Comparing Two Methods of Contractions Monitoring for Clinical Decision Making Regarding Treatment Among Pregnant Women With Preterm Contractions.
NCT ID: NCT02875418
Last Updated: 2016-08-23
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
PHASE3
1500 participants
INTERVENTIONAL
2016-09-30
2019-09-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Identification and measurement of uterine contractions throughout pregnancy and labor is crucial to the well being of both mother and fetus. Prematurity is one of the major causes for adverse pregnancy outcomes, and clinical decision-making often relies on uterine frequency as recorded by a tocodynamometer, as well as on other methods including sonographic cervical length, pelvic examination.
Objective:
To show that the use of the EUM in preterm labor is effective in establishing true preterm labor.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Accuracy and Reliability of Fetal Heart Rate and Uterine Contraction Monitoring Method
NCT01280357
Electrical Inhibition of Human Preterm Contractions
NCT02983240
Multi-Reader Multi-Case Study to Identify Uterine Contractions Recorded From Laboring Patients by Practicing Clinicians
NCT01282723
Multi-Reader Multi-Case Study to Identify Uterine Contractions Recorded From Laboring and Nonlaboring Patients by Practicing Clinicians
NCT01730963
Multichannel EMG Diagnosing True Preterm Labor
NCT03785795
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Currently, three methods of assessing uterine activity exist. The first, tocodynamometry, is based on mechanical measurement of abdominal wall stiffness by a strain gauge placed externally on the patient's abdomen. This method mainly displays the presence of a contraction, its duration and the frequency of contractions. Yet, it fails to reflect the actual quantity of baseline tone or contraction amplitude due to great variability in placement and the gravida's body habitus. It is also unable to distinguish between true contractions or maternal movements or maternal Valsalva maneuver such as in coughing, straining or sneezing. These are the main reasons this technology is known to be unreliable in many cases and shows high percentage of false positive and false negative results \[1\].
Another method for monitoring uterine contractions is an internal measurement of uterine pressure via an Intra-Uterine Pressure Catheter (IUPC). While it is accurate in recording intensity, duration and frequency of contractions, as well as uterine basal tone, it has two principle limitations: the IUPC can only be used after rupture of the membranes, and the introduction of a foreign object in the uterine cavity may result in chorioamnionitis.
The third method of evaluating uterine activity involves recording of the myometrial electrical activity \[2\]. Initially, this was assessed in animal models by means of invasive uterine EMG \[3-6\], followed by noninvasive EMG recordings from abdominal surface in humans \[7-10\]. Several studies have attempted to correlate between term and preterm labor to uterine EMG, with limited success \[11-17\]. However, although most traditional EMG devices use only 2 electrodes, a multichannel, noninvasive EMG device have been used successfully in previous studies, both in preterm and term pregnancies, and were proved as both safe and accurate \[18-25\]. Recently, reliability studies were published, regarding the comparison to tocodynamomtery, IUPC and electrical uterine monitoring, using a multichannel EMG, and demonstrated the multichannel EMG is as good as the IUPC ('Gold Standard') and both multichannel EMG and IUPC are superior to tocodynamometry in recording uterine activity \[26-27\].
Study rational Premature labor and delivery heralds great costs to the healthcare system, including admission costs, tocolytic treatment and side effects and neonatal treatment of the preterm neonate. Unfortunately, the accuracy of diagnosing preterm labor is poor, with less than 10% of women presenting with preterm labor symptoms actually delivering within 7 days of symptoms' onset \[28\], 30% with resolving symptoms and more than 50% delivering at term \[29\]. Since IUPC cannot be used in women with intact membranes and tocodynamometry is unreliable, with previous reports concluding that multichannel EMG is superior to tocodynamomtery and comparable to IUPC, our objective is to evaluate the utility of the multichannel EMG in women with preterm contractions.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
EUM and tocodynamometry
Pregnant women with gestational age 24+0/7 to 33+6/7 weeks of gestation and contractions, cramping, pelvic pressure or backache.
EUM
STUDY DESIGN
1. Explanation regarding the study and assessing eligibility criteria.
2. Signing an informed consent.
3. Recording of uterine contractions by both EUM and tocodynamometry. A correlation between EUM and tocodynamometry will be calculated. For the purpose of this study, a positive EUM or tocodynamometry will be defined as 3 at least 3 contractions in 30 minutes.
Tocodynamometry
STUDY DESIGN
1. Explanation regarding the study and assessing eligibility criteria.
2. Signing an informed consent.
3. Recording of uterine contractions by both EUM and tocodynamometry. A correlation between EUM and tocodynamometry will be calculated. For the purpose of this study, a positive EUM or tocodynamometry will be defined as 3 at least 3 contractions in 30 minutes.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
EUM
STUDY DESIGN
1. Explanation regarding the study and assessing eligibility criteria.
2. Signing an informed consent.
3. Recording of uterine contractions by both EUM and tocodynamometry. A correlation between EUM and tocodynamometry will be calculated. For the purpose of this study, a positive EUM or tocodynamometry will be defined as 3 at least 3 contractions in 30 minutes.
Tocodynamometry
STUDY DESIGN
1. Explanation regarding the study and assessing eligibility criteria.
2. Signing an informed consent.
3. Recording of uterine contractions by both EUM and tocodynamometry. A correlation between EUM and tocodynamometry will be calculated. For the purpose of this study, a positive EUM or tocodynamometry will be defined as 3 at least 3 contractions in 30 minutes.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Maternal age \> 18 years.
3. Contractions, cramping, pelvic pressure or backache.
4. Reactive fetal heart rate monitoring at enrollment.
5. Subjects are willing and able to comply with the requirements of the protocol.
6. Fully understand all elements of the study, and have signed and dated, the written informed consent form before initiation of protocol-specified procedures.
Exclusion Criteria
2. Maternal age \< 18 years.
3. Woman with implanted electronic device of any kind.
4. Woman with allergy to silver.
5. Irritated skin or open wound.
18 Years
FEMALE
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Tel-Aviv Sourasky Medical Center
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
yariv yogev, professor
Role: PRINCIPAL_INVESTIGATOR
Tel Aviv Medical Center
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
171-16-TLV
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.