Feasibility of Electromagnetic Acoustic Imaging of Liver Tumours
NCT ID: NCT02827786
Last Updated: 2016-07-11
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
30 participants
INTERVENTIONAL
2016-09-30
2017-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
A Trial on Contrast-enhanced Ultrasound Versus Conventional Ultrasound Guided Biopsy of Liver Neoplasms
NCT02413437
ShearWave™ Elastography of Breast Lesions in Chinese Patients
NCT02226081
Feasibility of Multi-Energy Digital Radiography Detector for Lung Lesions Detection
NCT03528733
The Effectiveness and Safety of Electromagnetic Navigation Real-time Guided Percutaneous Lung Biopsy
NCT05799014
The Development of Quantitative Ultrasound Imaging Software Platform
NCT05836246
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Target lesions and background liver to be studied include:
1. Malignant tumours (metastases (adenocarcinomas and neuroendocrine tumours) and primary hepatic malignancy)
2. Benign tumours (haemangiomas, focal nodular hyperplasia and adenomas)
3. Background liver (remote from target lesion), both normal and fatty liver parenchyma will be included.
Participants must meet the strict inclusion/exclusion criteria for study participation.
Enrollment
1. Patients referred for medical imaging at Sunnybrook Health Sciences Centre and have imaging findings consistent with focal hepatic lesion(s) on conventional US, CECT and/or MRI, characteristic of a specific hepatic tumour (benign or malignant), greater than 1.5cm in size and located within a portion of the liver readily amenable to US assessment. An abdominal radiologist and/or surgical oncologist will identify patients. Recruitment will occur prior to baseline imaging (at time of imaging requisition receipt) or immediately following baseline imaging, either by the study coordinator or surgical oncologist.
2. Patients referred for imaged guided percutaneous biopsy of a focal liver lesion will also be identified and recruited in advance of their biopsy appointment/intervention, either by the study coordinator or referring surgical oncologist (at time of receiving or requesting biopsy respectively).
3. In all cases the responsible physician for the patient will be informed of the intent of the participant, in advance of EMA imaging, thus ensuring recruitment occurs within the circle of care.
Imaging
All EMA imaging will be performed using an investigational EMA device/system, located within the Department of Medical Imaging, Sunnybrook Health Sciences Centre.
Informed consent will be obtained at time of study enrollment, but re-confirmed at time of the EMA study.
Pre-determined target liver lesion(s) (based on baseline diagnostic CT, US or MRI) will be reviewed by an experienced board certified radiologist. Target lesion will be initially evaluated with conventional b-mode US imaging to identify lesion location, size and morphology. Technical feasibility of EMA imaging will be evaluated (imaging window, adequate breath hold etc).
Target lesion will be imaged in two planes (sagittal and transverse) with b-mode, with up to two target lesions assessed per patient. One focal site of background liver parenchyma will also be assessed, remote from the target lesion.
Grey-scale tissue characteristics will be recorded of the target and background parenchyma, including target size, location, and morphology with lesion assigned a conspicuity score by the operator.
EMA imaging will be performed using a dedicated experimental EMA system. Imaging of the pre-determined target lesion(s) and background liver parenchyma will be acquired (see detailed EMA imaging technique below), on a single plane with pre-set region of interest. Qualitative and quantitative parameters will be recorded/stored on the imaging system.
No oral or intravenous contrast agents will be used during this EMA study. Standard or modified ultrasound coupling gel will be used routinely as per standard clinical practice.
Integration with Standard Treatment of Liver Cancer Conventional US together with EMA imaging will be the only additional test/intervention performed as part of this study that are not routinely done for the study population.
Patients will receive standard work-up, treatment and follow-up for their liver lesion(s) according to clinical guidelines and institutional policies. Management and/or treatment will not be modified based on the results of this study.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Electromagnetic Acoustic Imaging
Electromagnetic Acoustic Imaging
Electromagnetic Acoustic imaging (EMA) is a novel experimental platform utilizing the combination of electromagnetic radio frequency (RF) and acoustic waves to enhance ultrasound images. The resultant imaging allows (based on early experimental models) tissue differentiation based on its mechanical and electrical properties. Combined with conventional US scanning, this technology potentially allows high spatial resolution imaging of a target tissue with superimposed high contrast functional information. This is a proof-of-concept pilot study in humans.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Electromagnetic Acoustic Imaging
Electromagnetic Acoustic imaging (EMA) is a novel experimental platform utilizing the combination of electromagnetic radio frequency (RF) and acoustic waves to enhance ultrasound images. The resultant imaging allows (based on early experimental models) tissue differentiation based on its mechanical and electrical properties. Combined with conventional US scanning, this technology potentially allows high spatial resolution imaging of a target tissue with superimposed high contrast functional information. This is a proof-of-concept pilot study in humans.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Focal liver lesion ≥ 1.5cm
3. Pre-determined focal liver lesion in location likely easily visible on US
4. Ability to provide written informed consent to participate in the study
Exclusion Criteria
2. Cardiac pacemaker implanted cardioverter- defibrillator, neuro-stimulation system, hepatobiliary metallic foreign body or tattoo at proposed site of imaging.
3. Indeterminate focal liver lesion by conventional US, CT and/or MRI imaging and without the prospect of histopathological assessment of lesion(s)
4. Local and/or systemic treatment related to focal liver lesion, prior to EMA imaging.
5. Inability to obtain imaging and/or acceptable quality of grey-scale and/or EMA imaging
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Sunnybrook Health Sciences Centre
OTHER
Enhanced Medical
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Chirag Patel, MD
Role: PRINCIPAL_INVESTIGATOR
Sunnybrook Health Sciences Centre
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Sunnybrook Health Sciences Centre
Toronto, Ontario, Canada
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
EMASunnybrook1
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.