage rate, plus the harmonic overtones of the fundamental frequency. The presentation level is 85 dB SPL. The stimulus will be presented in a sound field.
Block 3
Participants in the cohort will undergo testing in the order of: oVEMP, cVEMP, ECoG
Infrasound exposure
All cohorts will receive an identical infrasound exposure of equal time duration, varying only the order in which the testing is performed. To simulate the frequencies generated by a common source of environmental infrasound (wind turbines), recordings measured at a full-scale research wind turbine at the University of Minnesota will be utilized to create an infrasound stimulus. The resultant sound file consists of the fundamental frequency at approximately 0.7 Hz, equal to the blade passage rate, plus the harmonic overtones of the fundamental frequency. The presentation level is 85 dB SPL. The stimulus will be presented in a sound field.
Block 4
Participants in the cohort will undergo testing in the order of: oVEMP, ECoG, cVEMP
Infrasound exposure
All cohorts will receive an identical infrasound exposure of equal time duration, varying only the order in which the testing is performed. To simulate the frequencies generated by a common source of environmental infrasound (wind turbines), recordings measured at a full-scale research wind turbine at the University of Minnesota will be utilized to create an infrasound stimulus. The resultant sound file consists of the fundamental frequency at approximately 0.7 Hz, equal to the blade passage rate, plus the harmonic overtones of the fundamental frequency. The presentation level is 85 dB SPL. The stimulus will be presented in a sound field.
Block 5
Participants in the cohort will undergo testing in the order of: cVEMP, ECoG, oVEMP
Infrasound exposure
All cohorts will receive an identical infrasound exposure of equal time duration, varying only the order in which the testing is performed. To simulate the frequencies generated by a common source of environmental infrasound (wind turbines), recordings measured at a full-scale research wind turbine at the University of Minnesota will be utilized to create an infrasound stimulus. The resultant sound file consists of the fundamental frequency at approximately 0.7 Hz, equal to the blade passage rate, plus the harmonic overtones of the fundamental frequency. The presentation level is 85 dB SPL. The stimulus will be presented in a sound field.
Block 6
Participants in the cohort will undergo testing in the order of: cVEMP, oVEMP, ECoG
Infrasound exposure
All cohorts will receive an identical infrasound exposure of equal time duration, varying only the order in which the testing is performed. To simulate the frequencies generated by a common source of environmental infrasound (wind turbines), recordings measured at a full-scale research wind turbine at the University of Minnesota will be utilized to create an infrasound stimulus. The resultant sound file consists of the fundamental frequency at approximately 0.7 Hz, equal to the blade passage rate, plus the harmonic overtones of the fundamental frequency. The presentation level is 85 dB SPL. The stimulus will be presented in a sound field.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Infrasound exposure
All cohorts will receive an identical infrasound exposure of equal time duration, varying only the order in which the testing is performed. To simulate the frequencies generated by a common source of environmental infrasound (wind turbines), recordings measured at a full-scale research wind turbine at the University of Minnesota will be utilized to create an infrasound stimulus. The resultant sound file consists of the fundamental frequency at approximately 0.7 Hz, equal to the blade passage rate, plus the harmonic overtones of the fundamental frequency. The presentation level is 85 dB SPL. The stimulus will be presented in a sound field.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Absence of otologic symptoms based on screening questionnaire
3. Normal otoscopic examination
4. Audiometric thresholds less than 25 dB at 250, 500, 750, 1000 Hz.
Exclusion Criteria
2. Presence of any positive symptom on the questionnaire
3. Thresholds greater than 25 dB at the tested frequencies
4. Abnormal otoscopic examination (e.g., ear canal occlusion, tympanic membrane perforation, tympanic membrane retraction)
5. History of prior ear surgery.
18 Years
60 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Minnesota
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Meredith E Adams, MD
Role: PRINCIPAL_INVESTIGATOR
Assistant Professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Minnesota
Minneapolis, Minnesota, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Salt AN, Hullar TE. Responses of the ear to low frequency sounds, infrasound and wind turbines. Hear Res. 2010 Sep 1;268(1-2):12-21. doi: 10.1016/j.heares.2010.06.007. Epub 2010 Jun 16.
Berglund B, Hassmen P, Job RF. Sources and effects of low-frequency noise. J Acoust Soc Am. 1996 May;99(5):2985-3002. doi: 10.1121/1.414863.
Sugimoto T, Koyama K, Kurihara Y, Watanabe K. Measurement of infrasound generated by wind turbine generator. In: Proc. SICE Conf. 2008, pp. 5e8.
Orrell A, Foster N. 2015 Distributed Wind Market Report. U.S. Department of Energy; 2016.
Schmidt JH, Klokker M. Health effects related to wind turbine noise exposure: a systematic review. PLoS One. 2014 Dec 4;9(12):e114183. doi: 10.1371/journal.pone.0114183. eCollection 2014.
Kageyama T, Yano T, Kuwano S, Sueoka S, Tachibana H. Exposure-response relationship of wind turbine noise with self-reported symptoms of sleep and health problems: A nationwide socioacoustic survey in Japan. Noise Health. 2016 Mar-Apr;18(81):53-61. doi: 10.4103/1463-1741.178478.
May M, McMurtry RY. Wind Turbines and Adverse Health Effects: A Second Opinion. J Occup Environ Med. 2015 Oct;57(10):e130-2. doi: 10.1097/JOM.0000000000000447. No abstract available.
McCunney RJ, Mundt KA, Colby WD, Dobie R, Kaliski K, Blais M. Wind turbines and health: a critical review of the scientific literature. J Occup Environ Med. 2014 Nov;56(11):e108-30. doi: 10.1097/JOM.0000000000000313.
Flock A, Flock B. Hydrops in the cochlea can be induced by sound as well as by static pressure. Hear Res. 2000 Dec;150(1-2):175-88. doi: 10.1016/s0378-5955(00)00198-2.
Salt AN. Acute endolymphatic hydrops generated by exposure of the ear to nontraumatic low-frequency tones. J Assoc Res Otolaryngol. 2004 Jun;5(2):203-14. doi: 10.1007/s10162-003-4032-z.
Salt AN, Lichtenhan JT, Gill RM, Hartsock JJ. Large endolymphatic potentials from low-frequency and infrasonic tones in the guinea pig. J Acoust Soc Am. 2013 Mar;133(3):1561-71. doi: 10.1121/1.4789005.
Hensel J, Scholz G, Hurttig U, Mrowinski D, Janssen T. Impact of infrasound on the human cochlea. Hear Res. 2007 Nov;233(1-2):67-76. doi: 10.1016/j.heares.2007.07.004. Epub 2007 Jul 29.
Dommes E, Bauknecht HC, Scholz G, Rothemund Y, Hensel J, Klingebiel R. Auditory cortex stimulation by low-frequency tones-an fMRI study. Brain Res. 2009 Dec 22;1304:129-37. doi: 10.1016/j.brainres.2009.09.089. Epub 2009 Sep 28.
Coats AC. The summating potential and Meniere's disease. I. Summating potential amplitude in Meniere and non-Meniere ears. Arch Otolaryngol. 1981 Apr;107(4):199-208. doi: 10.1001/archotol.1981.00790400001001.
Durrant JD, Dallos P. Modification of DIF summating potential components by stimulus biasing. J Acoust Soc Am. 1974 Aug;56(2):562-70. doi: 10.1121/1.1903291. No abstract available.
Seo YJ, Kim J, Choi JY, Lee WS. Visualization of endolymphatic hydrops and correlation with audio-vestibular functional testing in patients with definite Meniere's disease. Auris Nasus Larynx. 2013 Apr;40(2):167-72. doi: 10.1016/j.anl.2012.07.009. Epub 2012 Aug 4.
Iwasaki S, Smulders YE, Burgess AM, McGarvie LA, Macdougall HG, Halmagyi GM, Curthoys IS. Ocular vestibular evoked myogenic potentials in response to bone-conducted vibration of the midline forehead at Fz. A new indicator of unilateral otolithic loss. Audiol Neurootol. 2008;13(6):396-404. doi: 10.1159/000148203. Epub 2008 Jul 29.
Rauch SD, Zhou G, Kujawa SG, Guinan JJ, Herrmann BS. Vestibular evoked myogenic potentials show altered tuning in patients with Meniere's disease. Otol Neurotol. 2004 May;25(3):333-8. doi: 10.1097/00129492-200405000-00022.
Winters SM, Berg IT, Grolman W, Klis SF. Ocular vestibular evoked myogenic potentials: frequency tuning to air-conducted acoustic stimuli in healthy subjects and Meniere's disease. Audiol Neurootol. 2012;17(1):12-9. doi: 10.1159/000324858. Epub 2011 Apr 29.
Koerner TK, Zhang Y, Nelson PB, Wang B, Zou H. Neural indices of phonemic discrimination and sentence-level speech intelligibility in quiet and noise: A mismatch negativity study. Hear Res. 2016 Sep;339:40-9. doi: 10.1016/j.heares.2016.06.001. Epub 2016 Jun 4.
Leventhall G. What is infrasound? Prog Biophys Mol Biol. 2007 Jan-Apr;93(1-3):130-7. doi: 10.1016/j.pbiomolbio.2006.07.006. Epub 2006 Aug 4.
Duck FA. Medical and non-medical protection standards for ultrasound and infrasound. Prog Biophys Mol Biol. 2007 Jan-Apr;93(1-3):176-91. doi: 10.1016/j.pbiomolbio.2006.07.008. Epub 2006 Aug 4.
Bonucci AS, Hyppolito MA. Comparison of the use of tympanic and extratympanic electrodes for electrocochleography. Laryngoscope. 2009 Mar;119(3):563-6. doi: 10.1002/lary.20105.
Densert B, Arlinger S, Sass K, Hergils L. Reproducibility of the electric response components in clinical electrocochleography. Audiology. 1994 Sep-Oct;33(5):254-63. doi: 10.3109/00206099409071885.
Blakley BW, Wong V. Normal Values for Cervical Vestibular-Evoked Myogenic Potentials. Otol Neurotol. 2015 Jul;36(6):1069-73. doi: 10.1097/MAO.0000000000000752.
Piker EG, Jacobson GP, McCaslin DL, Hood LJ. Normal characteristics of the ocular vestibular evoked myogenic potential. J Am Acad Audiol. 2011 Apr;22(4):222-30. doi: 10.3766/jaaa.22.4.5.
Adams ME, Heidenreich KD, Kileny PR. Audiovestibular testing in patients with Meniere's disease. Otolaryngol Clin North Am. 2010 Oct;43(5):995-1009. doi: 10.1016/j.otc.2010.05.008.
Janky KL, Shepard N. Vestibular evoked myogenic potential (VEMP) testing: normative threshold response curves and effects of age. J Am Acad Audiol. 2009 Sep;20(8):514-22. doi: 10.3766/jaaa.20.8.6.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
1701M04145
Identifier Type: -
Identifier Source: org_study_id
More Related Trials