The Effect of a Walking Assist Robot on Gait Function and Brain Activity in Stroke Patients and Elderly Adults

NCT ID: NCT03048968

Last Updated: 2019-04-29

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

40 participants

Study Classification

INTERVENTIONAL

Study Start Date

2017-03-01

Study Completion Date

2017-10-23

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study was to investigate the effects of the new wearable hip assist robot, gait enhancing and motivating system (GEMS) developed by Samsung Advanced Institute of Technology (Samsung Electronics Co, Ltd., Korea) on gait, sit-to-stand movement and cortical activation in elderly adults and stroke patients.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

In elderly adults,

1. Spatio temporal characteristics, muscle activation and foot pressure distribution are measured by motion capture system (Motion Analysis Corporation, Santa Rosa, CA, USA), surface electromyography (sEMG) (Noraxon Inc., Scottsdale, AZ, USA) and F-Scan Mobile system (Tekscan Inc., South Boston, MA, USA) during 10m walking test.
2. Muscle activation and foot pressure distribution are measured by surface electromyography (sEMG) and F-Scan Mobile system during five times sit-to-stand test.
3. Muscle activation and foot pressure distribution are measured by surface electromyography (sEMG) and F-Scan Mobile system during stair climbing.
4. Cortical activation is measured by functional Near-Infrared-Spectroscopy (fNIRS) (NIRScout, NIRx, Germany) during treadmill gait.

In stroke patients,

1. Muscle activation and foot pressure distribution are measured by surface electromyography (sEMG) and F-Scan Mobile system during five times sit-to-stand test.
2. Cortical activation is measured by functional Near-Infrared-Spectroscopy (fNIRS) (NIRScout, NIRx, Germany) during treadmill gait.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Stroke Healthy

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

study group1: elderly adults

Gait, sit-to-stand movement, stair climbing and treadmill gait with GEMS and without GEMS

Group Type EXPERIMENTAL

Gait, sit-to-stand movement, stair climbing and treadmill gait

Intervention Type PROCEDURE

Spatio temporal characteristics, muscle activation and foot pressure distribution are measured by motion capture system, surface electromyography (sEMG) and F-Scan Mobile system during 10m walking test. Muscle activation and foot pressure distribution are measured by surface electromyography (sEMG) and F-Scan Mobile system during five times sit-to-stand test.Muscle activation and foot pressure distribution are measured by surface electromyography (sEMG) and F-Scan Mobile system during stair climbing. Cortical activation is measured by functional Near-Infrared-Spectroscopy (fNIRS) (NIRScout, NIRx, Germany) during treadmill gait.

gait enhancing mechatronic system (GEMS)

Intervention Type DEVICE

Gait, sit-to-stand movement, stair climbing and treadmill gait with GEMS and without GEMS in elderly adults.

Sit-to-stand movement and treadmill gait with GEMS and without GEMS in stroke patients.

treadmill

Intervention Type DEVICE

Cortical activation is measured by functional Near-Infrared-Spectroscopy (fNIRS) (NIRScout, NIRx, Germany) during treadmill gait.

study group2: stroke patients

Sit-to-stand movement and treadmill gait with GEMS and without GEMS

Group Type EXPERIMENTAL

Sit-to-stand movement and treadmill gait

Intervention Type PROCEDURE

Muscle activation and foot pressure distribution are measured by surface electromyography (sEMG) and F-Scan Mobile system during five times sit-to-stand test. Cortical activation is measured by functional Near-Infrared-Spectroscopy (fNIRS) (NIRScout, NIRx, Germany) during treadmill gait.

gait enhancing mechatronic system (GEMS)

Intervention Type DEVICE

Gait, sit-to-stand movement, stair climbing and treadmill gait with GEMS and without GEMS in elderly adults.

Sit-to-stand movement and treadmill gait with GEMS and without GEMS in stroke patients.

treadmill

Intervention Type DEVICE

Cortical activation is measured by functional Near-Infrared-Spectroscopy (fNIRS) (NIRScout, NIRx, Germany) during treadmill gait.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Gait, sit-to-stand movement, stair climbing and treadmill gait

Spatio temporal characteristics, muscle activation and foot pressure distribution are measured by motion capture system, surface electromyography (sEMG) and F-Scan Mobile system during 10m walking test. Muscle activation and foot pressure distribution are measured by surface electromyography (sEMG) and F-Scan Mobile system during five times sit-to-stand test.Muscle activation and foot pressure distribution are measured by surface electromyography (sEMG) and F-Scan Mobile system during stair climbing. Cortical activation is measured by functional Near-Infrared-Spectroscopy (fNIRS) (NIRScout, NIRx, Germany) during treadmill gait.

Intervention Type PROCEDURE

Sit-to-stand movement and treadmill gait

Muscle activation and foot pressure distribution are measured by surface electromyography (sEMG) and F-Scan Mobile system during five times sit-to-stand test. Cortical activation is measured by functional Near-Infrared-Spectroscopy (fNIRS) (NIRScout, NIRx, Germany) during treadmill gait.

Intervention Type PROCEDURE

gait enhancing mechatronic system (GEMS)

Gait, sit-to-stand movement, stair climbing and treadmill gait with GEMS and without GEMS in elderly adults.

Sit-to-stand movement and treadmill gait with GEMS and without GEMS in stroke patients.

Intervention Type DEVICE

treadmill

Cortical activation is measured by functional Near-Infrared-Spectroscopy (fNIRS) (NIRScout, NIRx, Germany) during treadmill gait.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Elderly adults

1. Age: between 65 and 84 years
2. elderly adults who had no neurological or musculoskeletal abnormalities affecting gait
3. Ability to walk at least 10m regardless of assist devices
* Stroke

1. Age: between 20 and 84 years
2. ≥ 3 months post stroke
3. Ability to walk at least 10m regardless of assist devices
4. Adequate gait function (FAC \> 3)
5. Physician approval for patient participation

Exclusion Criteria

* Elderly adults

1. History of any diseases (eg. lower extremity orthopedic diseases, neurologic disorders, cardiovascular disease, heart failure, uncontrolled hypertension that affect walking capacity, efficiency, and endurance)
2. Severe visual impairment or dizziness that increases the risk of falls
* Stroke

1. Serious cardiac conditions (hospitalization for myocardial infarction or heart surgery within 3 months, history of congestive heart failure, documented serious and unstable cardiac arrhythmias, hypertrophic cardiomyopathy, severe aortic stenosis, angina or dyspnea at rest or during activities of daily living)
2. Advanced liver, kidney, cardiac, or pulmonary disease
3. History of concussion in last 6 months
4. History of unexplained, recurring headaches, epilepsy/seizures/skull fractures or skull deficits
5. Preexisting neurological disorders such as Parkinson's disease, Amyotrophic Lateral Sclerosis (ALS), Multiple Sclerosis (MS), dementia
Minimum Eligible Age

20 Years

Maximum Eligible Age

84 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Samsung Electronics

INDUSTRY

Sponsor Role collaborator

Samsung Medical Center

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Yun-Hee Kim

Professor, MD, PhD

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Yun-Hee Kim

Role: STUDY_CHAIR

Samsung Medical Center

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Samsung Medical Center

Seoul, , South Korea

Site Status

Countries

Review the countries where the study has at least one active or historical site.

South Korea

References

Explore related publications, articles, or registry entries linked to this study.

Lee SH, Lee HJ, Shim Y, Chang WH, Choi BO, Ryu GH, Kim YH. Wearable hip-assist robot modulates cortical activation during gait in stroke patients: a functional near-infrared spectroscopy study. J Neuroeng Rehabil. 2020 Oct 29;17(1):145. doi: 10.1186/s12984-020-00777-0.

Reference Type DERIVED
PMID: 33121535 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2016-07-093

Identifier Type: -

Identifier Source: org_study_id