Transcranial Magnetic Stimulation for Epilepsy

NCT ID: NCT02757547

Last Updated: 2020-07-23

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

TERMINATED

Clinical Phase

NA

Total Enrollment

2 participants

Study Classification

INTERVENTIONAL

Study Start Date

2015-09-30

Study Completion Date

2017-11-15

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The goal of the present clinical trial is to determine whether low frequency (0.5 Hz) rTMS can induce long term depression in epileptogenic cortex and thus suppress cortical excitability at the epileptic focus.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Investigators propose a safety and feasibility trial for treating epilepsy (Transcranial Magnetic Stimulation for Epilepsy. Principal Investigator: Robert Fisher, MD, PhD, Stanford University). In this approach, the cortical source of epileptic discharges is first localized with dense array electroencephalography (256-channel dEEG). This localization is then registered with neuronavigator software to allow precise targeting with slow (0. 5 Hz) repetitive Transcranial Magnetic Stimulation (rTMS) with the STM9000. The purpose in the feasibility study is to introduce Long Term Depression (LTD) of the seizure onset zone in order to reduce epileptiform discharges. The goal in the future pivotal trial will be to extend this approach to suppress seizures. The funds for this trial are provided by Stanford University. A loan of dEEG equipment and consulting are provided by Electrical Geodesics, Inc. (EGI). EGI seeks FDA's approval for this trial. EGI is the manufacturer of the dEEG system (GES 400) and the US distributor of the EB Neuro STM9000 rTMS system (manufactured in Italy by EB Neuro, S.p.A.).

The eventual goal will be a pivotal trial for a de novo 510k for dEEG-guided rTMS for suppressing epileptic seizures. The more limited goal of suppressing epileptic discharges (spikes) will allow careful evaluation of safety while demonstrating feasibility of the therapeutic action. In preparing this request, the investigators have studied the guidance on the special controls described for rTMS in the FDA Class II Special Controls Guidance Document: Repetitive Transcranial Magnetic Stimulation (rTMS) Systems, Document issued on: July 26, 2011. In addition, because patients with epilepsy are at particular risk of seizures that may be induced or exacerbated by rTMS, investigators also address the unique risks of this population, the existing evidence on safety and efficacy of rTMS treatment of the epileptic focus, and the mitigation the investigators propose to minimize the risks.

EGI has received an IDE for a safety and feasibility trial for treating epileptic discharges with a different method and device, the Geodesic Transcranial Electrical Neuromodulation (GTEN 100) system. The primary difference in the present proposal is the use of rTMS (instead of the GTEN 100) to induce long term depression and thus suppression of the cortical excitability at the epileptic focus. Dr. Robert Fisher, the Principal Investigator on this project, is EGI's unpaid consultant. Dr. Fisher has received an IRB approval at Stanford University Hospital for the larger study with this title for 10 patients with dEEG-guided rTMS treatment of focal epilepsy with the GES 400 and STM9000. The present trial is a safety and feasibility study with 10 patients that will be conducted with an informed consent form that is now specific to this safety and feasibility study.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Epilepsy

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Primary Study Purpose

TREATMENT

Blinding Strategy

QUADRUPLE

Participants Caregivers Investigators Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Transcranial magnetic stimulation - Placebo Arm

A placebo TMS coil is used.

Group Type PLACEBO_COMPARATOR

Transcranial magnetic stimulation - Placebo Arm

Intervention Type DEVICE

Each seizure patient (subject) will receive 5 days in a row the placebo (sham) magnetic stimulation using the placebo (sham) coil of the STM9000 Transcranial Magnetic Stimulator. This involves magnetic stimulation at 90% of the resting motor threshold at 1 Hz in three 500-pulse blocks, separated by 10-minute breaks for 1500 pulses total. The placebo coil produces the same noise and movement as an active coil, but doesn't deliver any magnetic stimulation.

Transcranial magnetic stimulation - Active Arm

An active TMS coil is used.

Group Type ACTIVE_COMPARATOR

Transcranial magnetic stimulation - Active Arm

Intervention Type DEVICE

Each seizure patient (subject) will receive 5 days in a row of active magnetic stimulation using the active TMS coil of the STM9000 Transcranial Magnetic Stimulator. This involves magnetic stimulation at 90% of the resting motor threshold at 1 Hz in three 500-pulse blocks, separated by 10-minute breaks for 1500 pulses total.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Transcranial magnetic stimulation - Placebo Arm

Each seizure patient (subject) will receive 5 days in a row the placebo (sham) magnetic stimulation using the placebo (sham) coil of the STM9000 Transcranial Magnetic Stimulator. This involves magnetic stimulation at 90% of the resting motor threshold at 1 Hz in three 500-pulse blocks, separated by 10-minute breaks for 1500 pulses total. The placebo coil produces the same noise and movement as an active coil, but doesn't deliver any magnetic stimulation.

Intervention Type DEVICE

Transcranial magnetic stimulation - Active Arm

Each seizure patient (subject) will receive 5 days in a row of active magnetic stimulation using the active TMS coil of the STM9000 Transcranial Magnetic Stimulator. This involves magnetic stimulation at 90% of the resting motor threshold at 1 Hz in three 500-pulse blocks, separated by 10-minute breaks for 1500 pulses total.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

STM9000 Transcranial Magnetic Stimulator

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Failure of adequate seizure control with prior use of at least 2 anti-seizure drugs.
2. at least one clearly identified and localizable likely seizure onset focus, as defined by the discharges (typically epileptiform spikes) and as identified by dEEG assessment through one or more routine clinical dEEG evaluations. This focus must be 2 to 3 cm from the head surface (to be reachable by TMS). Where multiple spike foci are present and meet these criteria, then the focus with either clinically relevant symptoms or the most spikes (or both) will be chosen as the target for treatment.
3. two or more partial seizures, with or without secondary generalization, in the last month, but less than 10 seizures per day.
4. Anti-seizure drug regimen has remained unchanged for the month before study entry, and there is reasonable likelihood of stability for the duration of the study, with the exception of allowing short-term rescue medications, such as lorazepam.
5. a history of epilepsy for at least 2 years.
6. age of 22 years and older.

Exclusion Criteria

1. If of childbearing potential, the patient must agree to use an effective method of birth control during the study and cease participation if pregnant.
2. Nursing mothers are excluded.
3. A history or condition of progressive brain disorders, serious systemic diseases, symptomatic cerebrovascular disease, cardiac disease, or alcohol abuse. Special conditions, for example, non-malignant brain tumors and vascular malformations, can be considered for entry on a case-by-case basis. Patients are not excluded on the basis of previous psychiatric hospitalizations or suicide attempts.
4. A history or condition of (generalized) status epilepticus or psychogenic seizures.
5. Presence of a cardiac pacemaker, vagus nerve stimulator, or metal implantation in the body (other than the teeth) including neurostimulators, cochlear implants, and implanted medication pumps.
6. Previous surgery involving opening the skull.
7. Unable to express presence of pain or discomfort.
Minimum Eligible Age

22 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Stanford University

OTHER

Sponsor Role collaborator

Electrical Geodesics, Inc.

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Robert S Fisher, Ph.D.

Role: PRINCIPAL_INVESTIGATOR

Stanford University

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

IDEG150216

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

TMS With Real-time E-field and EEG Source Imaging
NCT06645613 NOT_YET_RECRUITING NA