Efficacy Study of the Draeger Jaundice Meter (JM-105) in Neonates of ≥ 24 Weeks of Gestational Age

NCT ID: NCT02774434

Last Updated: 2019-02-07

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

464 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-11-30

Study Completion Date

2018-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The Canadian Pediatric Society recently published guidelines to monitor bilirubin levels and as part of standard of care all hospitalized newborns are routinely monitored for the development of high bilirubin or jaundice every 8-12 hours. One device approved and used in both Canada and the United States is the Draeger Jaundice Meter JM-103, a non-invasive medical device. It has been proven to be effective in patients \>35 weeks gestational age. Recently the JM-103 has been upgraded to include a bigger touch screen, greater storage and functionality. The rest of the features of the JM-103 and JM-105 are identical. In order to test the accuracy of the JM-105 neonates from ≥ 24 weeks gestational age who have or have not undergone phototherapy will be prospectively monitored for transcutaneous bilirubin (TcB) using the JM-105. The measurements will be compared to a physician-ordered total serum bilirubin (TSB).

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Hyperbilirubinemia is a condition that occurs in newborns when there is too much bilirubin in the blood. It is the most common cause of newborns being readmitted to the hospital. It may be harmless or harmful depending on what the cause is and how bad it is. The serum level of bilirubin required for jaundice varies with infants skin tones and body region, however jaundice usually becomes visible in the white part of the eye at smaller levels. Although jaundice in newborn is generally not harmful, it is important to monitor newborns to identify those that are at risk of developing a neurological dysfunction from high bilirubin levels. As part of standard of care all hospitalized newborns are routinely monitored for the development of jaundice by nursing staff and physicians every 8-12 hours. Although jaundice in newborns can usually be detected by lightening/whitening in the skin with digital pressure, this method of visual estimation is very inaccurate and unreliable. Transcutaneous bilirubin measurements are non-invasive and has proven to be equivalent to total serum bilirubin measurements. The JM-103 has been proven to be an effective TcB measure in ethnically diverse populations for patients \>35 weeks gestational age. The JM-105 has been upgraded from the JM-103 with greater efficiency and accuracy. The basic function is the same but has been improved with a larger touch screen, data storage and transmission functionality.

This prospective multi-centre study will be conducted to determine the diagnostic accuracy and performance of the use of the JM-105 in providing transcutaneous bilirubin measurements to estimate serum total bilirubin in neonates ≥ 24 weeks of gestational age who have or have not undergone phototherapy. The study will compare each of the measurements of transcutaneous bilirubin (TcB) obtained for 10 days via the JM-105 device with a neonatology team-ordered series of serum total bilirubin (TSB) measured by high-performance liquid chromatography.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Hyperbilirubinemia Neonatal Jaundice

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

SCREENING

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

JM-105

Within 15 minutes of each ordered blood sample 2 TcB measurements will be performed using the JM-105 on the sternum and forehead. Subject's participation will end after a 10 day period.

Group Type EXPERIMENTAL

JM-105

Intervention Type DEVICE

Measurement of TcB via the JM-105 device

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

JM-105

Measurement of TcB via the JM-105 device

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* The subject is a neonate ≥24 weeks of gestational age for whom a course of phototherapy has not started, is in progress or has been completed
* The subject's routine management includes TSB evaluations
* The subject's family are willing and able to participate in baseline and TSB measurements over 10 days
* Written informed consent to participate in the study has been provided by the subject or legal representative (parent or legal guardian in a clinical study involving children)

Exclusion Criteria

* The subject has Hydrops fetalis
* The subject has major congenital malformations, diseases or skin conditions or thickness that, in the opinion of the investigator would preclude or interfere with the use of the JM-105
Minimum Eligible Age

24 Weeks

Maximum Eligible Age

40 Weeks

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Draeger Medical Systems, Inc.

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Michael Sgro, MD

Role: PRINCIPAL_INVESTIGATOR

Unity Health Toronto

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Saint Michael's Hospital

Toronto, Ontario, Canada

Site Status

Mount Sinai Hospital

Toronto, Ontario, Canada

Site Status

Hamilton Health Science Centre

Toronto, Ontario, Canada

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Canada

References

Explore related publications, articles, or registry entries linked to this study.

Jegathesan T, Campbell DM, Ray JG, Shah V, Berger H, Hayeems RZ, Sgro M; NeoHBC. Transcutaneous versus Total Serum Bilirubin Measurements in Preterm Infants. Neonatology. 2021;118(4):443-453. doi: 10.1159/000516648. Epub 2021 Jun 17.

Reference Type DERIVED
PMID: 34139689 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

JM-105 Study

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Transcutaneous Bilirubinometry and Phototherapy
NCT04246229 NOT_YET_RECRUITING NA
Value of Transcutaneous Bilirubin Devices
NCT06232174 NOT_YET_RECRUITING