Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
15 participants
INTERVENTIONAL
2015-06-30
2016-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Breath Analysis of Patients Diagnosed With COVID-19 Using Infrared Spectroscopy
NCT04867213
Prolonged Hypoxic Breathing in Healthy Volunteers: a Safety Study
NCT02860975
Preoxygenation Using THRIVE Versus Facemask in Parturients
NCT03772574
Mask Hypoxia in Subjects Using Masks to Prevent Infection Spread
NCT04670484
The Effect of Wearing Masks on End-tidal Carbon Dioxide and Pulse Oximetry
NCT05114993
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The military gas mask is part of the respirator classification but owes its specific features. Conventionally, the military gas mask covers a large spectrum of protection aspects and matched with their specific canisters. Consequently, gas masks are usually studied separately from other respirators and Self-Contained Breathing Apparatus (SBCA).
The gas mask design and its components may lead to these respiratory load issues. At rest and effort, what would be the impacts for the work of breathing and gas exchange? In order to avoid hypoxemia and hyperoxia, what would be the optimal means to restore proper oxygenation? We hypothesised: i. on a heightened WOB and the respiratory demands related to wear of the gas mask; ii. An occurrence of hypoxemia will be manifesting during a continuous period at both at rest and effort.
Our goal was to measure the impact of the work of breathing and the gas exchange for a gas mask user. We also measured what was the optimal means for correcting the hypoxemia with a subject.
14 Male Human Subjects participated in a comparison and single-blind randomized experimental study. That was approved by the Ethical Review Committee. All male subjects were in averaged age of 38.9±5 year old and a FEV1 4.60±0.70 Liter. A written consent was obtained for all the subjects prior their acceptance. No rejection happened during the recruiting. The eligibility criteria were: i. No significant cardiac and respiratory diseases known; ii. No epilepsy background; iii. No severe pathology requiring medication; iv. No pregnancy for woman; v. Face medium - size in relation of the gas mask. The exclusion criteria were: i. Refusals relate to wear the oesophageal catheter and for capillary punctures; ii. Claustrophobia; iii. Oesophageal wounds backgrounds; iv. No coronary background and stroke history; v. No face morphology incompatibility with the mask. Spirometry and usual health screening was also done before starting the clinical trial.
Design comprised seven 10-minute testing conditions split in two parts. Five were at rest and sitting on a chair: i. Baseline without gas mask; ii. Baseline with gas mask; iii. Hypoxemia without mask; iv. Hypoxemia with gas mask; and v. Hypoxemia corrected. Two effort conditions were programmed at 7 METS Effort Zone and were performed on Treadmill (Constant 3 MPH speed and 10% inclination). These were with and without the gas mask. Between the rest-condition a 5-minute wash-out took place while for the effort a ten-minute was applied.
Three five-minute periods was followed to record blood pressure and pulse during the conditions. SpO2 was continuously measured with Free O2 during condition while the Massimo was employed also at the beginning both the inclusion and at the each three hypoxemia condition (Radical - Signal Extraction Pulse Oximeter). During effort, they were taken at each two-minute, starting at a zero starting point. Capillary punctures were done at the end of each condition.
Our main measurements were the WOB performed with a continuous recording of Peso pressure and respiratory volumes. Software Acknowledge, version 3.9 served as acquisition data system and analysis were achieved with a 4.2 version and a free-trial WOB calculus system, named RESPMAT. That was obtained from Maynaud and al. \[2\]. As power source, we used a BIOPAC (MP100, Santa Barbara, Californie, USA, 200 Hertz), four differential sensors (Validyne : 1x MP45±100 cmH2O; 2x MP??±5 cmH2O; 1x MP100±100 cmH2O) and four Carrier D-Modulators (Validyne, CT-15,120 Volt, 60 Hertz, 5Watts, Model CD15-A-2-A-1).
Single esophageal catheter (Type Cooper, French caliber #5) and disposable pneumotachs were used. Lidocain spray and K-Y gel were applied during the insertion of the catheter. Its placement was done at 37.6±5.7 cm across the subject and a Mueller test was performed for each subject. In regard of spontaneous breathing, an Hudson mask was used while a C-4 Gas Mask with a canister was employed (Manufacturer: Airboss Defence, Bromont, Canada). Hypoxemia mixture was home-design with usual nitrous and medical gas and maintaining a FiO2 target at 14%. Prototyped Free O2 System was employed for the correction of the hypoxemia.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
SINGLE_GROUP
HEALTH_SERVICES_RESEARCH
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Baseline
Randomised baseline without and with gas mask.
Gas mask
During the conditions that involved a gas mask, the measurement of the work of breathing is achieved with a oesophageal catheter and two disposable pneumotachs. While the oesophageal catheter has been fixed to the mandibular with an hypo-allergic tape, the two pneumotachs are hooked respectively on the canister and exhalation port of the gas mask. Investigators have induced the hypoxemia with a mixture nitreous and medical gas in a plastic bag that has been setted up to the canister. The FiO2 level has been kept to 14 percent.
measurement of the work of breathing
We have been evaluating breathing patterns, index of respiratory efforts and blood gases in all randomized conditions. A gas mask has been used mask (C4, Airboss Defence, Bromont, Canada).
Airway pressure, inspiratory and expiratory flows have been measured. An esophageal catheter has been introduced at the beginning of the study to measure esophageal pressure (Peso) and calculate indexes of respiratory effort (PTPeso, WOB). SpO2 has been continuously measured and capillary blood bases were drawn at the end of each condition. Each condition lasted 10 minutes, data of the last 2 minutes at a steady state has been considered for analyses.
Induced Hypoxemia
Randomised hypoxemia: i. without gas mask; ii. with gas mask; and iii. correction with FreeO2 and gas mask.
Gas mask
During the conditions that involved a gas mask, the measurement of the work of breathing is achieved with a oesophageal catheter and two disposable pneumotachs. While the oesophageal catheter has been fixed to the mandibular with an hypo-allergic tape, the two pneumotachs are hooked respectively on the canister and exhalation port of the gas mask. Investigators have induced the hypoxemia with a mixture nitreous and medical gas in a plastic bag that has been setted up to the canister. The FiO2 level has been kept to 14 percent.
measurement of the work of breathing
We have been evaluating breathing patterns, index of respiratory efforts and blood gases in all randomized conditions. A gas mask has been used mask (C4, Airboss Defence, Bromont, Canada).
Airway pressure, inspiratory and expiratory flows have been measured. An esophageal catheter has been introduced at the beginning of the study to measure esophageal pressure (Peso) and calculate indexes of respiratory effort (PTPeso, WOB). SpO2 has been continuously measured and capillary blood bases were drawn at the end of each condition. Each condition lasted 10 minutes, data of the last 2 minutes at a steady state has been considered for analyses.
Effort
Randomised effort without and with gas mask
Gas mask
During the conditions that involved a gas mask, the measurement of the work of breathing is achieved with a oesophageal catheter and two disposable pneumotachs. While the oesophageal catheter has been fixed to the mandibular with an hypo-allergic tape, the two pneumotachs are hooked respectively on the canister and exhalation port of the gas mask. Investigators have induced the hypoxemia with a mixture nitreous and medical gas in a plastic bag that has been setted up to the canister. The FiO2 level has been kept to 14 percent.
measurement of the work of breathing
We have been evaluating breathing patterns, index of respiratory efforts and blood gases in all randomized conditions. A gas mask has been used mask (C4, Airboss Defence, Bromont, Canada).
Airway pressure, inspiratory and expiratory flows have been measured. An esophageal catheter has been introduced at the beginning of the study to measure esophageal pressure (Peso) and calculate indexes of respiratory effort (PTPeso, WOB). SpO2 has been continuously measured and capillary blood bases were drawn at the end of each condition. Each condition lasted 10 minutes, data of the last 2 minutes at a steady state has been considered for analyses.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Gas mask
During the conditions that involved a gas mask, the measurement of the work of breathing is achieved with a oesophageal catheter and two disposable pneumotachs. While the oesophageal catheter has been fixed to the mandibular with an hypo-allergic tape, the two pneumotachs are hooked respectively on the canister and exhalation port of the gas mask. Investigators have induced the hypoxemia with a mixture nitreous and medical gas in a plastic bag that has been setted up to the canister. The FiO2 level has been kept to 14 percent.
measurement of the work of breathing
We have been evaluating breathing patterns, index of respiratory efforts and blood gases in all randomized conditions. A gas mask has been used mask (C4, Airboss Defence, Bromont, Canada).
Airway pressure, inspiratory and expiratory flows have been measured. An esophageal catheter has been introduced at the beginning of the study to measure esophageal pressure (Peso) and calculate indexes of respiratory effort (PTPeso, WOB). SpO2 has been continuously measured and capillary blood bases were drawn at the end of each condition. Each condition lasted 10 minutes, data of the last 2 minutes at a steady state has been considered for analyses.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Having no history of epilepsy
* Having no severe and chronic pathology that requires medication
* Not being pregnant
* Face size: medium
Exclusion
* Refuse to participate in the study for one of the following reasons: i. wearing a oesophageal catheter; ii. wearing the gas mask; iii. giving blood sample; iv. claustrophobia.
* Oesophageal background wounds
* Facial anthropometrical issues.
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Pierre-Alexandre Bouchard, RT.
UNKNOWN
Captain (Ret) Stephane Bourassa, RN.
UNKNOWN
Laval University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
François Lellouche
Physician
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Francois Lellouche, Doctorate
Role: PRINCIPAL_INVESTIGATOR
Institut de Recherche Universitaire de Cardiologie et Pneumologie de Québec
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Institut de recheche universitaire de cardiologie et pneumologie de Québec
Québec, Quebec, Canada
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Bourassa S, Bouchard PA, Dauphin M, Lellouche F. Oxygen Conservation Methods With Automated Titration. Respir Care. 2020 Oct;65(10):1433-1442. doi: 10.4187/respcare.07240. Epub 2020 Feb 18.
Bourassa S, Bouchard PA, Lellouche F. Impact of Gas Masks on Work of Breathing, Breathing Patterns, and Gas Exchange in Healthy Subjects. Respir Care. 2018 Nov;63(11):1350-1359. doi: 10.4187/respcare.06027. Epub 2018 Jul 31.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2015-2448
Identifier Type: OTHER
Identifier Source: secondary_id
21140
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.