The Application of Multichannel ECG Analytic System in Cardiovascular Diseases

NCT ID: NCT02814396

Last Updated: 2024-09-19

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

5000 participants

Study Classification

OBSERVATIONAL

Study Start Date

2013-01-31

Study Completion Date

2024-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Cardiovascular disease (CVD) is the leading cause of death worldwide. Most individuals with CVD show no evidence of disease for decades as the disease progresses before the first onset of symptoms, often a "sudden" heart attack, finally arises. The spatial repolarization heterogeneity within the ventricular myocardium had been proposed to represent the function of the heart in health and disease. Greater than normal levels of repolarization dispersion may allow early diagnosis of CVD. There is a growing interest in the characteristic features of ventricular repolarization that leads to lethal ventricular arrhythmia even with the use of non-antiarrhythmic drugs. The recovery time dispersion may reflect a repolarization heterogeneity leading to lethal ventricular arrhythmia. Previously, the investigators had utilized a 64-channel low-TC SQUID MCG device to develop and verify 2 parameters, so called smooth index of QTc (SIQTc) and T wave propagation (TWP), to accurately detect and localize the myocardial ischemia. Recently Nakai, et al. reported that a newly developed 187-ch signal-averaged vector-projected ECG (187-ch SAVP-ECG) could evaluate low-amplitude high-frequency potentials and repolarization heterogeneity. In this project, the investigators'll try to modify and improve the spatial resolution of ECG signals from a Self-built-in multichannel ECG system with a newly developed algorithm, and also try to derive the SIQTc and TWP from this system, for early detection of CVD. The investigators intend to prove the concept that this newly developed multichannel ECG system could efficiently detect or diagnose CVD with acceptable sensitivity and specificity, and in a portable way.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Cardiovascular disease (CVD) is the leading cause of death worldwide. Most individuals with CVD show no evidence of disease for decades as the disease progresses before the first onset of symptoms, often a "sudden" heart attack, finally arises. The spatial repolarization heterogeneity within the ventricular myocardium had been proposed to represent the function of the heart in health and disease. Greater than normal levels of repolarization dispersion may allow early diagnosis of CVD. There is a growing interest in the characteristic features of ventricular repolarization that leads to lethal ventricular arrhythmia even with the use of non-antiarrhythmic drugs. The recovery time dispersion may reflect a repolarization heterogeneity leading to lethal ventricular arrhythmia. Although cheap and convenient, the traditional 12-leads electrocardiogram (ECG) is frequently normal at rest in such patients. The quantification of repolarization heterogeneity with ECG, QT dispersion, has some methodological limitations and has been abandoned in daily practice. Many studies have shown that body surface potential mapping (BSPM) contains more diagnostic and prognostic information than that elicited from a 12-lead ECG. The BSPM and magnetocardiogram (MCG) are two new developed recording methods, and provide higher spatial resolution than traditional ECG signals but with the disadvantages of high cost and huge volume. It is impossible to be used in a portable way. Previously, the investigators had utilized a 64-channel low-TC SQUID MCG device to develop and verify 2 parameters, so called smooth index of QTc (SIQTc) and T wave propagation (TWP), to accurately detect and localize the myocardial ischemia. Recently Nakai, et al. reported that a newly developed 187-ch signal-averaged vector-projected ECG (187-ch SAVP-ECG) could evaluate low-amplitude high-frequency potentials and repolarization heterogeneity. In this project, the investigators'll try to modify and improve the spatial resolution of ECG signals from a Self-built-in multichannel ECG system with a newly developed algorithm, and also try to derive the SIQTc and TWP from this system, for early detection of CVD. The investigators intend to prove the concept that this newly developed multichannel ECG system could efficiently detect or diagnose CVD with acceptable sensitivity and specificity, and in a portable way.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Multichannel ECG System

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_ONLY

Study Time Perspective

PROSPECTIVE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients older than 20 years old.
* with suspected arrhythmia or cardiovascular diseases.

Exclusion Criteria

* NO
Minimum Eligible Age

20 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Taiwan University Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Chau C WU, M.D.,Ph.D.

Role: PRINCIPAL_INVESTIGATOR

[email protected]

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

NTUH

Taipei, , Taiwan

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Taiwan

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Chau C Wu, M.D.,Ph.D.

Role: CONTACT

886-2-23123456 ext. 88560

Wan T Ke

Role: CONTACT

886-223123456 ext. 88558

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

chau C Wu, Ph.D, MD

Role: primary

886-2-23123456 ext. 88560

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

201207070RIC

Identifier Type: -